Ultrafine particle concentrations in a hospital

被引:19
作者
Riesenfeld, E
Chalupa, D
Gibb, FR
Oberdörster, G
Gelein, R
Morrow, PE
Utell, MJ
Frampton, MW
机构
[1] Univ Rochester, Sch Med, Dept Med, Rochester, NY 14642 USA
[2] Univ Rochester, Sch Med, Dept Environm Med, Rochester, NY 14642 USA
关键词
D O I
10.1080/08958378.2000.11463201
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Ultrafine particles (UFP) may contribute to the morbidity and mortality associated with exposure to ambient particles, but few data are available on ultrafine particle numbers in indoor air, where susceptible subjects spend most of their time. We measured particle number, UFP size distribution, and total suspended particulate (TSP) mass in three locations: (1) a medical floor in a large tertiary care hospital, (2) outdoor air above a construction site outside the hospital, and (3) an environmental exposure chamber with purification of intake air. Mass and number concentrations were recorded continuously in each location over 70-110 h. Mean +/- SD particle (p) numbers were 3.63 +/- 1.15 x 10(3) p/cm(3) in the hospital, 3.05 +/- 6.65 x 10(4) p/cm(3) outside, and 5.86 +/- 2.11 x 10(2) p/cm(3) in the environmental chamber. In the hospital, particle number and mass declined during the evening hours when the unit was less active, with the particle number as low as 1.15 x 10(3) p/cm(3). Particle numbers peaked (2.78 x 10(4) p/cm(3)) in the morning hours when activity on the unit was the most intense. "Spikes" in fine particle number were often not accompanied by increases in TSP mass. In the hospital, a distinct population of ultrafine particles (median diameter approximately 23 nm) was observed during the lunch hour, suggesting a change in particle source during this time. Outdoor fine particle numbers above the construction sire were highly variable, reaching peaks of greater than 1.7 x 10(6) p/cm(3). These data suggest that, in the indoor environment, particle numbers and size distribution vary with intensity and type of local activity, and significant peaks in particle number are not detected with daily averages. Monitoring of particle mass may be an inaccurate measure of exposure to ultrafine particles indoors.
引用
收藏
页码:83 / 94
页数:12
相关论文
共 20 条
[1]  
[Anonymous], 1996, REV NAT AMB AIR QUAL
[2]  
Bascom R, 1996, AM J RESP CRIT CARE, V153, P3, DOI 10.1164/ajrccm.153.1.8542133
[3]   CHARACTERIZATION OF ENVIRONMENTAL AEROSOLS ON HELIGOLAND ISLAND [J].
BRAND, P ;
GEBHART, J ;
BELOW, M ;
GEORGI, B ;
HEYDER, J .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1991, 25 (3-4) :581-585
[4]   PERFORMANCE OF A MOBILE AEROSOL SPECTROMETER FOR AN INSITU CHARACTERIZATION OF ENVIRONMENTAL AEROSOLS IN FRANKFURT CITY [J].
BRAND, P ;
RUOSS, K ;
GEBHART, J .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (13) :2451-2457
[5]   INDOOR OUTDOOR AIR-POLLUTION RELATIONS - PARTICULATE MATTER LESS THAN 10 MU IN AERODYNAMIC DIAMETER (PM-10) IN HOMES OF ASTHMATICS [J].
COLOME, SD ;
KADO, NY ;
JAQUES, P ;
KLEINMAN, M .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (12) :2173-2178
[6]   Invasive aspergillosis [J].
Denning, DW .
CLINICAL INFECTIOUS DISEASES, 1998, 26 (04) :781-803
[7]  
Janssen NAH, 1998, AM J EPIDEMIOL, V147, P537
[8]   THE PERSONAL, INDOOR AND OUTDOOR CONCENTRATIONS OF PM-10 MEASURED IN AN INDUSTRIAL COMMUNITY DURING THE WINTER [J].
LIOY, PJ ;
WALDMAN, JM ;
BUCKLEY, T ;
BUTLER, J ;
PIETARINEN, C .
ATMOSPHERIC ENVIRONMENT PART B-URBAN ATMOSPHERE, 1990, 24 (01) :57-66
[9]   Typical household vacuum cleaners: The collection efficiency and emissions characteristics for fine particles [J].
Lioy, PJ ;
Wainman, T ;
Zhang, JF ;
Goldsmith, S .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (02) :200-206
[10]   Particulate matter less than 10 μm (PM10) and fine particles less than 2.5 μm (PM2.5):: relationships between indoor, outdoor and personal concentrations [J].
Monn, C ;
Fuchs, A ;
Hogger, D ;
Junker, M ;
Kogelschatz, D ;
Roth, N ;
Wanner, HU .
SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 208 (1-2) :15-21