THE IN VITRO EFFECT OF DIFFERENT IMPLANT ANGULATIONS AND CYCLIC DISLODGEMENT ON THE RETENTIVE PROPERTIES OF AN OVERDENTURE ATTACHMENT SYSTEM

被引:63
作者
Al-Ghafli, Suhail Ali [1 ,3 ]
Michalakis, Konstantinos X. [1 ,2 ]
Hirayama, Hiroshi
Kang, Kiho [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Operat Dent & Prosthodont, Div Grad & Postgrad Prosthodont, Boston, MA 02111 USA
[2] Aristotle Univ Thessaloniki, Sch Dent, Dept Removable Prosthodont, GR-54006 Thessaloniki, Greece
[3] Tawam Hosp, Al Ain, U Arab Emirates
关键词
MANDIBULAR OVERDENTURES; PROSTHETIC ASPECTS; PATIENT SATISFACTION; ORAL IMPLANTS; EXPERIENCE; FORCES; 5-YEAR;
D O I
10.1016/S0022-3913(09)60134-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The retentive capacity of ball attachments may be altered by a change in implant angulations. Purpose. The purpose of this in vitro study was to investigate the effect of cyclic dislodgement on the retention of an overdenture attachment system when 2 Implants were placed at angulations of 0, 5, 10, 15, and 20 degrees. Material and methods. Twelve acrylic resin blocks were fabricated and divided into 6 groups of 2 pairs each. In each of the 6 groups, 1 acrylic resin block was used to house the implants (block A), while the other (block B) was used to house the overdenture attachments. Two implants positioned at 0/0 degrees, with a standard plastic component (white) designed for 0-degree angulations, served as a control (CTRL), while the other 5 pairs of implants were placed in 5 different angulations: OD: 0/0 degrees, 5D: 5/5 degrees, 10D: 10/10 degrees, 15D: 15/15 degrees, 20D: 20/20 degrees (n=5). The extended range (green color) attachment was used for all groups except the control group. Implants (4.3 mm x 13 mm, internally hexed) were placed in blocks B. All angled implants were mesially tilted. Thirty pairs of attachments (Locator) were used. Dislodging cycles were applied to the overdenture attachment system. The Initial retentive forces among the groups were not identical. The cycles required for the retentive forces of the attachments to decrease from the initial values to 60 N, and then to 40 N and 20 N, were recorded for standardization purposes. One-way ANOVA and Tukey HSD tests were used to analyze the difference in retention loss among the 6 groups (alpha=.05). A regression analysis (alpha=.05) was also performed to investigate the relationship between the implant angulation, the retentive force, and the logarithm of the number of cycles required for ball attachment retention decrease. Results. The 1-way AN OVA and the Tu key HSD tests revealed significant differences for the number of cycles required by different implant angulation groups for the initial retentive values to decrease to 60 N, 40 N, and 20 N (P<.001). The 0D and 5D groups required the longest time for retention loss, while 20D and CTRL groups demonstrated the shortest time for retention loss. The results of the regression analysis of the logarithmic number of cycles on retentive force and implant angulation demonstrated a significant effect (P<.001). Conclusions. Implant angulations negatively affect attachment retention longevity. (J Prosthet Dent 2009;102:140147)
引用
收藏
页码:140 / 147
页数:8
相关论文
共 32 条
  • [11] Gamborena JI, 1997, INT J PROSTHODONT, V10, P123
  • [12] Gotfredsen K, 2000, INT J PROSTHODONT, V13, P125
  • [13] Gulizio Michael P, 2005, J Prosthodont, V14, P3, DOI 10.1111/j.1532-849X.2005.00005.x
  • [14] Jemt T, 1996, Int J Oral Maxillofac Implants, V11, P291
  • [15] TREATMENT OF THE MANDIBULAR COMPROMISED RIDGE - A LITERATURE-REVIEW
    JENNINGS, DE
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (05) : 579 - 579
  • [16] PROSTHETIC ASPECTS OF OSSEOINTEGRATED FIXTURES SUPPORTING OVERDENTURES - A 4-YEAR REPORT
    NAERT, I
    QUIRYNEN, M
    THEUNIERS, G
    VANSTEENBERGHE, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (05) : 671 - 680
  • [17] Naert I, 2004, INT J PROSTHODONT, V17, P401
  • [18] A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction
    Naert, I
    Gizani, S
    Vuylsteke, M
    Van Steenberghe, D
    [J]. JOURNAL OF ORAL REHABILITATION, 1999, 26 (03) : 195 - 202
  • [19] RETENTION FORCES OF SPHERICAL ATTACHMENTS AS A FUNCTION OF IMPLANT AND MATRIX ANGULATION IN MANDIBULAR OVERDENTURES: AN IN VITRO STUDY
    Ortegon, Sergio M.
    Thompson, Geoffrey A.
    Agar, John R.
    Taylor, Thomas D.
    Perdikis, Dimitri
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (04) : 231 - 238
  • [20] Petropoulos VC, 2002, INT J ORAL MAX IMPL, V17, P526