BODIPY-Hg2+ Complex: A Fluorescence "Turn-ON" Sensor for Cysteine Detection

被引:3
|
作者
Kumar, Monu [1 ]
Chaudhary, Garima [1 ]
Singh, Amit Pratap [1 ]
机构
[1] Natl Inst Technol Delhi, Dept Appl Sci, New Delhi 110040, India
关键词
BODIPY; Hg2+ ions detection; cysteine; Job's plot; SELECTIVE DETECTION; LIVE CELLS; PROBE; HG2+; COPPER; DYES; CHEMOSENSORS; TOXICITY; DESIGN; THIOLS;
D O I
10.2116/analsci.20P255
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A BODIPY (4,4-difluoro-4-bora-3a,4a-diaza-s-indacene) based pioneering sensing material (HLPy) having 2-amino pyridine as receptor was synthesized and used for the selective detection of Hg2+ ions. The synthesized HLPy features a high affinity towards Hg2+ (k(a) = 2.04 x 10(5) M-1), accompanied by effective quenching of fluorescence in DMF:H2O (1:9 v/v, 10 mM HEPES buffer, pH 7.4) with 54 nM limit of detection (LOD). The emission titration experiments (Job's plot) in the presence of varying mole-fraction of Hg2+ ions reveals the formation of non-fluorescent 2:1 coordination complex [Hg(L-Py)(2)]. The resulting non-fluorescent [Hg(L-Py)(2)] was thoroughly characterized using various spectroscopic techniques and analyses. Interestingly, the non-fluorescent complex [Hg(L-Py)(2)] is able to specifically respond towards Cys over other biothiols and amino acids through a reversible de-complexation mechanism. As a result, the remarkable recovery of the fluorescence can be observed. The limit of detection (LOD) for Cys detection is estimated to be 29 nM in DMF:H2O (1:9 v/v, 10 mM HEPES buffer, pH 8.0). The reversibility and reusability of [Hg(L-Py)(2)] were achieved by the sequential addition of Cys and Hg2+ ions up to five cycles. Moreover, the removal of Hg2+ ions up to 89% from aqueous samples using HLPy was successfully demonstrated.
引用
收藏
页码:283 / 292
页数:10
相关论文
共 50 条
  • [41] A mononuclear zinc complex for selective detection of diphosphate via ESIPT fluorescence turn-on
    Wang, Junfeng
    Chen, Weihua
    Liu, Xiumin
    Wesdemiotis, Chrys
    Pang, Yi
    JOURNAL OF MATERIALS CHEMISTRY B, 2014, 2 (21) : 3349 - 3354
  • [42] BODIPY- imine based fluorescence "turn on" chemosensor for selective sensing of Hg2+
    Kirpik, Hilal
    Kose, Muhammet
    Elmes, Robert B. P.
    Karabork, Muharrem
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2024, 451
  • [43] Rhodamine-Immobilised Electrospun Chitosan Nanofibrous Material as a Fluorescence Turn-On Hg2+ Sensor
    Horzum, Nesrin
    Mete, Derya
    Karakus, Erman
    Ucuncu, Muhammed
    Emrullahoglu, Mustafa
    Demir, Mustafa M.
    CHEMISTRYSELECT, 2016, 1 (05): : 896 - 900
  • [44] Perylene diimide based 'turn-on' fluorescence sensor for detection of Pd2+ in mixed aqueous media
    Wang, Hai-xia
    Lang, Yue-he
    Wang, Hui-xuan
    Lou, Jing-jing
    Guo, Hai-ming
    Li, Xi-you
    TETRAHEDRON, 2014, 70 (11) : 1997 - 2002
  • [45] A Benzil- and BODIPY-Based Turn-On Fluorescent Probe for Detection of Hydrogen Peroxide
    Wang, Yunxia
    Liu, Ye
    Liu, Bo
    Yuan, Yihua
    Wei, Lixia
    Wang, Mingxiu
    Chen, Zhe
    MOLECULES, 2024, 29 (01):
  • [46] Cysteine-based fluorescence "turn-on" sensors for Cu2+ and Ag+
    Haridas, V.
    Kumar, P. P. Praveen
    Suresh, Cherumuttathu H.
    RSC ADVANCES, 2014, 4 (99) : 56539 - 56542
  • [47] Turn-on fluorescence sensor for the detection of heparin based on rhodamine B-modified polyethyleneimine-graphene oxide complex
    Liu, Jinshui
    Liu, Guoning
    Liu, Wenxiu
    Wang, Yiru
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 300 - 305
  • [48] Nucleophilic addition of CN- ion to -C=N bond of aza-BODIPY leading to turn-on fluorescence sensor
    Dvivedi, Avanish
    Kumar, Sunit
    Ravikanth, Mangalampalli
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 364 - 371
  • [49] Novel BODIPY-Based Fluorescence Turn-on Sensor for Fe3+ and Its Bioimaging Application in Living Cells
    Sui, Binglin
    Tang, Simon
    Liu, Taihong
    Kim, Bosung
    Belfield, Kevin D.
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (21) : 18408 - 18412
  • [50] A dioxadithiaazacrown ether-BODIPY dyad Hg2+ complex for detection of L-cysteine: fluorescence switching and application to soft material
    Kaur, Navdeep
    Kaur, Paramjit
    Singh, Kamaljit
    RSC ADVANCES, 2014, 4 (55) : 29340 - 29343