Focus defect and dispersion mismatch in full-field optical coherence microscopy

被引:26
作者
Dubois, Arnaud [1 ]
机构
[1] Univ Paris Saclay, Grad Sch, Inst Opt, Lab Charles Fabry,CNRS, 2 Av Augustin Fresnel, F-91127 Palaiseau, France
关键词
ULTRAHIGH-RESOLUTION; REFRACTIVE-INDEX; THERMAL-LIGHT; INTERFERENCE MICROSCOPY; TEMPORAL COHERENCE; IN-VIVO; TOMOGRAPHY; TISSUE; INTERFEROMETRY; FLUORESCENCE;
D O I
10.1364/AO.56.00D142
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Full-field optical coherence microscopy (FFOCM) is an optical technique, based on low-coherence interference microscopy, for tomographic imaging of semi-transparent samples with micrometer-scale spatial resolution. The differences in refractive index between the sample and the immersion medium of the microscope objectives may degrade the FFOCM image quality because of focus defect and optical dispersion mismatch. These phenomena and their consequences are discussed in this theoretical paper. Experimental methods that have been implemented in FFOCM to minimize the adverse effects of these phenomena are summarized and compared. (C) 2017 Optical Society of America.
引用
收藏
页码:D142 / D150
页数:9
相关论文
共 51 条
[1]   Competence between spatial and temporal coherence in full field optical coherence tomography and interference microscopy [J].
Abdulhalim, I. .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2006, 8 (11) :952-958
[2]  
Abdulhalim I., 2009, J MOD OPTIC, V48, P279
[3]   Spatial and temporal coherence effects in interference microscopy and full-field optical coherence tomography [J].
Abdulhalim, Ibrahim .
ANNALEN DER PHYSIK, 2012, 524 (12) :787-804
[4]  
ALTMAN PL, 1972, BIOL DATA BOOK, V1
[5]  
Assayag O, 2014, TECHNOL CANCER RES T, V13, P455, DOI [10.7785/tcrtexpress.2013.600254, 10.7785/tcrt.2013.600254]
[6]   Imaging of non-tumorous and tumorous human brain tissues with full-field optical coherence tomography [J].
Assayag, Osnath ;
Grieve, Kate ;
Devaux, Bertrand ;
Harms, Fabrice ;
Pallud, Johan ;
Chretien, Fabrice ;
Boccara, Claude ;
Varlet, Pascale .
NEUROIMAGE-CLINICAL, 2013, 2 :549-557
[7]   Dark-field full-field optical coherence tomography [J].
Auksorius, Egidijus ;
Boccara, A. Claude .
OPTICS LETTERS, 2015, 40 (14) :3272-3275
[8]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[9]   Early chloroplastic alterations analysed by optical coherence tomography during a harpin-induced hypersensitive response [J].
Boccara, Martine ;
Schwartz, Wilfrid ;
Guiot, Elvire ;
Vidal, Guillaume ;
De Paepe, Rosine ;
Dubois, Arnaud ;
Boccara, Albert-Claude .
PLANT JOURNAL, 2007, 50 (02) :338-346
[10]  
Born M., 2002, Principles of Optics