摘要
An Ivalon-plug (PDA-plug) has been developed for transvenous closure of patent ductus arteriosus. It can be introduced into the ductus through standard venous sheaths with a diameter of 8-16 French. The plug is fixed in its target position by means of four distal (aortal) and two proximal (pulmonary) nitinol stnrts. In case of malpositioning the system can be pulled back into and retrieved through the sheath. In animal experiments endothelialization of the implanted material was demonstrated. PDA-closure was attempted in 58 patient; the procedure was successful in 57 cases; a residual ductal flow was present in eight patients. During a follow-up of up to 24 months there were no complications.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 18 条
[1]  
CAMPBELL M, 1968, BRIT HEART J, V30, P4
[2]   Echocardiographic and radionuclide pulmonary blood flow patterns after transcatheter closure of patent ductus arteriosus [J].
Dessy, H ;
Hermus, JPS ;
vandenHeuvel, F ;
Oei, HY ;
Krenning, EP ;
Hess, J .
CIRCULATION, 1996, 94 (02) :126-129
[3]   Transvenous transcatheter closure of a persistent ductus arteriosus with an Ivalon(R) plug [J].
Fassbender, D ;
Seggewiss, H ;
Schmidt, HK ;
Gleichmann, U .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 121 (20) :653-657
[4]   CLINICAL OUTCOMES AND COSTS OF TRANSCATHETER AS COMPARED WITH SURGICAL CLOSURE OF PATENT DUCTUS-ARTERIOSUS [J].
GRAY, DT ;
FYLER, DC ;
WALKER, AM ;
WEINSTEIN, MC ;
CHALMERS, TC .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (21) :1517-1523
[5]   TRANSCATHETER OCCLUSION OF THE PERSISTENTLY PATENT DUCTUS-ARTERIOSUS - 40-MONTH FOLLOW-UP AND PREVALENCE OF RESIDUAL SHUNTING [J].
HOSKING, MCK ;
BENSON, LN ;
MUSEWE, N ;
DYCK, JD ;
FREEDOM, RM .
CIRCULATION, 1991, 84 (06) :2313-2317
[6]   EXPERIENCE WITH 205 PROCEDURES OF TRANSCATHETER CLOSURE OF DUCTUS-ARTERIOSUS IN 182 PATIENTS, WITH SPECIAL REFERENCE TO RESIDUAL SHUNTS AND LONG-TERM FOLLOW-UP [J].
KHAN, MAA ;
YOUSEF, SA ;
MULLINS, CE ;
SAWYER, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (06) :1721-1727
[7]  
Porstmann W, 1967, Thoraxchir Vask Chir, V15, P199
[8]   TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH ADJUSTABLE BUTTONED DEVICE - INITIAL CLINICAL-EXPERIENCE [J].
RAO, PS ;
SIDERIS, EB ;
HADDAD, J ;
REY, C ;
HAUSDORF, G ;
WILSON, AD ;
SMITH, PA ;
CHOPRA, PS .
CIRCULATION, 1993, 88 (03) :1119-1126
[9]   TRANSCATHETER TREATMENT OF CONGENITAL HEART-DISEASE [J].
RASHKIND, WJ .
CIRCULATION, 1983, 67 (04) :711-716
[10]  
REDEL DA, 1994, Z KARDIOL S2, V83, P80