Soft tissue replication in single unit implant impressions-A three dimensional clinical study

被引:9
作者
da Silva Marques, Duarte Nuno [1 ,2 ,3 ]
Marques Pinto, Ricardo Jorge [2 ]
Aparicio Aguiar Alves, Rita Vanessa [2 ]
Baratieri, Luiz Narciso [4 ]
Sola Pereira da Mata, Antonio Duarte [2 ,3 ]
Mendez Carames, Joao Manuel [3 ,5 ,6 ]
机构
[1] Implantol Inst, Dept Oral Rehabil, Lisbon, Portugal
[2] Univ Lisbon, Fac Med Dent, Oral Biol Res Grp, Lisbon, Portugal
[3] Univ Lisbon, Fac Med Dent, LIBPhys FCT UID FIS 04559 2013, Lisbon, Portugal
[4] Univ Fed Santa Catarina, Operat Dent Dept, Florianopolis, SC, Brazil
[5] Univ Lisbon, Fac Med Dent, Oral Surg & Implant Dent Dept, Lisbon, Portugal
[6] Implantol Inst, Dept Oral Surg & Implant Dent, Lisbon, Portugal
关键词
analog-digital conversion [L01; 224; 230; 260; 280; 080; dental implants [E06; 780; 346; 593; dental impression materials [D25; 339; 334; dental impression technique [E06; 912; 130; stereolithography [L01; 108; 150; 500; software [L01; 900; EMERGENCE PROFILE; ACCURACY; AESTHETICS; CROWNS; EXTRACTION; PLACEMENT; IMMEDIATE; PRECISION;
D O I
10.1111/jerd.12481
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective Comparison of soft tissue replication between conventional and digital impressions for definitive single unit implant rehabilitation in the esthetic zone. Materials and Methods Six patients were recruited according to inclusion criteria for this cross-over pilot study and submitted to a conventional silicone implant impression with customized coping and a digital impression with an intraoral scanner. Stereolithography files obtained from the same patient were superimposed with appropriate software and trueness evaluated between methods at predetermined locations (56 in hard and soft tissues and 18 in the emergence profile, per patient). Results were presented as mean root mean square (RMS) +/- 95% confidence interval and effect size calculated with Hedges' g +/- 95%. Mann-Whitney and Kruskal-Wallis were performed when appropriate and alpha was set at .05. Results Trueness between methods equated to 51.08[45.68;56.47] mu m and 60.46[52.29;68.62] mu m in hard and soft tissues, respectively. Soft tissue replication by intraoral scanner acquisition corresponded to a statistically significant RMS of 243.89[209.15;278.63] mu m equating to a Hedges' g of 1.52[1.22;1.82] which corresponded to a large effect size. Conclusions The proposed method could be considered for soft tissues assessment and the results suggest that intraoral impression techniques produce statistically significant changes in peri-implant soft tissue replication, although below the clinically detectable threshold. Clinical Significance The proposed technique allows for the 3D determination of peri-implant tissues changes in digital models with higher sensitivity than visual techniques, thus presenting itself as a promising alternative in clinical studies and that the use of an intraoral scanner obtained significant differences in the soft tissue emergence profile replication when compared with the gold standard.
引用
收藏
页码:359 / 368
页数:10
相关论文
共 51 条
[1]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[2]   Examination of the Position Accuracy of Implant Abutments Reproduced by Intra-Oral Optical Impression [J].
Ajioka, Hitoshi ;
Kihara, Hidemichi ;
Odaira, Chikayuki ;
Kobayashi, Takuya ;
Kondo, Hisatomo .
PLOS ONE, 2016, 11 (10)
[3]  
Alsharbaty MHM, 2018, J PROSTHODONT
[4]   A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction [J].
Anh, Ji-won ;
Park, Ji-Man ;
Chun, Youn-Sic ;
Kim, Miae ;
Kim, Minji .
KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (01) :3-12
[5]   Many faces of the minimal clinically important difference (MCID): a literature review and directions for future research [J].
Beaton, DE ;
Boers, M ;
Wells, GA .
CURRENT OPINION IN RHEUMATOLOGY, 2002, 14 (02) :109-114
[6]   Systematic review of parameters and methods for the professional assessment of aesthetics in dental implant research [J].
Benic, Goran I. ;
Wolleb, Karin ;
Sancho-Puchades, Manuel ;
Haemmerle, Christoph H. F. .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 :160-192
[7]   Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review [J].
Bohner, Lauren ;
Gamba, Diego Diaz ;
Hanisch, Marcel ;
Marcio, Bruno Silva ;
Tortamano Neto, Pedro ;
Lagana, Dalva Cruz ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02) :246-251
[8]   Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts [J].
Buda, Michele ;
Bratos, Manuel ;
Sorensen, John A. .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06) :913-918
[9]   Esthetic Outcomes Following Immediate and Early Implant Placement in the Anterior Maxilla-A Systematic Review [J].
Chen, Stephen T. ;
Buser, Daniel .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :186-215
[10]   Esthetic assessments in implant dentistry: objective and subjective criteria for clinicians and patients [J].
Cosyn, Jan ;
Thoma, Daniel S. ;
Hammerle, Christoph H. F. ;
De Bruyn, Hugo .
PERIODONTOLOGY 2000, 2017, 73 (01) :193-202