Research on Lightning Over-voltage Protection for 500kV GIS Substation

被引:0
|
作者
Wang, Zhuo
Li, Lei
Gan, Ling Xia
Li, Ning
Li, Hong Tao
机构
来源
2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7 | 2009年
关键词
GIS substation; impulse corona; grounding resistance; position of lightning; over-voltage; TRANSIENTS; CORONA;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper combines incoming lines with 500kv GIS substation, considering the influence of the impulse voltage-second characteristics of insulator strings, the impulse corona of incoming lines, the impulse grounding resistance of tower and the position of lightning. ATP-EMTP simulation program is applied to analyze the lightning over-voltage of 500kv GIS substation. The result shows that impulse corona and the resistance of tower which is close to the substation have great influence on over-voltage, when lightning strike the tower which is close to terminal door-typed structure, the lightning over-voltage may be not the most serious, and when the over-voltage of the equipment is very serious, a group of arrester is installed which can decrease the over-voltage effectively. This research thinking takes safety and economy into account, which can provide new reference for the engineering.
引用
收藏
页码:3501 / 3505
页数:5
相关论文
共 50 条
  • [1] Research on Lightning Over-voltage and Lightning Protection of 500kV HGIS Substation
    Wang, Tong
    Fan, Youping
    PROCEEDINGS OF THE 2015 6TH INTERNATIONAL CONFERENCE ON MANUFACTURING SCIENCE AND ENGINEERING, 2016, 32 : 311 - 315
  • [2] Study on the lightning intruding over-voltage in 750 kV GIS substation
    Zhejiang Electric Power Test and Research Institute, Hangzhou 310014, China
    不详
    不详
    Gaodianya Jishu, 2006, 8 (18-21):
  • [3] Study on a Protection Scheme for a 500kV GIS Substation Against Direct Lightning Strokes
    Zhang, Liuchun
    Ge, Dong
    Zhang, Cuixia
    Yin, Yu
    Du, Shuchun
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1494 - 1497
  • [4] Research on Lightning Over-Voltage in 1000kV Gas Insulated Switchgear Substation
    Zhang, Yu
    Xu, Wei
    Liu, Nian
    Zhang, Yunhong
    Hu, Jiefeng
    Zhu, Jianguo
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 6212 - 6217
  • [5] Influence of Switching Conditions on Very Fast Transient Over-voltage in 500kV Gas Insulated Substation
    Liu, Qing
    Zhang, Yufeng
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4451 - 4454
  • [6] Over-voltage and lightning protection for 500 kV compact transmission line in high altitude area
    Zhao, Jian-Ning
    Gu, Ding-Xie
    Huo, Feng
    Cao, Jing
    Dai, Min
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (01): : 57 - 61
  • [7] Analysis on lightning overvoltage of 500kV substation
    Shao Yu
    Shao Ming
    Shi Feng
    Wang Kun
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1541 - 1545
  • [8] Research of Influencing Factors in the Simulation on 500kV GIS Substation
    Zhang Zongxi
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [9] Research of Lightning Over-voltage and Simulation Program of Substation Based on EMTP
    Chen Wei
    Zhou Shao-ping
    Chen He
    Luo Xiao-long
    Fan You-ping
    MACHINERY ELECTRONICS AND CONTROL ENGINEERING III, 2014, 441 : 318 - +
  • [10] Selection of Protection Scheme Against Lightning Impulse Waves Based on Chaos Theory for 500kV GIS Substation
    Li Yi
    Zhou Lixing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 1130 - 1134