CLINICAL USE OF 3-D IMAGE REGISTRATION

被引:0
作者
Remeijer, Peter [1 ]
机构
[1] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
来源
RADIOTHERAPY AND BRACHYTHERAPY | 2009年
关键词
DICOM; image registration; CT; MRI; PET; cost functions; grey value registration; chamfer matching; MR-IMAGES; BRAIN;
D O I
10.1007/978-90-481-3097-9_11
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Using DICOM it has become much easier to exchange images between different manufacturer's equipment, which is essential to clinically implement image registration. Therefore, first a simple introduction to DICOM will be given, in which the advantages of DICOM and some of its deficiencies are explained. Image registration algorithms can be grouped in two main categories: volume registration and chamfer matching algorithms. The merits and drawbacks of both possibilities will be discussed.
引用
收藏
页码:127 / +
页数:8
相关论文
共 8 条
  • [1] An automatic registration method for frameless stereotaxy, image guided surgery, and enhanced reality visualization
    Grimson, WEL
    Ettinger, GJ
    White, SJ
    LozanoPerez, T
    Wells, WM
    Kikinis, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) : 129 - 140
  • [2] A REGISTRATION AND INTERPOLATION PROCEDURE FOR SUBVOXEL MATCHING OF SERIALLY ACQUIRED MR-IMAGES
    HAJNAL, JV
    SAEED, N
    SOAR, EJ
    OATRIDGE, A
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (02) : 289 - 296
  • [3] Medical image registration
    Hill, DLG
    Batchelor, PG
    Holden, M
    Hawkes, DJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) : R1 - R45
  • [4] IMAGE FUSION FOR STEREOTAXIC RADIOTHERAPY AND RADIOSURGERY TREATMENT PLANNING
    KOOY, HM
    VANHERK, M
    BARNES, PD
    ALEXANDER, E
    DUNBAR, SF
    TARBELL, NJ
    MULKERN, RV
    HOLUPKA, EJ
    LOEFFLER, JS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1229 - 1234
  • [5] Multimodality image registration by maximization of mutual information
    Maes, F
    Collignon, A
    Vandermeulen, D
    Marchal, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 187 - 198
  • [6] FAST NONSUPERVISED 3D REGISTRATION OF PET AND MR-IMAGES OF THE BRAIN
    MANGIN, JF
    FROUIN, V
    BLOCH, I
    BENDRIEM, B
    LOPEZKRAHE, J
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (05) : 749 - 762
  • [7] Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    Studholme, C
    Hill, DLG
    Hawkes, DJ
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 25 - 35
  • [8] AUTOMATIC 3-DIMENSIONAL CORRELATION OF CT-CT, CT-MRI, AND CT-SPECT USING CHAMFER MATCHING
    VANHERK, M
    KOOY, HM
    [J]. MEDICAL PHYSICS, 1994, 21 (07) : 1163 - 1178