Multicenter Study of Central Venous Oxygen Saturation (ScvO2) as a Predictor of Mortality in Patients With Sepsis

被引:185
|
作者
Pope, Jennifer V. [1 ]
Jones, Alan E. [4 ]
Gaieski, David F. [6 ]
Arnold, Ryan C. [5 ]
Trzeciak, Stephen [5 ,7 ]
Shapiro, Nathan I. [1 ,2 ,3 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Emergency Med, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Vasc Biol Res Ctr, Boston, MA 02215 USA
[3] Beth Israel Deaconess Med Ctr, Div Mol & Vasc Med, Boston, MA 02215 USA
[4] Carolinas Med Ctr, Dept Emergency Med, Charlotte, NC 28203 USA
[5] Cooper Univ Hosp, Dept Emergency Med, Camden, NJ USA
[6] Hosp Univ Penn, Dept Emergency Med, Camden, NJ USA
[7] Cooper Univ Hosp, Div Crit Care Med, Camden, NJ USA
基金
美国国家卫生研究院;
关键词
GOAL-DIRECTED THERAPY; SEPTIC SHOCK; MICROCIRCULATORY PERFUSION; DYSFUNCTION; PROTOCOL;
D O I
10.1016/j.annemergmed.2009.08.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: Abnormal (both low and high) central venous saturation (ScvO(2)) is associated with increased mortality in emergency department (ED) patients with suspected sepsis. Methods: This was a secondary analysis of 4 prospectively collected registries of ED patients treated with early goal-directed therapy-based sepsis resuscitation protocols from 4 urban tertiary care hospitals. Inclusion criteria were sepsis, hypoperfusion defined by systolic blood pressure less than 90 mm Hg or lactate level greater than or equal to 4 mmol/L, and early goal-directed therapy treatment. ScvO(2) levels were stratified into 3 groups: hypoxia (ScvO(2) <70%); normoxia (ScvO(2) 71% to 89%); and hyperoxia (ScvO(2) 90% to 100%). The primary exposures were initial ScvO(2) and maximum ScvO(2) achieved, with the primary outcome as inhospital mortality. Multivariate analysis was performed. Results: There were 619 patients who met criteria and were included. For the maximum ScvO(2), compared with the mortality rate in the normoxia group of 96 of 465 (21%; 95% confidence interval [CI] 17% to 25%), both the hypoxia mortality rate, 25 of 62 (40%; 95% CI 29% to 53%) and hyperoxia mortality rate, 31 of 92 (34%; 95% CI 25% to 44%) were significantly higher, which remained significant in a multivariate modeling. When the initial ScvO(2) measurement was analyzed in a multivariate model, only hyperoxia was significantly higher. Conclusion: The maximum ScvO(2) value achieved in the ED (both abnormally low and high) was associated with increased mortality. In multivariate analysis for initial ScvO(2), the hyperoxia group was associated with increased mortality, but not the hypoxia group. This study suggests that future research aimed at targeting methods to normalize high ScvO(2) values by therapies that improve microcirculatory flow or mitochondrial dysfunction may be warranted. [Ann Emerg Med. 2010;55:40-46.]
引用
收藏
页码:40 / 46
页数:7
相关论文
共 50 条
  • [1] CENTRAL VENOUS OXYGEN SATURATION (SCVO2): THE PHYSIOLOGIC TRANSFUSION TRIGGER?
    Kocsi, S.
    Koczka, I.
    Soos, K.
    Frei, N.
    Molnar, Z.
    INTENSIVE CARE MEDICINE, 2010, 36 : S351 - S351
  • [2] USE OF MONITORING CENTRAL VENOUS OXYGEN SATURATION (SCVO2) IN CARDIAC SURGERY
    Gonzalez Lopez, M. T.
    Martinez Ruiz, J.
    Montalban Moreno, B.
    Jimenez Jimenez, V.
    Garvi Lopez, M.
    Jimenez Tortosa, R.
    Rodriguez Rubio, L.
    Giron Lacasa, M.
    Aladren Perez, M.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 19 - 19
  • [3] CENTRAL VENOUS OXYGEN SATURATION (SCVO2) IS POORLY PREDICTED BY SERUM LACTATE IN ICU PATIENTS
    Bisarya, Roshan
    Shaath, Deena
    Pirzad, Arman
    Satterwhite, Lewis
    Pitts, Lucas
    Simpson, Steven
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 2 - 2
  • [4] The relationship between central venous oxygen saturation (scvo2) and oxygen debt in normovolaemic anaemia
    Kocsi, S.
    Demeter, G.
    Soos, K.
    Nagy, E.
    Erces, D.
    Kaszaki, J.
    Molnar, Z.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 : 4 - 4
  • [5] Severe sepsis complicated by right ventricular infarction (RVI): Making a diagnosis with central venous oxygen saturation (SCVO2)
    Verceles, A
    Sebastian, JC
    Ko, A
    Gopinathannair, R
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A180 - A180
  • [6] Comparison of clinical outcomes between intermittent and continuous monitoring of central venous oxygen saturation (ScvO2) in patients with severe sepsis and septic shock: a pilot study
    Huh, Jin Won
    Oh, Bum Jin
    Lim, Chae-Man
    Hong, Sang-Bum
    Koh, Younsuck
    EMERGENCY MEDICINE JOURNAL, 2013, 30 (11) : 906 - 909
  • [7] Low values of central venous oxygen saturation (ScvO2) during surgery and anastomotic leak of abdominal trauma patients
    Andres Isaza-Restrepo
    Jose F. Moreno-Mejia
    Juan S. Martin-Saavedra
    Milciades Ibañez-Pinilla
    World Journal of Emergency Surgery, 12
  • [8] Low values of central venous oxygen saturation (ScvO2) during surgery and anastomotic leak of abdominal trauma patients
    Isaza-Restrepo, Andres
    Moreno-Mejia, Jose F.
    Martin-Saavedra, Juan S.
    Ibanez-Pinilla, Milciades
    WORLD JOURNAL OF EMERGENCY SURGERY, 2017, 12
  • [9] Alleviating central venous oxygen saturation (ScvO2): a new approach of kidney protection after cardiac surgery?
    Honore, Patrick M.
    Jacobs, Rita
    Hendrickx, Inne
    De Waele, Elisabeth
    Duc Nam Nguyen
    Spapen, Herbert D.
    CRITICAL CARE, 2015, 19
  • [10] OPTIMIZING OXYGEN DELIVERY IN THE CRITICALLY ILL: THE UTILITY OF LACTATE AND CENTRAL VENOUS OXYGEN SATURATION (SCVO2) AS A ROADMAP OF RESUSCITATION IN SHOCK
    Joshi, Raj
    de Witt, Benjamin
    Mosier, Jarrod M.
    JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (04): : 493 - 500