Determination of aromatic compounds in eluates of pyrolysis solid residues using HS-GC-MS and DLLME-GC-MS

被引:21
|
作者
Bernardo, Maria S. [1 ]
Goncalves, M. [1 ]
Lapa, N. [1 ]
Barbosa, R. [1 ]
Mendes, B. [1 ]
Pinto, F. [2 ]
Gulyurtlu, Ibrahim [1 ,2 ]
机构
[1] Univ Nova Lisboa, Fac Ciencias & Tecnol, P-2829516 Caparica, Portugal
[2] INETI DEECA, P-1649038 Lisbon, Portugal
关键词
Headspace; Solid phase microextraction; Eluates; Volatile aromatic hydrocarbons; Pyrolysis residues; LIQUID-LIQUID MICROEXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; PHASE MICROEXTRACTION; ORGANIC-COMPOUNDS; WATER; HEADSPACE; TOXICITY; VOLATILE; LEACHATES; LANDFILLS;
D O I
10.1016/j.talanta.2009.06.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of 15 aromatic hydrocarbons in eluates from solid residues produced during the co-pyrolysis of plastics and pine biomass was developed. In a first step, several sampling techniques (headspace solid phase microextraction (HS-SPME), static headspace sampling (HS), and dispersive liquid-liquid microextraction (DLLME) were compared in order to evaluate their sensitivity towards these analytes. HS-SPME and HS sampling had the better performance, but DLLME was itself as a technique able to extract volatiles with a significant enrichment factor. HS sampling coupled with GC-MS was chosen for method validation for the analytes tested. Calibration curves were constructed for each analyte with correlation coefficients higher than 0.999. The limits of detection were in the range of 0.66-37.85 ng/L The precision of the HS method was evaluated and good repeatability was achieved with relative standard deviations of 4.8-13.2% The recoveries of the analytes were evaluated by analysing fortified real eluate samples and were in the range of 60.6-113.9%. The validated method was applied in real eluate samples. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the compounds in higher concentrations. The DLLME technique coupled with GC-MS was used to investigate the presence of less volatile contaminants in eluate samples. This analysis revealed the presence of significant amounts of alkyl phenols and other aromatic compounds with appreciable water solubility. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 50 条
  • [21] Determination of different recreational drugs in hair by HS-SPME and GC/MS
    Merola, Gustavo
    Gentili, Stefano
    Tagliaro, Franco
    Macchia, Teodora
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (07) : 2987 - 2995
  • [22] DETERMINATION OF PESTICIDE RESIDUES IN BOVINE MILK USING A MODIFIED QuEChERS METHOD AND GC-MS/MS
    Bandeira, Danieli Daiani
    Munaretto, Juliana S.
    Rizzetti, Tiele M.
    Ferronato, Giovana
    Prestes, Osmar D.
    Martins, Manoel L.
    Zanella, Renato
    Adaime, Martha B.
    QUIMICA NOVA, 2014, 37 (05): : 900 - 907
  • [23] Residual solvents determination in pharmaceutical products by GC-HS and GC-MS-SPME
    Camarasu, CC
    Mezei-Szuts, M
    Varga, GB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) : 623 - 638
  • [24] METHOD VALIDATION FOR HS-SPME / GC-MS FOR DETERMINATION OF CARBARYL IN BLOOD PLASMA
    de Souza, Francisco Thiago C.
    Camelo, Andre Luiz M.
    Marques, Ricardo de Araujo
    Filho, Luiz Ivando Pires F.
    Pinheiro, Ronald F.
    Longhinotti, Elisane
    Becker, Helena
    QUIMICA NOVA, 2017, 40 (05): : 586 - 593
  • [25] Characteristic volatiles fingerprints and changes of volatile compounds in fresh and dried Tricholoma matsutake Singer by HS-GC-IMS and HS-SPME-GC-MS
    Guo, Yu
    Chen, Dong
    Dong, Yifei
    Ju, Huapeng
    Wu, Chuang
    Lin, Songyi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1099 : 46 - 55
  • [26] Rapid determination of volatile compounds in grapes by HS-SPME coupled with GC-MS
    Sánchez-Palomo, E
    Díaz-Maroto, MC
    Pérez-Coello, MS
    TALANTA, 2005, 66 (05) : 1152 - 1157
  • [27] Solid-Phase Microextraction Combined with GC-MS for Determination of Diquat and Paraquat Residues in Water
    Gao, Lina
    Liu, Junting
    Yuan, Huiya
    Deng, Xiaolan
    CHROMATOGRAPHIA, 2015, 78 (1-2) : 125 - 130
  • [28] DLLME-SFO-GC-MS procedure for the determination of 10 organochlorine pesticides in water and remediation using magnetite nanoparticles
    Rocha Carvalho, Rhiane Ramos
    Rodriguez Rodriguez, Mariandry Dela Valle
    Franco, Elton Santos
    Beltrame, Felipe
    Pereira, Alex Leite
    Santos, Vivian Silva
    Araujo, Wildo
    Rocha, Bruno Alves
    Rodrigues, Jairo Lisboa
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (36) : 45336 - 45348
  • [29] EI and NCI GC-MS and GC-MS/MS: Comparative Study of Performance Characteristics for the Determination of Pesticide Residues in Plant Matrix
    Anagnostopoulos, Chris
    Charalampous, Angeliki
    Balayiannis, George
    CHROMATOGRAPHIA, 2015, 78 (1-2) : 109 - 118
  • [30] Rapid Determination of Volatile Compounds in Gymnotheca involucrata Pei. by MAE-HS-SPME Followed by GC-MS
    Yang, Zai-bo
    Mao, Hai-li
    Kang, Wen-yi
    Zou, Hong-tao
    Sun, Cheng-bin
    Guo, Zhi-you
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2010, 87 (07) : 737 - 745