Original Preoperative Localization Technique of Parathyroid Adenomas by 3-Dimensional Virtual Neck Exploration

被引:3
|
作者
Ignat, Mihaela [1 ,2 ]
Perouse, Madeleine [1 ]
Lefebvre, Francois [3 ]
Kadoche, Deborah [1 ,2 ]
Imperiale, Alessio [4 ,5 ]
Swanstrom, Lee [2 ]
Vix, Michel [1 ,2 ]
Mutter, Didier [1 ,2 ]
机构
[1] Univ Hosp Strasbourg, Dept Digest & Endocrine Surg, 1 Pl Hop, F-67091 Strasbourg, France
[2] IHU IRCAD, Inst Image Guided Surg, Strasbourg, France
[3] Univ Hosp Strasbourg, Dept Med Informat, Strasbourg, France
[4] ICANS, Med Nucl & Imagerie Mol, Strasbourg, France
[5] Unistra, Inst Pluridisciplinaire Hubert Curien IPHC, CNRS, Imagerie Mol,DRHIM,UMR, Strasbourg, France
关键词
primary hyperparathyroidism; minimally invasive parathyroidectomy; three-dimensional imaging; 3D virtual neck exploration; cohort study; diagnostic accuracy study; technetium Tc-99m sestamibi;
D O I
10.1177/15533506211001236
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective. Preoperative imaging in primary hyperparathyroidism (PHPT) is essential for planning of parathyroidectomy-particularly for selection of a minimally invasive approach. The objective of this cohort study was to evaluate the diagnostic precision of 3D virtual neck exploration (3D-VNE), to evaluate its impact on choice of surgical approach, and to document the correlation with long-term outcomes. Methods. 235 consecutive patients with PHPT were studied (January 2014 to December 2018), with 6-month follow-up. 220 patients had a preoperative computed tomography (CT), 172 of these had a 3D-VNE based on the CT, and 226 patients had a Tc-99m sestamibi scan. Results. Sensitivity of exact, per gland, adenoma localization was 57.09% (95% CI: 50.85-63.10%) for nonspecialized radiologist interpretation of CT scan, 58.17% (95% CI: 51.99-64.10%) for Tc-99m sestamibi scan, and 90.21% (95% CI: 85.21-93.64%) for 3D-VNE, and thereby favoring 3D-VNE compared to CT scan alone (OR 34.5, 95% CI: 9.19-290.56%, P < 2.2 x 10(-16)) and to Tc-99m sestamibi scan (OR 16.25, 95% CI: 6.05-61.42%, P = 3.1 x 10(-15)). Specificity was 87.38% for CT scan, 86.36% for 3D-VNE, and 90% for Tc-99m sestamibi scan (P > .05). The cure rate was 100%. The long-term recurrence rate (RR) was 2.978%. The RR was 1.324% in the video-assisted parathyroidectomy group of 151 patients and 5.952% in the group of 84 patients with cervicotomy (P = .0459). Conclusion. CT-based 3D-VNE proved to be the most accurate localizing study in PHPT and aided in selecting patients for targeted minimally invasive parathyroidectomy, which was associated with the lower recurrence rate. 3D-VNE could be proposed as a first-line imaging study in patients with PHPT.
引用
收藏
页码:261 / 271
页数:11
相关论文
共 41 条
  • [1] Preoperative localization of parathyroid adenomas
    Avitia, Sofia
    Osborne, Ryan F.
    ENT-EAR NOSE & THROAT JOURNAL, 2009, 88 (04) : 862 - +
  • [2] Four-dimensional Computed Tomography for Preoperative Localization of Parathyroid Adenomas
    Zeina, Abdel-Rauf
    Nakar, Helit
    Reindorp, Nadir
    Nachtigal, Alicia
    Krausz, Michael M.
    Ashkenazi, Itamar
    Shapira-Rootman, Mika
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2017, 19 (04): : 216 - 220
  • [3] Preoperative Localization of Parathyroid Adenomas Using 4-Dimensional Computed Tomography: A Pictorial Essay
    Ellika, Shehanaz
    Patel, Suresh
    Aho, Todd
    Marin, Horia
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (03): : 258 - 268
  • [4] Preoperative and Intraoperative Methods of Parathyroid Gland Localization and the Diagnosis of Parathyroid Adenomas
    Baj, Jacek
    Sitarz, Robert
    Lokaj, Marek
    Forma, Alicja
    Czeczelewski, Marcin
    Maani, Amr
    Garruti, Gabriella
    MOLECULES, 2020, 25 (07):
  • [5] The Value of Preoperative and Intraoperative Ultrasound in the Localization of Intrathyroidal Parathyroid Adenomas
    Zhao, Wei
    Lu, Ruigang
    Yin, Li
    Wei, Bojun
    Jin, Mulan
    Zhang, Chun
    Guo, Ruijun
    Lv, Xiuzhang
    JOURNAL OF INVESTIGATIVE SURGERY, 2022, 35 (04) : 752 - 757
  • [6] The role of colour Doppler ultrasonography in the preoperative localization of parathyroid adenomas
    Mohammadi, Afshin
    Mooudi, Farzad
    Ghasemi-rad, Mohammad
    ENDOCRINE JOURNAL, 2012, 59 (05) : 375 - 382
  • [7] Diagnostic value of endoscopic ultrasonography for preoperative localization of parathyroid adenomas
    Reyhan Ersoy
    Osman Ersoy
    Berna Evranos Ogmen
    Sefika Burcak Polat
    Mehmet Kilic
    Nilufer Yildirim
    Levent Ozturk
    Bekir Cakir
    Endocrine, 2014, 47 : 221 - 226
  • [8] Diagnostic value of endoscopic ultrasonography for preoperative localization of parathyroid adenomas
    Ersoy, Reyhan
    Ersoy, Osman
    Ogmen, Berna Evranos
    Polat, Sefika Burcak
    Kilic, Mehmet
    Yildirim, Nilufer
    Ozturk, Levent
    Cakir, Bekir
    ENDOCRINE, 2014, 47 (01) : 221 - 226
  • [9] Accurate Preoperative Localization of Parathyroid Adenomas With C-11 Methionine PET/CT
    Weber, Theresia
    Maier-Funk, Clemens
    Ohlhauser, Dagmar
    Hillenbrand, Andreas
    Cammerer, Gregor
    Barth, Thomas F.
    Henne-Bruns, Doris
    Boehm, Bernhard O.
    Reske, Sven N.
    Luster, Markus
    ANNALS OF SURGERY, 2013, 257 (06) : 1124 - 1128
  • [10] Virtual Neck Exploration for Parathyroid Adenomas A First Step Toward Minimally Invasive Image-Guided Surgery
    D'Agostino, Jacopo
    Wall, James
    Soler, Luc
    Vix, Michel
    Duh, Quan-Yang
    Marescaux, Jacques
    JAMA SURGERY, 2013, 148 (03) : 232 - 238