Microfluidic electrical impedance assessment of red blood cell-mediated microvascular occlusion

被引:31
|
作者
Man, Yuncheng [1 ]
Maji, Debnath [2 ]
An, Ran [1 ]
Ahuja, Sanjay P. [3 ]
Little, Jane A. [4 ]
Suster, Michael A. [2 ]
Mohseni, Pedram [2 ,5 ]
Gurkan, Umut A. [1 ,5 ,6 ]
机构
[1] Case Western Reserve Univ, Mech & Aerosp Engn Dept, 10900 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Elect Comp & Syst Engn Dept, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Rainbow Babies & Childrens Hosp, Div Hematol & Oncol, Cleveland, OH 44106 USA
[4] Univ North Carolina Chapel Hill, Dept Med, Div Hematol & Oncol, UNC Blood Res Ctr, Chapel Hill, NC 27599 USA
[5] Case Western Reserve Univ, Dept Biomed Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Case Comprehens Canc Ctr, 10900 Euclid Ave, Cleveland, OH 44106 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
HEREDITARY SPHEROCYTOSIS; MEAN SHIFT; DEFORMABILITY; MEMBRANE; DISEASE; FLOW; MALARIA; PERFUSION; ADHESION; PATIENT;
D O I
10.1039/d0lc01133a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alterations in the deformability of red blood cells (RBCs), occurring in hemolytic blood disorders such as sickle cell disease (SCD), contribute to vaso-occlusion and disease pathophysiology. There are few functional in vitro assays for standardized assessment of RBC-mediated microvascular occlusion. Here, we present the design, fabrication, and clinical testing of the Microfluidic Impedance Red Cell Assay (MIRCA) with embedded capillary network-based micropillar arrays and integrated electrical impedance measurement electrodes to address this need. The micropillar arrays consist of microcapillaries ranging from 12 mu m to 3 mu m, with each array paired with two sputtered gold electrodes to measure the impedance change of the array before and after sample perfusion through the microfluidic device. We define RBC occlusion index (ROI) and RBC electrical impedance index (REI), which represent the cumulative percentage occlusion and cumulative percentage impedance change, respectively. We demonstrate the promise of MIRCA in two common red cell disorders, SCD and hereditary spherocytosis. We show that the electrical impedance measurement reflects the microvascular occlusion, where REI significantly correlates with ROI that is obtained via high-resolution microscopy imaging of the microcapillary arrays. Further, we show that RBC-mediated microvascular occlusion, represented by ROI and REI, associates with clinical treatment outcomes and correlates with in vivo hemolytic biomarkers, lactate dehydrogenase (LDH) level and absolute reticulocyte count (ARC) in SCD. Impedance measurement obviates the need for high-resolution imaging, enabling future translation of this technology for widespread access, portable and point-of-care use. Our findings suggest that the presented microfluidic design and the integrated electrical impedance measurement provide a reproducible functional test for standardized assessment of RBC-mediated microvascular occlusion. MIRCA and the newly defined REI may serve as an in vitro therapeutic efficacy benchmark for assessing the clinical outcome of emerging RBC-modifying targeted and curative therapies.
引用
收藏
页码:1036 / 1048
页数:13
相关论文
共 50 条
  • [31] Flow of Red Blood Cells through a microfluidic extensional device: An image analysis assessment
    Yaginuma, T.
    Pereira, A. I.
    Rodrigues, P. J.
    Lima, R.
    Oliveira, M. S. N.
    Ishikawa, T.
    Yamaguchi, T.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: VIPIMAGE 2011, 2012, : 217 - 220
  • [32] Assessment of red blood cell deformability by centrifugal sedimentation
    Albalak, A
    Streichman, S
    Marmur, A
    CHEMICAL ENGINEERING COMMUNICATIONS, 1996, 153 : 5 - 15
  • [33] Cell-free layer development and spatial organization of healthy and rigid red blood cells in a microfluidic bifurcation
    Rashidi, Yazdan
    Aouane, Othmane
    Darras, Alexis
    John, Thomas
    Harting, Jens
    Wagner, Christian
    Recktenwald, Steffen M.
    SOFT MATTER, 2023, 19 (33) : 6255 - 6266
  • [34] Assessment of Red Blood Cell Aggregation in Preeclampsia by Microfluidic Image Flow Analysis-Impact of Oxidative Stress on Disease Severity
    Alexandrova-Watanabe, Anika
    Abadjieva, Emilia
    Giosheva, Ina
    Langari, Ariana
    Tiankov, Tihomir
    Gartchev, Emil
    Komsa-Penkova, Regina
    Todinova, Svetla
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (07)
  • [35] Measuring red blood cell deformability and its heterogeneity using a fast microfluidic device
    Kumari, Savita
    Mehendale, Ninad
    Roy, Tanusri
    Sen, Shamik
    Mitra, Dhrubaditya
    Paul, Debjani
    CELL REPORTS PHYSICAL SCIENCE, 2024, 5 (08):
  • [36] Association between red blood cell distribution width and macrovascular and microvascular complications in diabetes
    Malandrino, N.
    Wu, W. C.
    Taveira, T. H.
    Whitlatch, H. B.
    Smith, R. J.
    DIABETOLOGIA, 2012, 55 (01) : 226 - 235
  • [37] A Comparative Study of Image Processing Methods for the Assessment of the Red Blood Cells Deformability in a Microfluidic Device
    Faustino, Vera
    Catarino, Susana O.
    Pinho, Diana
    Minas, Graca
    Lima, Rui
    VIPIMAGE 2017, 2018, 27 : 923 - 929
  • [38] Development and regulation of cell-mediated immuneresponses to the blood stages of malaria: Implications for vaccine research
    Good, MF
    Xu, HJ
    Wykes, M
    Engwerda, CR
    ANNUAL REVIEW OF IMMUNOLOGY, 2005, 23 : 69 - 99
  • [39] Red blood cells aggregability measurement of coagulating blood in extracorporeal circulation system with multiple-frequency electrical impedance spectroscopy
    Li, Jianping
    Sapkota, Achyut
    Kikuchi, Daisuke
    Sakota, Daisuke
    Maruyama, Osamu
    Takei, Masahiro
    BIOSENSORS & BIOELECTRONICS, 2018, 112 : 79 - 85
  • [40] Microfluidic experimental setup for adhesion and recovery measurements of red blood cells in sickle cell disease
    Partola, Kostyantyn R.
    Andemariam, Biree
    Lykotrafitis, George
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 80 - 84