Evaluation of mechanical properties of Ti-25Nb BCC porous cell structure and their association with structure porosity: A combined finite element analysis and analytical approach for orthopedic application

被引:9
作者
Chowdhury, Soham [1 ]
Anand, Amit [1 ]
Singh, Adhish [1 ]
Pal, Bidyut [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Mech Engn, PO Bot Garden, Howrah 711103, W Bengal, India
关键词
Total hip arthroplasty; finite element analysis; BCC porous micro-structures; bio-materials; titanium-25niobium; LATTICE STRUCTURES; TITANIUM-ALLOYS; BONE SCAFFOLDS; DESIGN; MICROSTRUCTURES; REPLACEMENT; BIOMATERIALS; IMPLANTS; BASE;
D O I
10.1177/09544119211011309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ti-based alloys have been commonly employed in manufacturing implants for orthopedic applications. Binary Titanium-Niobium (Ti-25Nb) alloy is a promising material for potential applications in orthopedics because of their lower elastic moduli and superior biocompatibility than the conventional Ti-based alloys. Implants with porous structures encourage bone ingrowth and reduce the effect of stress-shielding further. This study is aimed at establishing the relationship between the mechanical performance and structural parameters of porous body-centered-cubic (BCC) structures made up of Ti-25Nb (25% by wt.). Solid models of BCC porous structures were constructed (unit cell size: 2 mm; overall size: 8 x 8 x 8 mm(3)). Finite element analysis (FEA) of the BCC structures with porosity ranging from 29% to 79% (seven porosities) was conducted under tension, bending, and torsional loads. The Gibson-Ashby model and Exponential regression model were also employed to determine the stiffness of the above porous structures. The functional relationships between effective Young's modulus, effective yield strength, and porosity generated from both the models were found to match the FEA results well. Results indicated that porosity in the range of 50%-70% can be used to design graded porous stems to mimic the mechanical properties of cortical bone.
引用
收藏
页码:827 / 837
页数:11
相关论文
共 41 条
[1]   Biomechanical and bioactivity concepts of polyetheretherketone composites for use in orthopedic implantsa review [J].
Abdullah, Mohamed Ruslan ;
Goharian, Amirhossein ;
Kadir, Mohammed Rafiq Abdul ;
Wahit, Mat Uzir .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2015, 103 (11) :3689-3702
[2]  
[Anonymous], 2010, CELLULAR MAT NATURE
[3]   High-strength porous biomaterials for bone replacement: A strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints [J].
Arabnejad, Sajad ;
Johnston, R. Burnett ;
Pura, Jenny Ann ;
Singh, Baljinder ;
Tanzer, Michael ;
Pasini, Damiano .
ACTA BIOMATERIALIA, 2016, 30 :345-356
[4]   Aseptic loosening of femoral components - A review of current and future trends in materials used [J].
Bahraminasab, Marjan ;
Sahari, B. B. ;
Edwards, K. L. ;
Farahmand, Farzam ;
Arumugam, Manohar ;
Hong, Tang Sai .
MATERIALS & DESIGN, 2012, 42 :459-470
[5]   Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants [J].
Bandyopadhyay, Amit ;
Espana, Felix ;
Balla, Vamsi Krishna ;
Bose, Susmita ;
Ohgami, Yusuke ;
Davies, Neal M. .
ACTA BIOMATERIALIA, 2010, 6 (04) :1640-1648
[6]  
BURTON CV, 1981, CLIN ORTHOP RELAT R, P191
[7]  
Charnley J., 1979, LOW FRICTION ARTHROP
[8]   Microstructure design of biodegradable scaffold and its effect on tissue regeneration [J].
Chen, Yuhang ;
Zhou, Shiwei ;
Li, Qing .
BIOMATERIALS, 2011, 32 (22) :5003-5014
[9]  
Destefani J.D., 1990, Properties and Selection: Nonferrous Alloys and Special-Purpose Materials, P586, DOI [10.31399/asm.hb.v02.a0001080, DOI 10.31399/ASM.HB.V02.A0001080]
[10]   Mechanical properties of a Ti-Nb-Al shape memory alloy [J].
Fukui, Y ;
Inamura, T ;
Hosoda, H ;
Wakashima, K ;
Miyazaki, S .
MATERIALS TRANSACTIONS, 2004, 45 (04) :1077-1082