Analysis of bone ingrowth on a tantalum cup

被引:12
作者
D'Angelo, F. [1 ]
Murena, L. [1 ]
Campagnolo, M. [1 ]
Zatti, G. [1 ]
Cherubino, P. [1 ]
机构
[1] Univ Insubria, Dept Orthoaed & Traumatol, I-21100 Varese, Italy
关键词
Bone ingrowth; fixation; tantalum;
D O I
10.4103/0019-5413.39553
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Trabecular Metal (TM) is a new highly porous material made of tantalum (Zimmer, Warsaw, Indiana, USA). Its three-dimensional structure is composed of a series of interconnected dodecahedron pores that are on average 550 m in diameter. This size is considered optimal for bone ingrowth and is similar to trabecular bone. The elastic modulus of TM (3 GPa) is more similar to that of cancellous (0,1-1,5 GPa) or cortical (112-18 GPa) bone and is significantly less similar to that of Titanium (110 GPa) and Co-Cr alloys (220 GPa). These features enable bone apposition and remodeling. The purpose of the present study was to evaluate the histology of the bone-implant interface in a human specimen. Materials and Methods: A highly porous tantalum cup (Zimmer, Warsaw, Indiana, USA) was removed for recurrent dislocations three years after implantation. In order to obtain a slice of the cup, two cuts were made on the centre using an Exakt cutting machine. Then the slice was embedded in a Technovit resin and a Hematoxylin-eosin stain was used to study the bone tissue. Bone ingrowth was calculated using a method based on simple calculations of planar geometry. Results: The histological evaluation of the periprosthetic tissues revealed a typical chronic inflammation with few particles of polyethylene that were birefringent using polarized light. The quantitative evaluation of bone ingrowth revealed that more than 95 of voids were filled with bone. Discussion: In the literature, a lot of studies focused on tantalum were carried on animal model. Up to now little information is available about the histology of the bone-tantalum interface in a human artificial joint. We had an opportunity to remove a well integrated cup hence this study. The histology confirmed the strong relationship between the structure of this material and bone. The morphometric analysis revealed a high percentage of bone ingrowth.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 9 条
  • [1] Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
    Bobyn, JD
    Stackpool, GJ
    Hacking, SA
    Tanzer, M
    Krygier, JJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 907 - 914
  • [2] Tissue response to porous tantalum acetabular cups - A canine model
    Bobyn, JD
    Toh, KK
    Hacking, SA
    Tanzer, M
    Krygier, JJ
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (03) : 347 - 354
  • [3] HISTOLOGICAL AND RADIOGRAPHIC ASSESSMENT OF WELL-FUNCTIONING POROUS-COATED ACETABULAR COMPONENTS - A HUMAN POSTMORTEM RETRIEVAL STUDY
    ENGH, CA
    ZETTLSCHAFFER, KF
    KUKITA, Y
    SWEET, D
    VIRGINIA, A
    JASTY, M
    BRAGDON, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) : 814 - 824
  • [4] Radiographic evaluation of a monoblock acetabular component - A multicenter study with 2-to 5-year results
    Gruen, TA
    Poggie, RA
    Lewallen, DG
    Hanssen, AD
    Lewis, RJ
    O'Keefe, TJ
    Stulberg, SD
    Sutherland, CJ
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (03) : 369 - 378
  • [5] Komarasamy Baskaran, 2006, Acta Orthop Belg, V72, P320
  • [6] Radiological evaluation of the metal-bone interface of a porous tantalum monoblock acetabular component
    Macheras, GA
    Papagelopoulos, PJ
    Kateros, K
    Kostakos, AT
    Baltas, D
    Karachalios, TS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (03): : 304 - 309
  • [7] Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement
    Meneghini, R. Michael
    Lewallen, David G.
    Hanssen, Arlen D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) : 78 - 84
  • [8] PIDHORZ LE, 1993, J ARTHROPLASTY, V8, P213, DOI 10.1016/S0883-5403(09)80015-6
  • [9] The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects
    Sporer, Scott M.
    Paprosky, Wayne G.
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (06) : 83 - 86