Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film

被引:9
作者
Devic, Slobodan [1 ,2 ]
Liang, LiHeng [1 ,2 ]
Tomic, Nada [1 ,2 ]
Bekerat, Hamed [1 ,2 ]
Morcos, Marc [1 ,2 ,3 ]
Popovic, Marija [1 ,4 ]
Watson, Peter [1 ,4 ]
Aldelaijan, Saad [1 ,5 ,6 ]
Seuntjens, Jan [1 ,4 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[4] Montreal Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[5] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ, Canada
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 64卷
基金
加拿大自然科学与工程研究理事会;
关键词
Electronic brachytherapy; Radiochromic film dosimetry; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigate the effect of the GafChromic (TM) film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Measurement strips of EBT3 film were positioned at distances of 2-6 cm from the Xoft source in a water phantom using a custom-made holder and irradiated simultaneously. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 5%. However, if the calibration curve was established in an MV beam quality, the error in absorbed dose could be as large as 20%. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at appropriate corresponding low energies, as large absorbed dose errors are expected when film calibration is performed in MV beam qualities.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [41] Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons
    Ballester, Facundo
    Granero, Domingo
    Perez-Calatayud, Jose
    Melhus, Christopher S.
    Rivard, Mark J.
    MEDICAL PHYSICS, 2009, 36 (09) : 4250 - 4256
  • [42] On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-based study
    Valdes-Cortez, Christian
    Niatsetski, Yury
    Ballester, Facundo
    Vijande, Javier
    Candela-Juan, Cristian
    Perez-Calatayud, Jose
    MEDICAL PHYSICS, 2020, 47 (02) : 693 - 702
  • [43] An investigation into the INTRABEAM miniature x-ray source dosimetry using ionization chamber and radiochromic film measurements
    Watson, Peter G. F.
    Bekerat, Hamed
    Papaconstadopoulos, Pavlos
    Davis, Stephen
    Seuntjens, Jan
    MEDICAL PHYSICS, 2018, 45 (09) : 4274 - 4286
  • [44] Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources
    Antonovic, Laura
    Gustafsson, Hakan
    Carlsson, Gudrun Alm
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2009, 36 (06) : 2236 - 2247
  • [45] A comparison of dose distributions of HDR intracavitary brachytherapy using different sources and treatment planning systems
    Park, Dong-Wook
    Kim, Young Seok
    Park, Sung Ho
    Choi, Eun Kyung
    Do Ahn, Seung
    Lee, Sang-Wook
    Song, Si Yeol
    Kim, Jong Hoon
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1426 - 1431
  • [46] Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGER® radiochromic plastic
    Palmer, A. L.
    Di Pietro, P.
    Alobaidli, S.
    Issa, F.
    Doran, S.
    Bradley, D.
    Nisbet, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [47] Anode optimization for miniature electronic brachytherapy X-ray sources using Monte Carlo and computational fluid dynamic codes
    Khajeh, Masoud
    Safigholi, Habib
    JOURNAL OF ADVANCED RESEARCH, 2016, 7 (02) : 225 - 232
  • [48] Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation
    Cote, Nicolas
    Bedwani, Stephane
    Carrier, Jean-Franois
    MEDICAL PHYSICS, 2016, 43 (05) : 2611 - 2618
  • [49] Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films
    Kawashima, Motohiro
    Matsumura, Akihiko
    Souda, Hikaru
    Tashiro, Mutsumi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12)
  • [50] Changes in dose with segmentation of breast tissues in Monte Carlo calculations for low-energy brachytherapy
    Sutherland, J. G. H.
    Thomson, R. M.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2011, 38 (08) : 4858 - 4865