Response of gafchromic md-55 radiochromic film to synchrotron radiation

被引:0
作者
Nariyama, N [1 ]
Namito, Y [1 ]
Ban, S [1 ]
Hirayama, H [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
来源
SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS | 2002年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Synchrotron radiation has been increasingly and extensively used for materials science, biology and medical research. For measurement of high dose from the low energy photons, tissue-equivalent dosemeters having linearity in the Gy region are required. In this study, energy and dose responses of double-layer Gafchromic film MD-55 were measured using 10-40 keV monoenergetic photons from synchrotron radiation. The result showed that the energy response, normalised at Co-60 gamma rays were 0.58-0.59 at 10-20 keV, 0.66 at 30 keV and 0.72 at 40 keV in air. The linearity was confirmed to extend from 2 Gy to 100 Gy.
引用
收藏
页码:349 / 352
页数:4
相关论文
共 10 条
[1]  
[Anonymous], 1998, 63 AAPM
[2]  
Attix F H, 1986, INTRO RADIOLOGICAL P
[3]   HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED [J].
CHIUTSAO, ST ;
DELAZERDA, A ;
LIN, J ;
KIM, JH .
MEDICAL PHYSICS, 1994, 21 (05) :651-657
[4]   Dose response of various radiation detectors to synchrotron radiation [J].
Kron, T ;
Duggan, L ;
Smith, T ;
Rosenfeld, A ;
Butson, M ;
Kaplan, G ;
Howlett, S ;
Hyodo, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) :3235-3259
[5]   Novel radiochromic films for clinical dosimetry [J].
McLaughlin, WL ;
Puhl, JM ;
AlSheikhly, M ;
Christou, CA ;
Miller, A ;
Kovacs, A ;
Wojnarovits, L ;
Lewis, DF .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :263-268
[6]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[7]   RESPONSES OF LIF TLDS TO 10-40 KEV MONOENERGETIC PHOTONS FROM SYNCHROTRON-RADIATION [J].
NARIYAMA, N ;
TANAKA, S ;
YOSHIZAWA, M ;
HIRAYAMA, H ;
BAN, S ;
NAKASHIMA, H ;
NAMITO, Y ;
NAKANE, Y .
RADIATION PROTECTION DOSIMETRY, 1993, 49 (04) :451-457
[8]   Comparison of in-phantom dose distributions for coronary angiography using an x-ray machine and synchrotron radiation [J].
Nariyama, N ;
Tanaka, S ;
Nakane, Y ;
Nakashima, H ;
Hirayama, H ;
Ban, S ;
Namito, Y ;
Hyodo, K ;
Takeda, T .
MEDICAL PHYSICS, 2001, 28 (01) :16-21
[9]  
Nelson W., 1985, SLAC265
[10]   Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetry [J].
Reinstein, LE ;
Gluckman, GR ;
Amols, HI .
MEDICAL PHYSICS, 1997, 24 (12) :1935-1942