Introduction of a New Parameter for Evaluation of Digital Radiography System Performance

被引:1
|
作者
Choopani, Mohammad Reza [1 ]
Chaparian, Ali [2 ]
机构
[1] Isfahan Univ Med Sci, Fac Paramed, Student Res Comm, Esfahan, Iran
[2] Isfahan Univ Med Sci, Technol Radiol Dept, Esfahan, Iran
来源
JOURNAL OF MEDICAL SIGNALS & SENSORS | 2020年 / 10卷 / 03期
关键词
Contrast detail; contrast-detail radiography phantom; digital radiography; image quality; radiation dose; IMAGE QUALITY; COMPUTED RADIOGRAPHY; DETECTOR;
D O I
10.4103/jmss.JMSS_53_19
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The aim of this study was to compare the image quality and radiation doses in various digital radiography systems using contrast-detail radiography (CDRAD) phantom. Methods: The image quality and radiation dose for seven different digital radiography systems were compared using the CDRAD phantom. Incident air kerma (IAK) values were measured for certain exposure settings in all digital radiography systems. The images from the CDRAD phantom were evaluated by three observers. The results were displayed in the form of a contrast-detail (CD) curve. In addition, the inverse image quality figure (IQFinv)-to-IAK ratios were used for quantitative comparison of different digital radiography system performance. Results: Results of this study showed that the CD curves cannot be suitable criterion for determining the performance of digital radiography systems. For this reason, IQFinv-to-radiation dose (IAK) ratios in a fixed radiation condition were used. The highest performance in terms of producing high-quality images and low radiation dose was related to X-ray unit 1 and the lowest performance was for X-ray unit 5. Conclusion: The ratio of IQFinv to IAK for performance evaluation of digital radiography systems is an innovation of this study. A digital radiography system with a higher IQFinv-to-IAK ratio is associated with lower patient dose and better image quality. Therefore, it is recommended to equip the new imaging centers with the systems that have higher IQFinv-to-IAK ratios.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [21] Imaging performance evaluation of a desktop computed radiography system
    Fetterly, KA
    Hangiandreou, NJ
    RADIOLOGY, 1999, 213P : 235 - 235
  • [22] New computed radiography technologies in digital radiography
    Fasbender, R
    Schaetzing, R
    RADIOLOGE, 2003, 43 (05): : 367 - 373
  • [23] The use of digital radiography in the evaluation of radioactive materials packaging performance testing
    May, Cecil G.
    Gelder, Lawrence F.
    Howard, Boyd D.
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2007, VOL 7: OPERATIONS, APPLICATIONS AND COMPONENTS, 2007, 7 : 509 - 519
  • [24] Evaluation of the performance of digital x-ray systems in pelvis radiography
    Jreije, Antonio
    Krynke, Leonid
    Griciene, Birute
    Rimkus, Bernardas
    Dementaviciene, Jurate
    Skovorodko, Kirill
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (03)
  • [25] DIGITAL IMAGE EVALUATION METHOD FOR DIGITAL RADIOGRAPHY
    Mori, Masako
    Kashiwa, Toshibumi
    Aoki, Yoshimitsu
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2010, VOL 5, 2010, : 207 - 213
  • [26] DIGITAL IMAGE EVALUATION METHOD FOR DIGITAL RADIOGRAPHY
    Mori, Masako
    Kashiwa, Toshibumi
    Aoki, Yoshimitsu
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 1, 2011, : 223 - +
  • [27] Development of Digital Radiography System
    Yamazaki, T
    Morishita, M
    Kaifu, N
    Endo, Y
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 536 - 541
  • [28] Evaluation of simulated external root resorptions with digital radiography and digital subtraction radiography
    Ono, Evelise
    Medici Filho, Edmundo
    Leite, Horacio Faig
    Oshiro Tanaka, Jefferson Luis
    Leonelli De Moraes, Mari Eli
    De Melo Castilho, Julio Cezar
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (03) : 324 - 333
  • [29] New IQI for digital radiography
    Mori, Masako
    Kashiwa, Toshibumi
    Aoki, Yoshimitsu
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2007, VOL 1: CODES AND STANDARDS, 2007, 1 : 453 - 456
  • [30] PERFORMANCE-TEST AND QUALITY-CONTROL OF A DIGITAL RADIOGRAPHY SYSTEM
    SHAW, CG
    BASSANO, DA
    CHAMBERLAIN, CC
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 347 : 130 - 140