Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film

被引:9
作者
Devic, Slobodan [1 ,2 ]
Liang, LiHeng [1 ,2 ]
Tomic, Nada [1 ,2 ]
Bekerat, Hamed [1 ,2 ]
Morcos, Marc [1 ,2 ,3 ]
Popovic, Marija [1 ,4 ]
Watson, Peter [1 ,4 ]
Aldelaijan, Saad [1 ,5 ,6 ]
Seuntjens, Jan [1 ,4 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[4] Montreal Gen Hosp, Dept Radiat Oncol, Montreal, PQ, Canada
[5] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ, Canada
[6] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 64卷
基金
加拿大自然科学与工程研究理事会;
关键词
Electronic brachytherapy; Radiochromic film dosimetry; DOSIMETRY;
D O I
10.1016/j.ejmp.2019.05.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigate the effect of the GafChromic (TM) film EBT3 model absorbed dose energy response when used for dose measurements around low-energy photon sources. Monte Carlo based correction procedure in synergy with appropriate calibration curves was shown to provide more accurate absorbed dose (either relative or absolute). An assessment was made of possible dose errors that might be encountered if such energy dependent response is ignored. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Measurement strips of EBT3 film were positioned at distances of 2-6 cm from the Xoft source in a water phantom using a custom-made holder and irradiated simultaneously. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 5%. However, if the calibration curve was established in an MV beam quality, the error in absorbed dose could be as large as 20%. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at appropriate corresponding low energies, as large absorbed dose errors are expected when film calibration is performed in MV beam qualities.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 50 条
  • [21] Measurement of gold nanofilm dose enhancement using unlaminated radiochromic film
    Rakowski, Joseph T.
    Laha, Suvra S.
    Snyder, Michael G.
    Buczek, Matthew G.
    Tucker, Mark A.
    Liu, Fangchao
    Mao, Guangzhao
    Hillman, Yair
    Lawes, Gavin
    MEDICAL PHYSICS, 2015, 42 (10) : 5937 - 5944
  • [22] A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources
    Mashouf, Shahram
    Lechtman, Eli
    Beaulieu, Luc
    Verhaegen, Frank
    Keller, Brian M.
    Ravi, Ananth
    Pignol, Jean-Philippe
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18) : 6299 - 6315
  • [23] Dose comparison between TG-43-based calculatiOns and radiochromic film measurements of the Freiburg flap applicator used for high-dose-rate brachytherapy treatments of skin lesions
    Aldelaijan, Saad
    Bekerat, Hamed
    Buzurovic, Ivan
    Devlin, Phillip
    DeBlois, Francois
    Seuntjens, Jan
    Devic, Slobodan
    BRACHYTHERAPY, 2017, 16 (05) : 1065 - 1072
  • [24] Dosimetry of a sonolucent material for an ultrasound -compatible gynecologic high-dose-rate brachytherapy cylinder using Monte Carlo simulation and radiochromic film
    Van Elburg, Devin J.
    Roumeliotis, Michael
    Morrison, Hali
    Rodgers, Jessica R.
    Fenster, Aaron
    Meyer, Tyler
    BRACHYTHERAPY, 2021, 20 (01) : 265 - 271
  • [25] Dose profile evaluation in digital breast tomosynthesis exposition using radiochromic film
    Flores, Mabel B.
    Mourao, Arnaldo P.
    Oliveira, Fernando A.
    del Rio, Margarita C.
    APPLIED RADIATION AND ISOTOPES, 2019, 152 : 140 - 144
  • [26] Radiochromic EBT2 film dosimetry for low-energy protontherapy
    Angellier, G.
    Gautier, M.
    Herault, J.
    MEDICAL PHYSICS, 2011, 38 (11) : 6171 - 6177
  • [27] PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY
    MUENCH, PJ
    MEIGOONI, AS
    NATH, R
    MCLAUGHLIN, WL
    MEDICAL PHYSICS, 1991, 18 (04) : 769 - 775
  • [28] Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source
    White, Shane A.
    Landry, Guillaume
    Fonseca, Gabriel Paiva
    Holt, Randy
    Rusch, Thomas
    Beaulieu, Luc
    Verhaegen, Frank
    Reniers, Brigitte
    MEDICAL PHYSICS, 2014, 41 (06)
  • [29] Dosimetry formalism and calibration procedure for electronic brachytherapy sources in terms of absorbed dose to water
    Abudra'a, A.
    Chauvenet, B.
    Gouriou, J.
    Plagnard, J.
    Itti, R.
    Aubineau-Laniece, I
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14)
  • [30] Measurement of absorbed dose to water around an electronic brachytherapy source. Comparison of two dosimetry systems: lithium formate EPR dosimeters and radiochromic EBT2 film
    Adolfsson, Emelie
    White, Shane
    Landry, Guillaume
    Lund, Eva
    Gustafsson, Hakan
    Verhaegen, Frank
    Reniers, Brigitte
    Tedgren, Asa Carlsson
    Carlsson, Gudrun Alm
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3869 - 3882