A High-Precision Machine Learning Algorithm to Classify Left and Right Outflow Tract Ventricular Tachycardia

被引:19
|
作者
Zheng, Jianwei [1 ]
Fu, Guohua [2 ]
Abudayyeh, Islam [3 ]
Yacoub, Magdi [4 ]
Chang, Anthony [5 ]
Feaster, William W. [5 ]
Ehwerhemuepha, Louis [5 ]
El-Askary, Hesham [1 ,6 ]
Du, Xianfeng [2 ]
He, Bin [2 ]
Feng, Mingjun [2 ]
Yu, Yibo [2 ]
Wang, Binhao [2 ]
Liu, Jing [2 ]
Yao, Hai [7 ]
Chu, Huimin [2 ]
Rakovski, Cyril [1 ]
机构
[1] Chapman Univ, Computat & Data Sci, Orange, CA USA
[2] Ningbo First Hosp Zhejiang Univ, Dept Cardiol, Hangzhou, Peoples R China
[3] Loma Linda Univ, Dept Cardiol, Loma Linda, CA USA
[4] Imperial Coll London, Harefield Heart Sci Ctr, London, England
[5] CHOC Childrens Hosp, Orange, CA USA
[6] Alexandria Univ, Dept Environm Sci, Fac Sci, Alexandria, Egypt
[7] Zhejiang Cachet Jetboom Med Devices Co Ltd, Hangzhou, Peoples R China
关键词
outflow tract ventricular tachycardia; catheter ablation; electrocardiography; classification; artificial intelligence algorithm; OPTIMAL ABLATION SITE; ELECTROCARDIOGRAPHIC CRITERION; ECG ALGORITHM; ORIGIN; TRANSITION; LEAD;
D O I
10.3389/fphys.2021.641066
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Multiple algorithms based on 12-lead ECG measurements have been proposed to identify the right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT) locations from which ventricular tachycardia (VT) and frequent premature ventricular complex (PVC) originate. However, a clinical-grade machine learning algorithm that automatically analyzes characteristics of 12-lead ECGs and predicts RVOT or LVOT origins of VT and PVC is not currently available. The effective ablation sites of RVOT and LVOT, confirmed by a successful ablation procedure, provide evidence to create RVOT and LVOT labels for the machine learning model. Methods We randomly sampled training, validation, and testing data sets from 420 patients who underwent successful catheter ablation (CA) to treat VT or PVC, containing 340 (81%), 38 (9%), and 42 (10%) patients, respectively. We iteratively trained a machine learning algorithm supplied with 1,600,800 features extracted via our proprietary algorithm from 12-lead ECGs of the patients in the training cohort. The area under the curve (AUC) of the receiver operating characteristic curve was calculated from the internal validation data set to choose an optimal discretization cutoff threshold. Results The proposed approach attained the following performance: accuracy (ACC) of 97.62 (87.44-99.99), weighted F1-score of 98.46 (90-100), AUC of 98.99 (96.89-100), sensitivity (SE) of 96.97 (82.54-99.89), and specificity (SP) of 100 (62.97-100). Conclusions The proposed multistage diagnostic scheme attained clinical-grade precision of prediction for LVOT and RVOT locations of VT origin with fewer applicability restrictions than prior studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Impact of earliest activation site location in the septal right ventricular outflow tract for identification of left vs right outflow tract origin of idiopathic ventricular arrhythmias
    Acosta, Juan
    Penela, Diego
    Herczku, Csaba
    Macias, Yolanda
    Andreu, David
    Fernandez-Armenta, Juan
    Cipolletta, Laura
    Diaz, Andres
    Korshunov, Viatcheslav
    Brugada, Josep
    Mont, Lluis
    Cabrera, Jose A.
    Sanchez-Quintana, Damian
    Berruezo, Antonio
    HEART RHYTHM, 2015, 12 (04) : 726 - 734
  • [22] Electrical isolation of the right ventricular outflow tract in idiopathic ventricular tachycardia: a case report
    Popa, Miruna A.
    Hessling, Gabriele
    Deisenhofer, Isabel
    Bourier, Felix
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (03)
  • [23] Human Model Simulating Right Ventricular Outflow Tract Tachycardia by High-Frequency Stimulation in the Left Pulmonary Artery: Autonomics and Idiopathic Ventricular Arrhythmias
    Hasdemir, Can
    Alp, Alpay
    Aydin, Mehmet
    Can, Levent H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (07) : 759 - 763
  • [24] Localization of optimal ablation site of idiopathic ventricular tachycardia from right and left ventricular outflow tract by body surface ECG
    Kamakura, S
    Shimizu, W
    Matsuo, K
    Taguchi, A
    Suyama, K
    Kurita, T
    Aihara, N
    Ohe, T
    Shimomura, K
    CIRCULATION, 1998, 98 (15) : 1525 - 1533
  • [25] Adenosine-insensitive right ventricular tachycardia: Novel variant of idiopathic outflow tract tachycardia
    Cheung, Jim W.
    Ip, James E.
    Yarlagadda, Ravi K.
    Liu, Christopher F.
    Thomas, George
    Xu, Linna
    Wilkes, David
    Markowitz, Steven M.
    Lerman, Bruce B.
    HEART RHYTHM, 2014, 11 (10) : 1770 - 1778
  • [26] Preexcited Tachycardia Mimicking Outflow Tract Ventricular Tachycardia Ablated from the Left Coronary Cusp
    Shenthar, Jayaprakash
    Rai, Maneesh K.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (06) : 653 - 656
  • [27] Right Ventricular Outflow Tract Tachycardia: a Common Rhythm due to an Uncommon Etiology
    Pirimoglu, Berhan
    Duran, Alper
    Duran, Cihan
    EURASIAN JOURNAL OF MEDICINE, 2019, 51 (02) : 203 - 205
  • [28] Distribution of Successful Ablation Sites of Idiopathic Right Ventricular Outflow Tract Tachycardia
    Yamashina, Yoshihiro
    Yagi, Tetsuo
    Namekawa, Akio
    Ishida, Akihiko
    Sato, Hirokazu
    Nakagawa, Takashi
    Sakuramoto, Manjirou
    Sato, Eiji
    Yambe, Tomoyuki
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (06): : 727 - 733
  • [29] Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia
    Thornton, AS
    Jordaens, LJ
    HEART RHYTHM, 2006, 3 (06) : 691 - 696
  • [30] Automated Template Matching to Pinpoint the Origin of Right Ventricular Outflow Tract Tachycardia
    Kurosaki, Kenji
    Nogami, Akihiko
    Sakamaki, Mihiko
    Kowase, Shinya
    Sugiyasu, Aiko
    Oginosawa, Yasushi
    Kubota, Shoichi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S47 - S51