Feasibility of Telementoring for Microneurosurgical Procedures Using a Microscope: A Proof-of-Concept Study

被引:5
|
作者
Ladd, Bryan M. [1 ]
Tackla, Ryan D. [2 ]
Gupte, Akshay [1 ]
Darrow, David [1 ]
Sorenson, Jeffery [4 ]
Zuccarello, Mario [2 ,3 ]
Grande, Andrew W. [1 ]
机构
[1] Univ Minnesota, Dept Neurosurg, Minneapolis, MN 55455 USA
[2] Univ Cincinnati, Coll Med, Dept Neurosurg, Cincinnati, OH 45267 USA
[3] Mayfield Clin, Cincinnati, OH USA
[4] Semmes Murphey Neurol & Spine Inst, Dept Neurosurg, Memphis, TN USA
关键词
Neurosurgery; Telementoring; Telescripting; ADRENALECTOMY; CHALLENGES; SURGERY; NEEDS;
D O I
10.1016/j.wneu.2016.11.121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Our pilot study evaluated the effectiveness of our telementoring-telescripting model to facilitate seamless communication between surgeons while the operating surgeon is using a microscope. METHODS: As a first proof of concept, 4 students identified 20 anatomic landmarks on a dry human skull with or without telementoring guidance. To assess the ability to communicate operative information, a senior neurosurgery resident evaluated the student's ability and timing to complete a stepwise craniotomy on a cadaveric head, with and without telementoring guidance; a second portion included exposure of the anterior circulation. The mentor was able to annotate directly onto the operator's visual field, which was visible to the operator without looking away from the binocular view. RESULTS: The students showed that they were familiar with half (50% +/- 10%) of the structures for identification and none was familiar with the steps to complete a craniotomy before using our system. With the guidance of a remote surgeon projected into the visual field of the microscope, the students were able to correctly identify 100% of the structures and complete a craniotomy. Our system also proved effective in guiding a more experienced neurosurgery resident through complex operative steps associated with exposure of the anterior circulation. CONCLUSIONS: Our pilot study showed a platform feasible in providing effective operative direction to inexperienced operators while operating using a microscope. A remote mentor was able to view the visual field of the microscope, annotate on the visual stream, and have the annotated stream appear in the binocular view for the operating mentee.
引用
收藏
页码:680 / 686
页数:7
相关论文
共 50 条
  • [1] Augmented-reality telementoring for leg fasciotomy: a proof-of-concept study
    McPherson, John
    Kennedy, C.
    Slobogean, G.
    Hilsden, R.
    Talbot, M.
    BMJ MILITARY HEALTH, 2023, 169 (04) : 355 - 358
  • [2] Magnetic Guidance of Cochlear Implants: Proof-of-Concept and Initial Feasibility Study
    Clark, James R.
    Leon, Lisandro
    Warren, Frank M.
    Abbott, Jake J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2012, 6 (03):
  • [3] Telementoring Feasibility Using a Novel Low-cost Lazy Glass Microsurgical Simulator: A "Proof of Concept" Experimental Study
    Bedi, Manbachan Singh
    Raheja, Amol
    Mishra, Shashwat
    Katiyar, Varidh
    Sharma, Ravi
    Narwal, Priya
    Garg, Kanwaljeet
    Tandon, Vivek
    Suri, Ashish
    Kale, Shashank Sharad
    WORLD NEUROSURGERY, 2022, 161 : 136 - 146
  • [4] Feasibility of using the Leap Motion Controller to administer conventional motor tests: a proof-of-concept study
    Kincaid, Clay
    Johnson, Paula
    Charles, Steven K.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [5] Craniotomy size determines the neurosurgeon-microscope interaction: A proof-of-concept study
    Pitskhelauri, D. I.
    Grachev, N. S.
    Danilov, G. V.
    Bykanov, A. E.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2023, 112 : 48 - 54
  • [6] Hypotension Prediction Index: from proof-of-concept to proof-of-feasibility
    de Keijzer, Ilonka N.
    Vos, Jaap Jan
    Scheeren, Thomas W. L.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (06) : 1135 - 1138
  • [7] Hypotension Prediction Index: from proof-of-concept to proof-of-feasibility
    Ilonka N. de Keijzer
    Jaap Jan Vos
    Thomas W. L. Scheeren
    Journal of Clinical Monitoring and Computing, 2020, 34 : 1135 - 1138
  • [8] The aiming device for cervical distractor pin insertion: a proof-of-concept, feasibility study
    Bunmaprasert, Torphong
    Luangkittikong, Sittichai
    Tosinthiti, Menghong
    Nivescharoenpisan, Supachoke
    Raphitphan, Raphi
    Sugandhavesa, Nantawit
    Liawrungrueang, Wongthawat
    Riew, K. Daniel
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [9] Gauging the feasibility of a downhole energy harvesting system through a proof-of-concept study
    Kjolsing, Eric
    Todd, Michael
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2016, 2016, 9799
  • [10] The aiming device for cervical distractor pin insertion: a proof-of-concept, feasibility study
    Torphong Bunmaprasert
    Sittichai Luangkittikong
    Menghong Tosinthiti
    Supachoke Nivescharoenpisan
    Raphi Raphitphan
    Nantawit Sugandhavesa
    Wongthawat Liawrungrueang
    K. Daniel Riew
    BMC Musculoskeletal Disorders, 22