Square-Wave Voltammetry Determination of Ciprofloxacin in Pharmaceutical Formulations and Milk Using a Reduced Graphene Oxide Sensor

被引:48
作者
Faria, Lucas, V [1 ]
Pereira, Jian F. S. [2 ]
Azevedo, Gustavo C. [1 ]
Matos, Maria A. C. [1 ]
Munoz, Rodrigo A. A. [2 ]
Matos, Renato C. [1 ]
机构
[1] Univ Fed Juiz de Fora, Dept Quim, BR-36026900 Juiz De Fora, MG, Brazil
[2] Univ Fed Uberlandia, Inst Quim, BR-38400902 Uberlandia, MG, Brazil
关键词
chemically-reduced graphene-oxide; ciprofloxacin; pharmaceutical formulations; milk; square wave voltammetry; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL DETECTION; CAPILLARY-ELECTROPHORESIS; RAPID-DETERMINATION; NANOTUBES; URINE; ENROFLOXACIN; FABRICATION; REDUCTION;
D O I
10.21577/0103-5053.20190108
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, a simple. sensitive and precise electroanalytical method was developed using a chemically-reduced graphene-oxide (CRGO)-modified glassy carbon electrode and square wave voltammetry (SWV) for determination of ciprofloxacin in pharmaceutical formulations (tablets) and milk samples. Advantages of this sensor include a potential displacement of 100 mV and a 5-fold current increase for the electrochemical oxidation of ciprofloxacin, which resulted in a highly sensitive sensor, when compared to unmodified electrode. The improved properties of the modified electrode are likely due to the formation of a porous surface evidenced by the change in electrode kinetics (thin-layer diffusion process). The proposed sensor is free from interference of sample matrix (pharmaceutical formulations and low/high-fat milk) avoiding cumbersome processes such as previous separations, solvent extraction, or sample filtration (samples were only diluted in Britton-Robinson buffer solution). The results by SWV showed a limit of detection of 0.21 mu mol L-1 (correspondent to 0.069 mg L (-1)), which is lower than the ones obtained using other carbon-based electrodes, relative standard deviations lower than 12%, and satisfactory recoveries in the range from 84 to 109%. The results obtained were statistically similar (95% confidence level) with those performed through high-performance liquid chromatography (HPLC).
引用
收藏
页码:1947 / 1954
页数:8
相关论文
共 44 条
[1]   Electrochemical reduction of ciprofloxacin at the mercury electrode and its voltammetric determination in tablet and urine [J].
Al-Ghamdi, Ali F. ;
Bani-Yaseen, Abdulilah Dawoud .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (04) :355-362
[2]  
Aleixo H, 2019, ANAL METHODS-UK, V11, P1743, DOI [10.1039/c9ay00094a, 10.1039/C9AY00094A]
[3]   Electrochemically Exfoliated Graphene and Graphene Oxide for Energy Storage and Electrochemistry Applications [J].
Ambrosi, Adriano ;
Pumera, Martin .
CHEMISTRY-A EUROPEAN JOURNAL, 2016, 22 (01) :153-159
[4]   Evaluation of physicochemical properties as supporting information on quality control of raw materials and veterinary pharmaceutical formulations [J].
Anacleto, Sara da Silva ;
Cordeiro Borges, Marcella Matos ;
de Oliveira, Hanna Leijoto ;
Vicente, Andressa Reis ;
de Figueiredo, Eduardo Costa ;
Leal de Oliveira, Marcone Augusto ;
Pinheiro Borges, Barbara Juliana ;
de Oliveira, Marcelo Antonio ;
Borges, Warley de Souza ;
Borges, Keyller Bastos .
JOURNAL OF PHARMACEUTICAL ANALYSIS, 2018, 8 (03) :168-175
[5]   Capillary electrophoresis with laser-induced fluorescence detection, an adequate alternative to high-performance liquid chromatography, for the determination of ciprofloxacin and its metabolite desethyleneciprofloxacin in human plasma [J].
Bannefeld, KH ;
Stass, H ;
Blaschke, G .
JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (02) :453-459
[6]   Electrochemical oxidation of sulfamethazine on a glassy carbon electrode modified with graphene and gold nanoparticles [J].
Cesarino, Ivana ;
Simoes, Rafael Plana ;
Lavarda, Francisco Carlos ;
Batagin-Neto, Augusto .
ELECTROCHIMICA ACTA, 2016, 192 :8-14
[7]   A nano-carbon electrode optimized for adsorptive stripping voltammetry: Application to detection of the stimulant selegiline in authentic saliva [J].
dos Santos, Wallans T. P. ;
Amin, Hatem M. A. ;
Compton, Richard G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 279 :433-439
[8]   The chemistry of graphene oxide [J].
Dreyer, Daniel R. ;
Park, Sungjin ;
Bielawski, Christopher W. ;
Ruoff, Rodney S. .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) :228-240
[9]   Simultaneous Voltammetric Determination of Enrofloxacin and Ciprofloxacin in Urine and Plasma Using Multiwall Carbon Nanotubes Modified Glassy Carbon Electrode by Least-Squares Support Vector Machines [J].
Ensafi, Ali A. ;
Taei, M. ;
Khayamian, T. ;
Hasanpour, F. .
ANALYTICAL SCIENCES, 2010, 26 (07) :803-808
[10]   Electrochemical behavior and analytical application of ciprofloxacin using a multi-walled nanotube composite film-glassy carbon electrode [J].
Fotouhi, Lida ;
Alahyari, Mahnaz .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 81 (01) :110-114