Numerical Simulation of Blood Flows in Patient-specific Abdominal Aorta with Primary Organs

被引:17
作者
Qin, Shanlin [1 ]
Chen, Rongliang [1 ,3 ]
Wu, Bokai [1 ]
Shiu, Wen-Shin [1 ]
Cai, Xiao-Chuan [2 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
[2] Univ Macau, Dept Math, Macau, Peoples R China
[3] Shenzhen Key Lab Exascale Engn & Sci Comp, Shenzhen, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Computational hemodynamics; Blood flow simulations; Abdominal aorta with primary organs; Finite element; Parallel computing; COMPUTATIONAL FLUID-DYNAMICS; OUTFLOW BOUNDARY-CONDITIONS; LOCAL SHEAR STRESSES; 3-DIMENSIONAL ULTRASOUND; HEMODYNAMICS; ANEURYSM; PRESSURE; ARTERY; CFD; QUANTIFICATION;
D O I
10.1007/s10237-021-01419-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The abdominal aorta is the largest artery in the abdominal cavity that supplies blood flows to vital organs through the complex visceral arterial branches, including the celiac trunk (the liver, stomach, spleen, etc.), the renal arteries (the kidneys) and the superior and inferior mesenteric arteries (the small and large intestine, pancreas, etc.). An accurate simulation of blood flows in this network of arteries is important for the understanding of the hemodynamics in various organs of healthy and diseased patients, but the computational cost is very high. As a result, most researchers choose to focus on a portion of the artery or use a low-dimensional approximation of the artery. In the present work, we introduce a parallel algorithm for the modeling of pulsatile flows in the abdominal aorta with branches to the primary organs, and an organ-based two-level method for calculating the resistances for the outflow boundary conditions. With this highly parallel approach, the simulation of the blood flow for a cardiac cycle of the anatomically detailed aorta can be obtained within a few hours, and the blood distribution to organs including liver, spleen and kidneys are also computed with certain accuracy. Moreover, we discuss the significant hemodynamic differences resulted from the influence of the peripheral branches. In addition, we examine the accuracy of the results with respect to the mesh size and time-step size and show the high parallel scalability of the proposed algorithm with up to 3000 processor cores.
引用
收藏
页码:909 / 924
页数:16
相关论文
共 55 条
[51]   Hepatic Vascular Flow Measurements by Phase Contrast MRI and Doppler Echography: A Comparative and Reproducibility Study [J].
Yzet, Thierry ;
Bouzerar, Roger ;
Allart, Jean-Dominique ;
Demuynck, Fabien ;
Legallais, Cecile ;
Robert, Brice ;
Deramond, Herve ;
Meyer, Marc-Etienne ;
Baledent, Olivier .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) :579-588
[52]   Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound [J].
Zhang, J. ;
Critchley, L. A. H. ;
Huang, L. .
BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) :392-402
[53]   Dynamic pressure-flow relationship of the cerebral circulation during acute increase in arterial pressure [J].
Zhang, Rong ;
Behbehani, Khosrow ;
Levine, Benjamin D. .
JOURNAL OF PHYSIOLOGY-LONDON, 2009, 587 (11) :2567-2577
[54]   Cardiovascular flow simulation at extreme scale [J].
Zhou, Min ;
Sahni, Onkar ;
Kim, H. Jin ;
Figueroa, C. Alberto ;
Taylor, Charles A. ;
Shephard, Mark S. ;
Jansen, Kenneth E. .
COMPUTATIONAL MECHANICS, 2010, 46 (01) :71-82
[55]   A review on low-dimensional physics-based models of systemic arteries: application to estimation of central aortic pressure [J].
Zhou, Shuran ;
Xu, Lisheng ;
Hao, Liling ;
Xiao, Hanguang ;
Yao, Yang ;
Qi, Lin ;
Yao, Yudong .
BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)