Spot-scanning proton therapy for rhabdomyosarcomas of early childhood. First experiences at PSI

被引:16
|
作者
Timmermann, Beate [1 ]
Schuck, Andreas
Niggli, Felix
Weiss, Markus
Lomax, Anthony
Goitein, Gudrun
机构
[1] Paul Scherrer Inst, Abteilung Strahlenmed, Programm Protonen Therapie, WPTA 103, CH-5232 Villigen, Switzerland
[2] Univ Munster, Abt Strahlentherapie & Radioonkol, D-4400 Munster, Germany
[3] Univ Zurich, Kinderkliniken, Abteilung Onkol, Zurich, Switzerland
[4] Univ Zurich, Kinderkliniken Zurich, Abteilung Anasthesie, Zurich, Switzerland
关键词
protons; soft-tissue tumors; irradiation; children;
D O I
10.1007/s00066-006-1592-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the feasibility and acute toxicity of spot-scanning proton therapy under deep sedation in young children with rhabdomyosarcomas (RMS). Patients and Methods: Since 2004, children requiring sedation can be admitted for proton therapy at Paul Scherrer Institute (PSI), Villigen, Switzerland. Children under 5 years of age with RMS of the head and the trunk were analyzed. All children were enrolled in a multidisciplinary treatment protocol and prospective, standardized evaluation of side effects was performed. Results: Nine children were included aged 0.9-3.8 years (embryonal RMS in six, and alveolar, undifferentiated or nonclassified in one each). The tumor site was parameningeat (n = 4), orbital (n = 3), head and neck (n = 1), and prostate (n = 1). All children were in IRS group III. Total proton dose was 46-54 CGE (cobalt-gray equivalent). Only the myelotoxicity exceeded grade 3 or 4 (RTOG/EORTC). Conclusion: Proton therapy for RMS in early children is feasible and well tolerated. The prospective standardized evaluation of toxicity and quality of life needs to be continued.
引用
收藏
页码:653 / 659
页数:7
相关论文
共 29 条
  • [1] Protonentherapie mit „Spot-Scanning“ bei Rhabdomyosarkomen im frühen KindesalterErste Erfahrungen am PSI“Spot-Scanning” Proton Therapy for Rhabdomyosarcomas of Early Childhood. First Experiences at PSI
    Beate Timmermann
    Andreas Schuck
    Felix Niggli
    Markus Weiss
    Anthony Lomax
    Gudrun Goitein
    Strahlentherapie und Onkologie, 2006, 182 : 653 - 659
  • [2] Spot-scanning proton therapy for malignant soft tissue tumors in childhood: First experiences at the Paul Scherrer Institute
    Timmermann, Beate
    Schuck, Andreas
    Niggli, Felix
    Weiss, Markus
    Lomax, Antony Jonathan
    Pedroni, Eros
    Coray, Adolf
    Jermann, Martin
    Rutz, Hans Peter
    Goitein, Gudrun
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 497 - 504
  • [3] Spot-scanning proton therapy for early breast cancer in free breathing versus deep inspiration breath-hold
    Stick, Line Bjerregaard
    Nielsen, Louise Laerke
    Trinh, Cecilia Bui
    Bahij, Ihsan
    Jensen, Maria Fuglsang
    Kronborg, Camilla Jen- senius Skovhus
    Petersen, Stine Elleberg
    Thai, Linh My Hoang
    Martinsen, May-Lin
    Precht, Helle
    Offersen, Birgitte Vrou
    ACTA ONCOLOGICA, 2024, 63 : 56 - 61
  • [4] A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept
    Hyer, Daniel E.
    Hill, Patrick M.
    Wang, Dongxu
    Smith, Blake R.
    Flynn, Ryan T.
    MEDICAL PHYSICS, 2014, 41 (09)
  • [5] Improving dosimetric outcome for hippocampus and cochlea sparing whole brain radiotherapy using spot-scanning proton arc therapy
    Ding, Xuanfeng
    Zhou, Jun
    Li, Xiaoqiang
    Blas, Kevin
    Liu, Gang
    Wang, Yinan
    Qin, An
    Chinnaiyan, Prakash
    Yan, Di
    Stevens, Craig
    Grills, Inga
    Kabolizadeh, Peyman
    ACTA ONCOLOGICA, 2019, 58 (04) : 483 - 490
  • [6] Spot-Scanning Proton Radiation Therapy for Pediatric Chordoma and Chondrosarcoma: Clinical Outcome of 26 Patients Treated at Paul Scherrer Institute
    Rombi, Barbara
    Ares, Carmen
    Hug, Eugen B.
    Schneider, Ralf
    Goitein, Gudrun
    Staab, Adrian
    Albertini, Francesca
    Bolsi, Alessandra
    Lomax, Antony J.
    Timmermann, Beate
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03): : 578 - 584
  • [7] Validation of Beam Accuracy of a Gated Spot-Scanning Proton Therapy System with Real-Time Tumor-Tracking at Hokkaido University
    Yamada, T.
    Matsuura, T.
    Toramatsu, C.
    Takao, S.
    Nihongi, H.
    Miyamoto, N.
    Shimizu, S.
    Takayanagi, T.
    Umezawa, M.
    Matsuda, K.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 304 - +
  • [8] Prospective study to evaluate the safety of the world-first spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy system
    Nishioka, Kentaro
    Prayongrat, Anussara
    Ono, Kota
    Onodera, Shunsuke
    Hashimoto, Takayuki
    Katoh, Norio
    Inoue, Tetsuya
    Kinoshita, Rumiko
    Yasuda, Koichi
    Mori, Takashi
    Onimaru, Rikiya
    Shirato, Hiroki
    Shimizu, Shinichi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 : I63 - I71
  • [9] Whole-pelvic radiotherapy with spot-scanning proton beams for uterine cervical cancer: a planning study
    Hashimoto, Shingo
    Shibamoto, Yuta
    Iwata, Hiromitsu
    Ogino, Hiroyuki
    Shibata, Hiroki
    Toshito, Toshiyuki
    Sugie, Chikao
    Mizoe, Jun-etsu
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (05) : 524 - 532
  • [10] Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system
    Courneyea, Lorraine
    Beltran, Chris
    Tseung, Hok Seum Wan Chan
    Yu, Juan
    Herman, Michael G.
    MEDICAL PHYSICS, 2014, 41 (06)