Bone remodelling around HA-coated acetabular cups - A DEXA study with a 3-year follow-up in a randomised trial

被引:48
作者
Laursen, M. B.
Nielsen, P. T.
Soballe, K.
机构
[1] Aarhus Univ Hosp, No Ortopaed Div, Dept Hip & Knee Arthroplasty, DK-9000 Aalborg, Denmark
[2] Aarhus Univ Hosp, Dept Orthopaed, DK-9000 Aalborg, Denmark
关键词
TOTAL HIP-ARTHROPLASTY; PRESS-FIT; MINERAL DENSITY; COMPONENTS; FIXATION; IMPLANTS; MIGRATION; STEMS; DXA;
D O I
10.1007/s00264-006-0148-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to investigate bone remodelling around the cup in cementless THA. Previous studies indicate an advantage of better sealing of the bone-prosthesis interface by HA/TCP coating of implants, inhibiting polyethylene-induced osteolysis. One hundred patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy versus Trilogy Calcicoat (HA/TCP coated). The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric), with a modular 28-mm CrCo head. The Harris Hip Score (HHS) and bone mineral density (BMD) determined by DEXA scanning were used to study the effect. Measurements revealed no difference between the two groups after 3 years either in the clinical outcome or in terms of periprosthetic bone density. Patients with a body mass index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodelling.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 22 条
[1]   Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA [J].
Aldinger, PR ;
Sabo, D ;
Pritsch, M ;
Thomsen, M ;
Mau, H ;
Ewerbeck, V ;
Breusch, SJ .
CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (02) :115-121
[2]  
BAUER TW, 1993, J ARTHROPLASTY, V8, P167, DOI 10.1016/S0883-5403(09)80010-7
[3]   No adverse effects of early weight bearing after uncemented total hip arthroplasty -: A randomized study of 20 patients [J].
Bodén, H ;
Adolphson, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01) :21-29
[4]  
Engh CA, 1999, J ARTHROPLASTY, V14, P637
[5]  
GEHRCHEN PM, 1999, THESIS U COPENHAGEN
[6]   The Norwegian Arthroplasty Register -: 11 years and 73,000 arthroplasties [J].
Havelin, LI ;
Engesæter, LB ;
Espehaug, B ;
Furnes, O ;
Lie, SA ;
Vollset, SE .
ACTA ORTHOPAEDICA SCANDINAVICA, 2000, 71 (04) :337-353
[7]   No influence of body mass index on early outcome following total hip arthroplasty [J].
Ibrahim, T ;
Hobson, S ;
Beiri, A ;
Esler, CN .
INTERNATIONAL ORTHOPAEDICS, 2005, 29 (06) :359-361
[8]   MICROMOTION OF FEMORAL STEMS IN TOTAL HIP-ARTHROPLASTY - A RANDOMIZED STUDY OF CEMENTED, HYDROXYAPATITE-COATED, AND POROUS-COATED STEMS WITH ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS [J].
KARRHOLM, J ;
MALCHAU, H ;
SNORRASON, F ;
HERBERTS, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (11) :1692-1705
[9]   DXA scanning of acetabulum in patients with cementless total hip arthroplasty [J].
Laursen, MB ;
Nielsen, PT ;
Soballe, K .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) :476-483
[10]   Detection of bony defects around cementless acetabular components in total hip arthroplasty - A DEXA study on 10 human cadavers [J].
Laursen, Mogens B. ;
Nielsen, Poul T. ;
Soballe, Kjeld .
ACTA ORTHOPAEDICA, 2006, 77 (02) :209-217