DEVELOPMENT AND EVALUATION OF A HEAD-CONTROLLED HUMAN-COMPUTER INTERFACE WITH MOUSE-LIKE FUNCTIONS FOR PHYSICALLY DISABLED USERS

被引:17
作者
Martins Pereira, Cesar Augusto [1 ]
Bolliger Neto, Raul [1 ]
Reynaldo, Ana Carolina [2 ]
de Miranda Luzo, Maria Candida [2 ]
Oliveira, Reginaldo Perilo [1 ]
机构
[1] Univ Sao Paulo, Fac Med, Musculoskeletal Syst Med Res Lab LIM 41, Hosp Clin,Orthopaed & Traumatol Inst, Sao Paulo, Brazil
[2] Univ Sao Paulo, Fac Med, Occupat Therapy Div, Orthopaed & Traumatol Inst,Hosp Clin, Sao Paulo, Brazil
关键词
Quadriplegia; Computer peripherals; Computer systems; Computer-assisted image processing; Task performance and analysis; PERFORMANCE; TRACKING; ACCESS;
D O I
10.1590/S1807-59322009001000007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The objectives of this study were to develop a pointing device controlled by head movement that had the same functions as a conventional mouse and to evaluate the performance of the proposed device when operated by quadriplegic users. METHODS: Ten individuals with cervical spinal cord injury participated in functional evaluations of the developed pointing device. The device consisted of a video camera, computer software, and a target attached to the front part of a cap, which was placed on the user's head. The software captured images of the target coming from the video camera and processed them with the aim of determining the displacement from the center of the target and correlating this with the movement of the computer cursor. Evaluation of the interaction between each user and the proposed device was carried out using 24 multidirectional tests with two degrees of difficulty. RESULTS: According to the parameters of mean throughput and movement time, no statistically significant differences were observed between the repetitions of the tests for either of the studied levels of difficulty. CONCLUSIONS: The developed pointing device adequately emulates the movement functions of the computer cursor. It is easy to use and can be learned quickly when operated by quadriplegic individuals.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 28 条
  • [1] [Anonymous], P SIGCHI C HUM FACT
  • [2] Efficacy of three head-pointing devices for a mouse emulation task
    Anson, D
    Lawler, G
    Kissinger, A
    Timko, M
    Tuminski, J
    Drew, B
    [J]. ASSISTIVE TECHNOLOGY, 2002, 14 (02) : 140 - 150
  • [3] The camera mouse: Visual tracking of body features to provide computer access for people with severe disabilities
    Betke, M
    Gips, J
    Fleming, P
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2002, 10 (01) : 1 - 10
  • [4] BRYANT DP, 2003, ASSIST TECHNOL, P111
  • [5] DIAS N, 2003, 2 SEM ATIID AC
  • [6] Eom GM, 2007, INT J CONTROL AUTOM, V5, P147
  • [7] Controlling mouse pointer position using an infrared head-operated joystick
    Evans, DG
    Drew, R
    Blenkhorn, P
    [J]. IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (01): : 107 - 117
  • [8] THE INFORMATION CAPACITY OF THE HUMAN MOTOR SYSTEM IN CONTROLLING THE AMPLITUDE OF MOVEMENT
    FITTS, PM
    [J]. JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1954, 47 (06): : 381 - 391
  • [9] Graveleau V., 2005, P 8 INT C HUM COMP H, P306
  • [10] GREVE JMD, 2001, AVALIACAO INCAPACIDA, P87