摘要
Background: Trabecular Metal (TM) is a new highly porous material made of tantalum (Zimmer, Warsaw, Indiana, USA). Its three-dimensional structure is composed of a series of interconnected dodecahedron pores that are on average 550 m in diameter. This size is considered optimal for bone ingrowth and is similar to trabecular bone. The elastic modulus of TM (3 GPa) is more similar to that of cancellous (0,1-1,5 GPa) or cortical (112-18 GPa) bone and is significantly less similar to that of Titanium (110 GPa) and Co-Cr alloys (220 GPa). These features enable bone apposition and remodeling. The purpose of the present study was to evaluate the histology of the bone-implant interface in a human specimen. Materials and Methods: A highly porous tantalum cup (Zimmer, Warsaw, Indiana, USA) was removed for recurrent dislocations three years after implantation. In order to obtain a slice of the cup, two cuts were made on the centre using an Exakt cutting machine. Then the slice was embedded in a Technovit resin and a Hematoxylin-eosin stain was used to study the bone tissue. Bone ingrowth was calculated using a method based on simple calculations of planar geometry. Results: The histological evaluation of the periprosthetic tissues revealed a typical chronic inflammation with few particles of polyethylene that were birefringent using polarized light. The quantitative evaluation of bone ingrowth revealed that more than 95 of voids were filled with bone. Discussion: In the literature, a lot of studies focused on tantalum were carried on animal model. Up to now little information is available about the histology of the bone-tantalum interface in a human artificial joint. We had an opportunity to remove a well integrated cup hence this study. The histology confirmed the strong relationship between the structure of this material and bone. The morphometric analysis revealed a high percentage of bone ingrowth.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [31] Finite Element Analysis of Humerus Bone for Cup Radious Variations
    Sharma, Neelesh K.
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (09) : 9450 - 9455
  • [32] BONE INGROWTH INTO POROUS FIBER TITANIUM IMPLANTS
    SOLHEIM, LF
    RONNINGEN, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (06): : 720 - 721
  • [33] Biomechanical assessment of bone ingrowth in porous hydroxyapatite
    Hing, KA
    Best, SM
    Tanner, KE
    Bonfield, W
    Revell, PA
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (12) : 731 - 736
  • [34] Bone ingrowth in macroporous Bonelike® for orthopaedic applications
    Gutierres, M.
    Lopes, M. A.
    Hussain, N. Sooraj
    Lemos, A. F.
    Ferreira, J. M. F.
    Afonso, A.
    Cabral, A. T.
    Almeida, L.
    Santos, J. D.
    ACTA BIOMATERIALIA, 2008, 4 (02) : 370 - 377
  • [35] Coarse Surface Microcavities Permit Bone Ingrowth and
    Anitua, Eduardo
    Tejero, Ricardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (02) : 289 - 301
  • [36] Bone ingrowth processes on porous metalic implants
    Bialystok Technical University, Faculty of Mechanical Engineering, Department of Materials Engineering and Mechanical Technology, Poland
    Solid State Phenomena, 2009, (776-781)
  • [37] GROWTH-FACTOR INDUCED BONE INGROWTH
    KELLER, JC
    GROTENDORST, GR
    STAYTON, LG
    HAUTANIEMI, J
    YOUNG, FA
    JOURNAL OF DENTAL RESEARCH, 1987, 66 : 114 - 114
  • [38] CLINICAL INDICATORS AND BONE INGROWTH STABILIZED IMPLANTS
    YOUNG, FA
    KELLER, JC
    KRESCH, CH
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 194 - 194
  • [39] Treatment of Severe Acetabular Bone Loss Using a Tantalum Acetabular Shell and a Cemented Monoblock Dual Mobility Acetabular Cup
    Melnic, Christopher M.
    Cohen-Levy, Wayne B.
    Lozano-Calderon, Santiago A.
    Heng, Marilyn
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (03) : E301 - E306
  • [40] A mechanobiological model for bone ingrowth on dental implants
    Perez, M. A.
    Garcia-Aznar, J. M.
    Doblare, M.
    Moreo, P.
    BIODENTAL ENGINEERING, 2010, : 89 - +