Microfluidic electrical impedance assessment of red blood cell-mediated microvascular occlusion

被引:31
|
作者
Man, Yuncheng [1 ]
Maji, Debnath [2 ]
An, Ran [1 ]
Ahuja, Sanjay P. [3 ]
Little, Jane A. [4 ]
Suster, Michael A. [2 ]
Mohseni, Pedram [2 ,5 ]
Gurkan, Umut A. [1 ,5 ,6 ]
机构
[1] Case Western Reserve Univ, Mech & Aerosp Engn Dept, 10900 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Elect Comp & Syst Engn Dept, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Rainbow Babies & Childrens Hosp, Div Hematol & Oncol, Cleveland, OH 44106 USA
[4] Univ North Carolina Chapel Hill, Dept Med, Div Hematol & Oncol, UNC Blood Res Ctr, Chapel Hill, NC 27599 USA
[5] Case Western Reserve Univ, Dept Biomed Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Case Comprehens Canc Ctr, 10900 Euclid Ave, Cleveland, OH 44106 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
HEREDITARY SPHEROCYTOSIS; MEAN SHIFT; DEFORMABILITY; MEMBRANE; DISEASE; FLOW; MALARIA; PERFUSION; ADHESION; PATIENT;
D O I
10.1039/d0lc01133a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alterations in the deformability of red blood cells (RBCs), occurring in hemolytic blood disorders such as sickle cell disease (SCD), contribute to vaso-occlusion and disease pathophysiology. There are few functional in vitro assays for standardized assessment of RBC-mediated microvascular occlusion. Here, we present the design, fabrication, and clinical testing of the Microfluidic Impedance Red Cell Assay (MIRCA) with embedded capillary network-based micropillar arrays and integrated electrical impedance measurement electrodes to address this need. The micropillar arrays consist of microcapillaries ranging from 12 mu m to 3 mu m, with each array paired with two sputtered gold electrodes to measure the impedance change of the array before and after sample perfusion through the microfluidic device. We define RBC occlusion index (ROI) and RBC electrical impedance index (REI), which represent the cumulative percentage occlusion and cumulative percentage impedance change, respectively. We demonstrate the promise of MIRCA in two common red cell disorders, SCD and hereditary spherocytosis. We show that the electrical impedance measurement reflects the microvascular occlusion, where REI significantly correlates with ROI that is obtained via high-resolution microscopy imaging of the microcapillary arrays. Further, we show that RBC-mediated microvascular occlusion, represented by ROI and REI, associates with clinical treatment outcomes and correlates with in vivo hemolytic biomarkers, lactate dehydrogenase (LDH) level and absolute reticulocyte count (ARC) in SCD. Impedance measurement obviates the need for high-resolution imaging, enabling future translation of this technology for widespread access, portable and point-of-care use. Our findings suggest that the presented microfluidic design and the integrated electrical impedance measurement provide a reproducible functional test for standardized assessment of RBC-mediated microvascular occlusion. MIRCA and the newly defined REI may serve as an in vitro therapeutic efficacy benchmark for assessing the clinical outcome of emerging RBC-modifying targeted and curative therapies.
引用
收藏
页码:1036 / 1048
页数:13
相关论文
共 50 条
  • [21] Analysis of red blood cell partitioning at bifurcations in simulated microvascular networks
    Balogh, Peter
    Bagchi, Prosenjit
    PHYSICS OF FLUIDS, 2018, 30 (05)
  • [22] Alterations in Red Blood Cell Deformability during Storage: A Microfluidic Approach
    Cluitmans, Judith C. A.
    Chokkalingam, Venkatachalam
    Janssen, Arno M.
    Brock, Roland
    Huck, Wilhelm T. S.
    Bosman, Giel J. C. G. M.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [23] Red Blood Cell Partitioning Using a Microfluidic Channel with Ladder Structure
    Hyakutake, Toru
    Tsutsumi, Yuya
    Miyoshi, Yohei
    Yasui, Manabu
    Mizuno, Tomoki
    Tateno, Mizuki
    MICROMACHINES, 2023, 14 (07)
  • [24] Assessment of the red blood cell proteome in a dog with unexplained hemolytic anemia
    Black, Victoria L.
    Heesom, Kate
    Whittington, Fran
    Davis, Sean
    Tasker, Severine
    Adamantos, Sophie
    Davidson, Andrew D.
    VETERINARY CLINICAL PATHOLOGY, 2018, 47 (03) : 377 - 385
  • [25] Concurrent Assessment of Deformability and Adhesiveness of Sickle Red Blood Cells by Measuring Perfusion of an Adhesive Artificial Microvascular Network
    Lu, Madeleine
    Kanne, Celeste K.
    Reddington, Riley C.
    Lezzar, Dalia L.
    Sheehan, Vivien A.
    Shevkoplyas, Sergey S.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [26] Dielectric characterization of Plasmodium falciparum-infected red blood cells using microfluidic impedance cytometry
    Honrado, C.
    Ciuffreda, L.
    Spencer, D.
    Ranford-Cartwright, L.
    Morgan, H.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2018, 15 (147)
  • [27] Characterization of red blood cell microcirculatory parameters using a bioimpedance microfluidic device
    Xu, Tieying
    Lizarralde-Iragorri, Maria A.
    Roman, Jean
    Ghasemi, Rasta
    Lefevre, Jean-Pierre
    Martincic, Emile
    Brousse, Valentine
    Francais, Olivier
    El Nemer, Wassim
    Le Pioufle, Bruno
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [28] Mechanical and Electrical Properties Characterization Towards Plant Cell Study Using Microfluidic Impedance Device
    Han, Ziyu
    Duan, Xuexin
    Chen, Lincai
    Wang, Jiehua
    Gao, Yunhua
    2018 IEEE SENSORS, 2018, : 1546 - 1548
  • [29] Relation between hematocrit partitioning and red blood cell lingering in a microfluidic network
    Bucciarelli, Aurelia
    Mantegazza, Alberto
    Haeberlin, Andreas
    Obrist, Dominik
    BIOPHYSICAL JOURNAL, 2024, 123 (19) : 3355 - 3365
  • [30] A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel
    Faustino, Vera
    Rodrigues, Raquel O.
    Pinho, Diana
    Costa, Elisio
    Santos-Silva, Alice
    Miranda, Vasco
    Amaral, Joana S.
    Lima, Rui
    MICROMACHINES, 2019, 10 (10)