Vibration analysis of membrane by time average in-line digital holographic interferometry

被引:0
作者
Singh, Vijay Raj [1 ]
Asundi, Anand [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2 | 2006年 / 326-328卷
关键词
in-line digital holography; time average method; numerical reconstruction; CCD; mean deformation; mixing of fringes;
D O I
10.4028/www.scientific.net/KEM.326-328.23
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this paper, in-line digital holography is combined with time average method and applied for vibration analysis of an aluminum membrane. The numerically reconstructed wave from time average holograms contains information of mode shape and mean deformation of the vibrating objects. At lower amplitudes of vibration only the deformation fringes are observed and as the amplitude is increases, the Bessel fringes representing the time average vibration amplitude also become visible. Experimental results for a 10mm size membrane are presented.
引用
收藏
页码:23 / +
页数:2
相关论文
共 12 条
  • [1] Time-averaged in-line digital holographic interferometry for vibration analysis
    Asundi, A
    Singh, VR
    [J]. APPLIED OPTICS, 2006, 45 (11) : 2391 - 2395
  • [2] Sectioning of amplitude images in digital holography
    Asundi, A
    Singh, VR
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (01) : 75 - 78
  • [3] A digital holographic microscope for complete characterization of microelectromechanical systems
    Coppola, G
    Ferraro, P
    Iodice, M
    De Nicola, S
    Finizio, A
    Grilli, S
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (03) : 529 - 539
  • [4] Detection of hidden stationary deformations of vibrating surfaces by use of time-averaged digital holographic interferometry
    Demoli, N
    Vukicevic, D
    [J]. OPTICS LETTERS, 2004, 29 (20) : 2423 - 2425
  • [5] Goodman J W, 1996, INTRO FOURIER OPTICS
  • [6] Suppression of the dc term in digital holography
    Kreis, TM
    Juptner, WPO
    [J]. OPTICAL ENGINEERING, 1997, 36 (08) : 2357 - 2360
  • [7] Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy
    Marquet, P
    Rappaz, B
    Magistretti, PJ
    Cuche, E
    Emery, Y
    Colomb, T
    Depeursinge, C
    [J]. OPTICS LETTERS, 2005, 30 (05) : 468 - 470
  • [8] Some opportunities for vibration analysis with time averaging in digital Fresnel holography
    Picart, P
    Leval, J
    Mounier, D
    Gougeon, S
    [J]. APPLIED OPTICS, 2005, 44 (03) : 337 - 343
  • [9] Time-averaged digital holography
    Picart, P
    Leval, J
    Mounier, D
    Gougeon, S
    [J]. OPTICS LETTERS, 2003, 28 (20) : 1900 - 1902
  • [10] DIRECT RECORDING OF HOLOGRAMS BY A CCD TARGET AND NUMERICAL RECONSTRUCTION
    SCHNARS, U
    JUPTNER, W
    [J]. APPLIED OPTICS, 1994, 33 (02): : 179 - 181