The repeatability of an intraoral dental colorimeter

被引:134
作者
Tung, FF
Goldstein, GR
Jang, S
Hittelman, E
机构
[1] NYU, Coll Dent, Div Restorat & Prosthodont Sci, Adv Educ Program Prosthodont, New York, NY 10010 USA
[2] NYU, Coll Dent, Dept Epidemiol & Hlth Promot, New York, NY 10010 USA
关键词
D O I
10.1067/mpr.2002.129803
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Characterizing and reproducing color remain one of the most challenging aspects of dentistry. A relatively new intraoral colorimeter measures the color of natural teeth and metal-ceramic restorations and prints out a color recipe for the Vintage Halo Porcelain System. The reliability of the colorimeter is unknown. Purpose. The purpose of this study was to evaluate the reliability of a contact dental colorimeter and to correlate the shade registered by the colorimeter with the shade selected by experienced clinicians. Material and methods. In part I of the study, 2 examiners (A and B) took 2 colorimeter measurements from the maxillary right central incisors of 11 subjects. The examiners were blinded to their own data and those of other investigators. The readings were repeated 3 weeks later with the same protocol. The Cronbach a reliability coefficient was used to analyze the collected data. In part II of the study, 2 experienced clinicians (examiners D and E) selected a shade from the classic Vita Lumin Vacuum shade guide for the maxillary right central incisors of the same 11 subjects. The clinicians were blinded to each other's selections and the colorimeter readings. It should be noted that the manufacturer of the colorimeter uses the terms shade, value, and hue to represent chroma, value, and hue, respectively, as defined in the Glossary of Prosthodontic Terms (J Prosthet Dent 1999;81: 39-110). Results. T he reliability analysis results for each of the combined trials for shade, value, and hue were all >.94. The interexaminer reliability a values were >.9 for shade and value and .64 to .74 for hue. The interexaminer a represented the value range of each of 4 measurements. The intraexaminer reliability a values for shade, value, and hue were .99, .95, and .96 for examiner A and .99, .93, and .97 for examiner B, respectively. In part II of the study, the colorimeter agreed with itself 82% of the time, whereas clinicians agreed with each other on the selected shade 73% of the time. Selections made by the colorimeter and the clinicians matched 55% to 64% of the time. Conclusion. Within the limitations of this study, the colorimeter reliably measured the color of natural teeth.
引用
收藏
页码:585 / 590
页数:6
相关论文
共 29 条
[1]   THE CONVERSION OF CHROMASCAN DESIGNATIONS TO CIE TRISTIMULUS VALUES [J].
BANGTSON, LK ;
GOODKIND, RJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1982, 48 (05) :610-617
[2]  
Berns RS, 2000, BILLMEYER SALTZMANS, P31
[3]   A COMPARATIVE STUDY OF SHADE-MATCHING PROCEDURES [J].
CULPEPPER, WD .
JOURNAL OF PROSTHETIC DENTISTRY, 1970, 24 (02) :166-+
[4]   Predicting porcelain thickness required for dental shade matches [J].
Douglas, RD ;
Przybylska, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (02) :143-149
[5]   REPEATABILITY OF A SPECIALLY DESIGNED INTRAORAL COLORIMETER [J].
GOLDSTEIN, GR ;
SCHMITT, GW .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06) :616-619
[6]   USE OF A FIBEROPTIC COLORIMETER FOR INVIVO COLOR MEASUREMENTS OF 2830 ANTERIOR TEETH [J].
GOODKIND, RJ ;
SCHWABACHER, WB .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 58 (05) :535-542
[7]  
HUNTER RS, 1987, MEASUREMENT APPEARAN, P1
[8]   ASSESSMENT OF APPEARANCE MATCH BY VISUAL OBSERVATION AND CLINICAL COLORIMETRY [J].
JOHNSTON, WM ;
KAO, EC .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (05) :819-822
[9]  
KATO T, 1984, QUINTESSENCE DENT TE, V8, P559
[10]   INSTRUMENTAL COLOR MEASUREMENT OF VITAL AND EXTRACTED HUMAN-TEETH [J].
MACENTEE, M ;
LAKOWSKI, R .
JOURNAL OF ORAL REHABILITATION, 1981, 8 (03) :203-208