Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres

被引:123
作者
Garin, Etienne [1 ,2 ,3 ]
Rolland, Yan [4 ]
Laffont, Sophie [2 ]
Edeline, Julien [2 ,3 ,5 ]
机构
[1] Canc Inst Eugene Marquis, Dept Nucl Med, CS 44229, F-35042 Rennes, France
[2] Univ Rennes 1, F-35043 Rennes, France
[3] INSERM, Liver Metab & Canc, U991, F-35033 Rennes, France
[4] Canc Inst Eugene Marquis, Dept Med Imaging, CS 44229, F-35042 Rennes, France
[5] Canc Inst Eugene Marquis, Dept Med Oncol, CS 44229, F-35042 Rennes, France
关键词
Selective internal radiation therapy; Predictive dosimetry; Prognosis; HEPATOCELLULAR-CARCINOMA PATIENTS; INTERNAL RADIATION-THERAPY; Y-90 RESIN MICROSPHERES; GLASS MICROSPHERES; PREDICTIVE DOSIMETRY; ALBUMIN SPECT/CT; PARTITION MODEL; BLOOD-FLOW; CANCER; METASTASES;
D O I
10.1007/s00259-015-3157-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radioembolization with Y-90-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. Conclusion: MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose.
引用
收藏
页码:559 / 575
页数:17
相关论文
共 57 条
[1]   Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings [J].
Bilbao, Jose I. ;
de Martino, Alba ;
de Luis, Esther ;
Diaz-Dorronsoro, Lourdes ;
Alonso-Burgos, Alberto ;
Martinez de la Cuesta, Antonio ;
Sangro, Bruno ;
Garcia de Jalon, Jose A. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) :727-736
[2]  
BURTON MA, 1985, CANCER RES, V45, P5390
[3]   EFFECT OF ANGIOTENSIN-II ON BLOOD-FLOW IN THE TRANSPLANTED SHEEP SQUAMOUS-CELL CARCINOMA [J].
BURTON, MA ;
GRAY, BN ;
COLETTI, A .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1988, 24 (08) :1373-1376
[4]  
Chiesa C, 2012, Q J NUCL MED MOL IM, V56, P503
[5]  
Chiesa C, 2011, Q J NUCL MED MOL IM, V55, P168
[6]   Radioembolisation with 90Y-microspheres: dosimetric and radiobiological investigation for multi-cycle treatment [J].
Cremonesi, Marta ;
Ferrari, Mahila ;
Bartolomei, Mirco ;
Orsi, Franco ;
Bonomo, Guido ;
Arico, Demetrio ;
Mallia, Andrew ;
De Cicco, Concetta ;
Pedroli, Guido ;
Paganelli, Giovanni .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) :2088-2096
[7]  
Dancey JE, 2000, J NUCL MED, V41, P1673
[8]  
De Gersem R, 2013, CLIN NUCL MED, V38, P940, DOI 10.1097/RLU.0000000000000241
[9]  
Dhabuwala Atul, 2005, BMC Nucl Med, V5, P7, DOI 10.1186/1471-2385-5-7
[10]   99mTc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with 166Ho-microspheres [J].
Elschot, Mattijs ;
Nijsen, Johannes F. W. ;
Lam, Marnix G. E. H. ;
Smits, Maarten L. J. ;
Prince, Jip F. ;
Viergever, Max A. ;
van den Bosch, Maurice A. A. J. ;
Zonnenberg, Bernard A. ;
de Jong, Hugo W. A. M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (10) :1965-1975