Microfluidic electrical impedance assessment of red blood cell-mediated microvascular occlusion

被引:31
作者
Man, Yuncheng [1 ]
Maji, Debnath [2 ]
An, Ran [1 ]
Ahuja, Sanjay P. [3 ]
Little, Jane A. [4 ]
Suster, Michael A. [2 ]
Mohseni, Pedram [2 ,5 ]
Gurkan, Umut A. [1 ,5 ,6 ]
机构
[1] Case Western Reserve Univ, Mech & Aerosp Engn Dept, 10900 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Elect Comp & Syst Engn Dept, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Rainbow Babies & Childrens Hosp, Div Hematol & Oncol, Cleveland, OH 44106 USA
[4] Univ North Carolina Chapel Hill, Dept Med, Div Hematol & Oncol, UNC Blood Res Ctr, Chapel Hill, NC 27599 USA
[5] Case Western Reserve Univ, Dept Biomed Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Case Comprehens Canc Ctr, 10900 Euclid Ave, Cleveland, OH 44106 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
HEREDITARY SPHEROCYTOSIS; MEAN SHIFT; DEFORMABILITY; MEMBRANE; DISEASE; FLOW; MALARIA; PERFUSION; ADHESION; PATIENT;
D O I
10.1039/d0lc01133a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alterations in the deformability of red blood cells (RBCs), occurring in hemolytic blood disorders such as sickle cell disease (SCD), contribute to vaso-occlusion and disease pathophysiology. There are few functional in vitro assays for standardized assessment of RBC-mediated microvascular occlusion. Here, we present the design, fabrication, and clinical testing of the Microfluidic Impedance Red Cell Assay (MIRCA) with embedded capillary network-based micropillar arrays and integrated electrical impedance measurement electrodes to address this need. The micropillar arrays consist of microcapillaries ranging from 12 mu m to 3 mu m, with each array paired with two sputtered gold electrodes to measure the impedance change of the array before and after sample perfusion through the microfluidic device. We define RBC occlusion index (ROI) and RBC electrical impedance index (REI), which represent the cumulative percentage occlusion and cumulative percentage impedance change, respectively. We demonstrate the promise of MIRCA in two common red cell disorders, SCD and hereditary spherocytosis. We show that the electrical impedance measurement reflects the microvascular occlusion, where REI significantly correlates with ROI that is obtained via high-resolution microscopy imaging of the microcapillary arrays. Further, we show that RBC-mediated microvascular occlusion, represented by ROI and REI, associates with clinical treatment outcomes and correlates with in vivo hemolytic biomarkers, lactate dehydrogenase (LDH) level and absolute reticulocyte count (ARC) in SCD. Impedance measurement obviates the need for high-resolution imaging, enabling future translation of this technology for widespread access, portable and point-of-care use. Our findings suggest that the presented microfluidic design and the integrated electrical impedance measurement provide a reproducible functional test for standardized assessment of RBC-mediated microvascular occlusion. MIRCA and the newly defined REI may serve as an in vitro therapeutic efficacy benchmark for assessing the clinical outcome of emerging RBC-modifying targeted and curative therapies.
引用
收藏
页码:1036 / 1048
页数:13
相关论文
共 96 条
[1]   Microfluidics-Based Assessment of Cell Deformability [J].
Adamo, Andrea ;
Sharei, Armon ;
Adamo, Luigi ;
Lee, ByungKun ;
Mao, Shirley ;
Jensen, Klavs F. .
ANALYTICAL CHEMISTRY, 2012, 84 (15) :6438-6443
[2]   Dynamic deformability of sickle red blood cells in microphysiological flow [J].
Alapan, Y. ;
Matsuyama, Y. ;
Little, J. A. ;
Gurkan, U. A. .
TECHNOLOGY, 2016, 4 (02) :71-79
[3]   Sickle cell disease biochip: a functional red blood cell adhesion assay for monitoring sickle cell disease [J].
Alapan, Yunus ;
Kim, Ceonne ;
Adhikari, Anima ;
Gray, Kayla E. ;
Gurkan-Cavusoglu, Evren ;
Little, Jane A. ;
Gurkan, Umut A. .
TRANSLATIONAL RESEARCH, 2016, 173 :74-91
[4]   Heterogeneous Red Blood Cell Adhesion and Deformability in Sickle Cell Disease [J].
Alapan, Yunus ;
Little, Jane A. ;
Gurkan, Umut A. .
SCIENTIFIC REPORTS, 2014, 4
[5]  
An R., 2020, BLOOD, V136, P13
[6]   Spatially variant red blood cell crenation in alternating current non-uniform fields [J].
An, Ran ;
Wipf, David O. ;
Minerick, Adrienne R. .
BIOMICROFLUIDICS, 2014, 8 (02)
[7]   Comparison of three commercially available ektacytometers with different shearing geometries [J].
Baskurt, Oguz K. ;
Hardeman, M. R. ;
Uyuklu, Mehmet ;
Ulker, Pinar ;
Cengiz, Melike ;
Nemeth, Norbert ;
Shin, Sehyun ;
Alexy, Tamas ;
Meiselman, Herbert J. .
BIORHEOLOGY, 2009, 46 (03) :251-264
[8]   Perfusion Abnormalities in Children with Cerebral Malaria and Malarial Retinopathy [J].
Beare, Nicholas A. V. ;
Harding, Simon P. ;
Taylor, Terrie E. ;
Lewallen, Susan ;
Molyneux, Malcolm E. .
JOURNAL OF INFECTIOUS DISEASES, 2009, 199 (02) :263-271
[9]  
Bow H, 2011, LAB CHIP, V11, P1065, DOI [10.1039/c0lc00472c, 10.1039/c01c00472c]
[10]   The pathogenesis of Plasmodium falciparum malaria in humans: insights from splenic physiology [J].
Buffet, Pierre A. ;
Safeukui, Innocent ;
Deplaine, Guillaume ;
Brousse, Valentine ;
Prendki, Virginie ;
Thellier, Marc ;
Turner, Gareth D. ;
Mercereau-Puijalon, Odile .
BLOOD, 2011, 117 (02) :381-392