Anatomic considerations of costotransverse screw placement in the thoracic spine

被引:14
作者
Xu, RM
Ebraheim, NA
Ou, YJ
Skie, M
Yeasting, RA
机构
[1] Med Coll Ohio, Dept Orthopaed Surg, Toledo, OH 43699 USA
[2] Med Coll Ohio, Dept Anat, Toledo, OH 43699 USA
来源
SURGICAL NEUROLOGY | 2000年 / 53卷 / 04期
关键词
thoracic spine; costotransverse joint; screw fixation;
D O I
10.1016/S0090-3019(00)00203-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND Numerous techniques have been reported to restore spinal stability and to correct spinal deformities, including rods with wires/hooks, and rods or plates with pedicular screws. It was thought that posterior fixation of the thoracic spine through the costotransverse joint may be another alternative. METHODS Nine cadavers were obtained for study of screw fixation of the costotransverse joint for posterior thoracic instrumentation. The entrance point for screw insertion was designed to be at the posterior center of the clubbed extremity of the transverse process. From this point, a 3-mm drill bit was used to create the screw path penetrating the costotransverse joint and the ventral cortex of the rib. Under direct visualization of the costotransverse joint, the drill bit was directed parallel to the sagittal plane and toward the upper portion of the rib. Measurements included the screw path length and sagittal angulation. Also, the distance between the superior borders of the transverse process and the tubercle of the rib and the anatomic relationship of the drill bit exit to the intercostal vessels and nerves were evaluated. RESULTS The maximum length of the screw path was found at T1 (19.7 mm), whereas the minimum length was noted at T4-T5 (13.9 mm), This value decreased gradually from T1 to T4-T5, and slightly increased to T10. The larger sagittal angles of the screw path were found at the levels of T1-T4 (78-86 degrees), whereas the smaller were noted at the levels below T5 (53-61 degrees). The mean distance between the superior borders of the transverse process and the tubercle of the rib was smaller at T1-T5 (0.2-0.4 mm), and significantly increased to T8 (5.1 mm), and then slightly decreased to T10, The variation of this parameter was remarkable. All of the exit points for the drill bit were located in the upper half of the rib, and away from the intercostal vessels. CONCLUSIONS The ideal screw orientation is parallel to the sagittal plane, and angled 80-90 degrees relative to the frontal plane for T1-T4 and 50-70 degrees for T5-T10 superiorly starting at the posterior center of the transverse process. Costotransverse screw fixation in the thoracic spine may be an alternative to pre-existing methods. (C) 2000 by Elsevier Science Inc.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 16 条
[1]   SCHEUERMANNS KYPHOSIS - RESULTS OF SURGICAL TREATMENT BY POSTERIOR SPINE ARTHRODESIS IN 22 PATIENTS [J].
BRADFORD, DS ;
MOE, JH ;
MONTALVO, FJ ;
WINTER, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (04) :439-448
[2]  
COTREL Y, 1988, CLIN ORTHOP RELAT R, P10
[3]  
DENIS F, 1988, ORTHOP CLIN N AM, V19, P291
[4]   HARRINGTON INSTRUMENTATION AND SPINE FUSION FOR UNSTABLE FRACTURES AND FRACTURE-DISLOCATIONS OF THORACIC AND LUMBAR SPINE [J].
FLESCH, JR ;
LEIDER, LL ;
ERICKSON, DL ;
CHOU, SN ;
BRADFORD, DS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :143-153
[5]  
Harrington P R, 1972, Orthop Clin North Am, V3, P49
[6]   Pedicle and transverse process screws of the upper thoracic spine - Biomechanical comparison of loads to failure [J].
Heller, JG ;
Shuster, JK ;
Hutton, WC .
SPINE, 1999, 24 (07) :654-658
[7]  
JACOBS RR, 1984, CLIN ORTHOP RELAT R, V189, P168
[8]  
KRAG MH, 1986, CLIN ORTHOP RELAT R, V203, P75
[9]   SURGICAL-TREATMENT OF TUMORS OF THE SPINE [J].
LEE, CK ;
ROSA, R ;
FERNAND, R .
SPINE, 1986, 11 (03) :201-208
[10]  
STENER B, 1971, Journal of Bone and Joint Surgery British Volume, V53, P278