A High-Precision Machine Learning Algorithm to Classify Left and Right Outflow Tract Ventricular Tachycardia

被引:19
|
作者
Zheng, Jianwei [1 ]
Fu, Guohua [2 ]
Abudayyeh, Islam [3 ]
Yacoub, Magdi [4 ]
Chang, Anthony [5 ]
Feaster, William W. [5 ]
Ehwerhemuepha, Louis [5 ]
El-Askary, Hesham [1 ,6 ]
Du, Xianfeng [2 ]
He, Bin [2 ]
Feng, Mingjun [2 ]
Yu, Yibo [2 ]
Wang, Binhao [2 ]
Liu, Jing [2 ]
Yao, Hai [7 ]
Chu, Huimin [2 ]
Rakovski, Cyril [1 ]
机构
[1] Chapman Univ, Computat & Data Sci, Orange, CA USA
[2] Ningbo First Hosp Zhejiang Univ, Dept Cardiol, Hangzhou, Peoples R China
[3] Loma Linda Univ, Dept Cardiol, Loma Linda, CA USA
[4] Imperial Coll London, Harefield Heart Sci Ctr, London, England
[5] CHOC Childrens Hosp, Orange, CA USA
[6] Alexandria Univ, Dept Environm Sci, Fac Sci, Alexandria, Egypt
[7] Zhejiang Cachet Jetboom Med Devices Co Ltd, Hangzhou, Peoples R China
关键词
outflow tract ventricular tachycardia; catheter ablation; electrocardiography; classification; artificial intelligence algorithm; OPTIMAL ABLATION SITE; ELECTROCARDIOGRAPHIC CRITERION; ECG ALGORITHM; ORIGIN; TRANSITION; LEAD;
D O I
10.3389/fphys.2021.641066
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Multiple algorithms based on 12-lead ECG measurements have been proposed to identify the right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT) locations from which ventricular tachycardia (VT) and frequent premature ventricular complex (PVC) originate. However, a clinical-grade machine learning algorithm that automatically analyzes characteristics of 12-lead ECGs and predicts RVOT or LVOT origins of VT and PVC is not currently available. The effective ablation sites of RVOT and LVOT, confirmed by a successful ablation procedure, provide evidence to create RVOT and LVOT labels for the machine learning model. Methods We randomly sampled training, validation, and testing data sets from 420 patients who underwent successful catheter ablation (CA) to treat VT or PVC, containing 340 (81%), 38 (9%), and 42 (10%) patients, respectively. We iteratively trained a machine learning algorithm supplied with 1,600,800 features extracted via our proprietary algorithm from 12-lead ECGs of the patients in the training cohort. The area under the curve (AUC) of the receiver operating characteristic curve was calculated from the internal validation data set to choose an optimal discretization cutoff threshold. Results The proposed approach attained the following performance: accuracy (ACC) of 97.62 (87.44-99.99), weighted F1-score of 98.46 (90-100), AUC of 98.99 (96.89-100), sensitivity (SE) of 96.97 (82.54-99.89), and specificity (SP) of 100 (62.97-100). Conclusions The proposed multistage diagnostic scheme attained clinical-grade precision of prediction for LVOT and RVOT locations of VT origin with fewer applicability restrictions than prior studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] An electrocardiographic scoring system for distinguishing right ventricular outflow tract arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy from idiopathic ventricular tachycardia
    Hoffmayer, Kurt S.
    Bhave, Prashant D.
    Marcus, Gregory M.
    James, Cynthia A.
    Tichnell, Crystal
    Chopra, Nagesh
    Moxey, Laura
    Krahn, Andrew D.
    Dixit, Sanjay
    Stevenson, William
    Calkins, Hugh
    Badhwar, Nitish
    Gerstenfeld, Edward P.
    Scheinman, Melvin M.
    HEART RHYTHM, 2013, 10 (04) : 477 - 482
  • [42] Catheter Ablation of Repetitive Monomorphic Ventricular Tachycardia From Left Ventricular Outflow Tract Guided by Unipolar Mapping
    Antonio Asso
    Elisa De Pascual
    Mercedes López
    Rosa Rodriguez
    Juan Casado
    Luis Placer
    Journal of Interventional Cardiac Electrophysiology, 2000, 4 : 435 - 439
  • [43] Catheter ablation of repetitive monomorphic ventricular tachycardia from left ventricular outflow tract guided by unipolar mapping
    Asso, A
    De Pascual, E
    López, M
    Rodriguez, R
    Casado, J
    Placer, L
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (02) : 435 - 439
  • [44] Changes in autonomic nervous activity after catheter ablation of right ventricular outflow tract tachycardia
    Mizumaki, K
    Fujiki, A
    Usui, M
    Shimono, M
    Hayashi, H
    Nagasawa, H
    Inoue, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (09): : 697 - 703
  • [45] Spatial resolution of pacemapping and activation mapping in patients with idiopathic right ventricular outflow tract tachycardia
    Azegami, K
    Wilber, DJ
    Arruda, M
    Lin, AC
    Denman, RA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (08) : 823 - 829
  • [46] Clinical usefulness of a multielectrode basket catheter for idiopathic ventricular tachycardia originating from right ventricular outflow tract
    Aiba, T
    Shimizu, W
    Taguchi, A
    Suyama, K
    Kurita, T
    Aihara, N
    Kamakura, S
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (05) : 511 - 517
  • [47] Radiofrequency catheter ablation of idiopathic left ventricular outflow tract tachycardia: Utility of intracardiac echocardiography
    Lamberti, F
    Calo', L
    Pandozi, C
    Castro, A
    Loricchio, ML
    Boggi, A
    Toscano, S
    Ricci, R
    Drago, F
    Santini, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (05) : 529 - 535
  • [48] The V2 Transition Ratio A New Electrocardiographic Criterion for Distinguishing Left From Right Ventricular Outflow Tract Tachycardia Origin
    Betensky, Brian P.
    Park, Robert E.
    Marchlinski, Francis E.
    Hutchinson, Matthew D.
    Garcia, Fermin C.
    Dixit, Sanjay
    Callans, David J.
    Cooper, Joshua M.
    Bala, Rupa
    Lin, David
    Riley, Michael P.
    Gerstenfeld, Edward P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (22) : 2255 - 2262
  • [49] Radiofrequency catheter ablation at the left coronary cusp in treatment of repetitive monomorphic tachycardia of the left ventricular outflow tract
    Tang, K
    Ma, J
    Zhang, S
    Chu, JM
    Zhang, KJ
    Wang, FZ
    Chen, X
    CHINESE MEDICAL JOURNAL, 2004, 117 (02) : 168 - 171
  • [50] Cooled tip ablation of left ventricular outflow tract tachycardia through the aortic sinus of valsalva
    Kurzidim, K
    Neumann, T
    Vukajlovic, D
    Güttler, N
    Sperzel, J
    Bahavar, H
    Hamm, CW
    Pitschner, HF
    ZEITSCHRIFT FUR KARDIOLOGIE, 2002, 91 (10): : 796 - 805