Candidemia in patients with ventricular assist devices

被引:24
作者
Shoham, Shmuel
Shaffer, Rebecca
Sweet, Leslie
Cooke, Richard
Donegan, Nancy
Boyce, Steven
机构
[1] Washington Hosp Ctr, Dept Infect Dis, Washington, DC 20010 USA
[2] Washington Hosp Ctr, Dept Cardiovasc Surg, Washington, DC 20010 USA
[3] Washington Hosp Ctr, Dept Cardiol, Washington, DC 20010 USA
[4] Washington Hosp Ctr, Dept Infect Control, Washington, DC 20010 USA
关键词
D O I
10.1086/509640
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
During the period 1998 - 2004, candidemia developed in 7 of 117 ventricular assist device recipients at our hospital, and the associated mortality rate was 71%. Five cases of candidemia were due to Candida parapsilosis, and 2 were due to Candida albicans. Three of the 7 patients with ventricular assist device - associated Candida bloodstream infections were cured, and the device was retained in 2 of the 3 patients.
引用
收藏
页码:E9 / E12
页数:4
相关论文
共 18 条
[1]   LYSIS CENTRIFUGATION BLOOD CULTURES IN THE DETECTION OF TISSUE-PROVEN INVASIVE CANDIDIASIS - DISSEMINATED VERSUS SINGLE-ORGAN INFECTION [J].
BERENGUER, J ;
BUCK, M ;
WITEBSKY, F ;
STOCK, F ;
PIZZO, PA ;
WALSH, TJ .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1993, 17 (02) :103-109
[2]   Epidemiologic and molecular characterization of an outbreak of Candida parapsilosis bloodstream infections in a community hospital [J].
Clark, TA ;
Slavinski, SA ;
Morgan, J ;
Lott, T ;
Arthington-Skaggs, BA ;
Brandt, ME ;
Webb, RM ;
Currier, M ;
Flowers, RH ;
Fridkin, SK ;
Hajjeh, RA .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (10) :4468-4472
[3]   An outbreak of Candida parapsilosis prosthetic valve endocarditis [J].
Diekema, DJ ;
Messer, SA ;
Hollis, RJ ;
Wenzel, RP ;
Pfaller, MA .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1997, 29 (03) :147-153
[4]   Infectious complications in left ventricular assist device recipients [J].
Fischer, SA ;
Trenholme, GM ;
Costanzo, MR ;
Piccione, W .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (01) :18-23
[5]   Fungal infections in ventricular assist devices [J].
Goldberg, SP ;
Baddley, JW ;
Aaron, MF ;
Pappas, PG ;
Holman, WL .
ASAIO JOURNAL, 2000, 46 (06) :S37-S40
[6]  
Goldstein D J, 1995, ASAIO J, V41, P873, DOI 10.1097/00002480-199510000-00010
[7]   Medical progress - Implantable left ventricular assist devices [J].
Goldstein, DJ ;
Oz, MC ;
Rose, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (21) :1522-1533
[8]   Nosocomial bloodstream infections in patients with implantable left ventricular assist devices [J].
Gordon, SM ;
Schmitt, SK ;
Jacobs, M ;
Smedira, NM ;
Goormastic, M ;
Banbury, MK ;
Yeager, M ;
Serkey, J ;
Hoercher, K ;
McCarthy, PM .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :725-730
[9]   Infectious complications in patients with the novacor left ventricular assist system [J].
Grossi, P ;
Dalla Gasperina, D ;
Pagani, F ;
Marone, P ;
Viganò, M ;
Minoli, L .
TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) :1969-1971
[10]  
Herrmann M, 1997, CIRCULATION, V95, P814