A Sensor System Based on a Field-Effect Transistor with a Nanowire Channel for the Quantitative Determination of Thyroid-Stimulating Hormone

被引:4
作者
Tsiniaikin, I. I. [1 ,2 ]
Presnova, G. V. [3 ]
Bozhev, I. V. [1 ,2 ]
Skorik, A. A. [1 ]
Rubtsova, M. Yu. [3 ]
Kamalov, A. A. [4 ]
Matskeplishvili, S. T. [4 ]
Snigirev, O. V. [1 ,2 ]
Krupenin, V. A. [1 ,2 ]
Presnov, D. E. [1 ,2 ,5 ]
机构
[1] Moscow MV Lomonosov State Univ, Cryoelect Lab, Fac Phys, Moscow 119991, Russia
[2] MSU Quantum Technol Ctr, Moscow 119991, Russia
[3] Moscow MV Lomonosov State Univ, Enzymol Div, Dept Chem, Moscow 119991, Russia
[4] Moscow MV Lomonosov State Univ, Med Res & Educ Ctr, Moscow 119192, Russia
[5] Moscow MV Lomonosov State Univ, DV Skobeltsyn Inst Nucl Phys, Moscow 119991, Russia
基金
俄罗斯科学基金会;
关键词
biosensor; nanowire; field-effect transistor; microchip; silicon on insulator; electron beam lithography; sandwich immunoassay; gold nanoparticles; thyroid-stimulating hormone;
D O I
10.3103/S002713492006020X
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Here we present an original CMOS compatible technique for fabrication a sensor system based on field-effect transistors with a nanowire channel and its application for the quantitative determination of thyroid-stimulating hormone (TSH) in model blood serum. The fabrication process is based on the reactive-ion etching of the upper layer of silicon on insulator through a mask formed by electron beam lithography. The detection is based on the registration the change in the conductivity of the transistor during the selective interaction of the analyte with specific biomolecules on its surface. There were fabricated field-effect transistors with a nanowire channel of 70-90 nm wide and 3- 5 mu m in long and a contact leads completely insulated from the analyte fluid. As the model antigen protein TSH of the pituitary gland, and as the recognition biomolecules - the specific to TSH fragments of antibodies were used, which were oriented immobilized on the nanowires surface. We carefully studied the conditions for biospecific interaction of antibodies with TSH. The detection limit of TSH was found to be 1 x 10(-4)mu IU/mL, which is significantly lower in comparison with currently used methods of standard enzyme-linked immunosorbent assay.
引用
收藏
页码:645 / 656
页数:12
相关论文
共 54 条
  • [11] Hou L, 2012, TALANTA, V738, P76, DOI [10.1016/j.aca.2012.06.013, DOI 10.1016/J.ACA.2012.06.013]
  • [12] Huang Xiaohua, 2017, Nanotheranostics, V1, P80, DOI 10.7150/ntno.18216
  • [13] Label-Free, Electrical Detection of the SARS Virus N-Protein with Nanowire Biosensors Utilizing Antibody Mimics as Capture Probes
    Ishikawa, Fumiaki N.
    Chang, Hsiao-Kang
    Curreli, Marco
    Liao, Hsiang-I
    Olson, C. Anders
    Chen, Po-Chiang
    Zhang, Rui
    Roberts, Richard W.
    Sun, Ren
    Cote, Richard J.
    Thompson, Mark E.
    Zhou, Chongwu
    [J]. ACS NANO, 2009, 3 (05) : 1219 - 1224
  • [14] A Microarray Immunoassay for Serum Thyrotropin and Thyroglobulin Using Antibodies Immobilized on Track-Etched Membranes
    Jain B.
    Kumarasamy J.
    Gholve C.
    Kulkarni S.
    Rajan M.G.R.
    [J]. Indian Journal of Clinical Biochemistry, 2017, 32 (2) : 193 - 199
  • [15] THE CHARGE CHARACTERIZATION OF NATIVE AND DEGLYCOSYLATED THYROTROPIN
    KEEL, BA
    HARMS, RL
    AMIR, SM
    [J]. ENDOCRINE RESEARCH, 1990, 16 (02) : 151 - 163
  • [16] Silicon nanowire biosensors for detection of cardiac troponin I (cTnI) with high sensitivity
    Kim, Kihyun
    Park, Chanoh
    Kwon, Donghoon
    Kim, Donghoon
    Meyyappan, M.
    Jeon, Sangmin
    Lee, Jeong-Soo
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 77 : 695 - 701
  • [17] Silicon nanowires as enhancement-mode Schottky barrier field-effect transistors
    Koo, SM
    Edelstein, MD
    Li, QL
    Richter, CA
    Vogel, EM
    [J]. NANOTECHNOLOGY, 2005, 16 (09) : 1482 - 1485
  • [18] CLEAVAGE OF STRUCTURAL PROTEINS DURING ASSEMBLY OF HEAD OF BACTERIOPHAGE-T4
    LAEMMLI, UK
    [J]. NATURE, 1970, 227 (5259) : 680 - +
  • [19] CONGENITAL HYPOTHYROIDISM - A NEWBORN SCREENING SUCCESS STORY
    LAFRANCHI, S
    [J]. ENDOCRINOLOGIST, 1994, 4 (06) : 477 - 486
  • [20] Simultaneous detection of MCF-7 and HepG2 cells in blood by ICP-MS with gold nanoparticles and quantum dots as elemental tags
    Li, Xiaoting
    Chen, Beibei
    He, Man
    Wang, Han
    Xiao, Guangyang
    Yang, Bin
    Hu, Bin
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 90 : 343 - 348