Aptamer selection by direct microfluidic recovery and surface plasmon resonance evaluation

被引:25
作者
Dausse, Eric [1 ,2 ]
Barre, Aurelien [3 ]
Aime, Ahissan [1 ,2 ]
Groppi, Alexis [3 ]
Rico, Alain [4 ]
Ainali, Chrysanthi [4 ]
Salgado, Gilmar [1 ,2 ]
Palau, William [1 ,2 ]
Daguerre, Emilie [5 ]
Nikolski, Macha [3 ]
Toulme, Jean-Jacques [1 ,2 ]
Di Primo, Carmelo [1 ,2 ]
机构
[1] Univ Bordeaux, Lab ARNA, F-33000 Bordeaux, France
[2] CNRS, UMR 5320, INSERM, U1212,IECB, F-33600 Pessac, France
[3] Univ Bordeaux, CBiB, LaBRI, F-33000 Bordeaux, France
[4] Thermo Fisher Sci, F-91190 St Aubin, France
[5] Novaptech, F-33000 Bordeaux, France
关键词
Microfluidic recovery; SELEX; Aptamers; RNA; Surface plasmon resonance; Kinetics; IN-VITRO SELECTION; DNA-APTAMERS; RNA APTAMERS; SYSTEMATIC EVOLUTION; EXPONENTIAL ENRICHMENT; LOOP INTERACTIONS; SELEX SELECTION; MESSENGER-RNA; AFFINITY; PROTEIN;
D O I
10.1016/j.bios.2016.02.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A surface plasmon resonance (SPR)-based SELEX approach has been used to raise RNA aptamers against a structured RNA, derived from XBP1 pre-mRNA, that folds as two contiguous hairpins. Thanks to the design of the internal microfluidic cartridge of the instrument, the selection was performed during the dissociation phase of the SPR analysis by recovering the aptamer candidates directly from the target immobilized onto the sensor chip surface. The evaluation of the pools was performed by SPR, simultaneously, during the association phase, each time the amplified and transcribed candidates were injected over the immobilized target. SPR coupled with SELEX from the first to the last round allowed identifying RNA aptamers that formed highly stable loop-loop complexes (K-D equal to 8 nM) with the hairpin located on the 5' side of the target. High throughput sequencing of two key rounds confirmed the evolution observed by SPR and also revealed the selection of hairpins displaying a loop not fully complementary to the loop of its target. These candidates were selected mainly because they bound 79 times faster to the target than those having a complementary loop. SELEX coupled with SPR is expected to speed up the selection process because selection and evaluation are performed simultaneously. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 52 条
[1]   A Sol-Gel-Based Microfluidics System Enhances the Efficiency of RNA Aptamer Selection [J].
Ahn, Ji-Young ;
Jo, Minjoung ;
Dua, Pooja ;
Lee, Dong-ki ;
Kim, Soyoun .
OLIGONUCLEOTIDES, 2011, 21 (02) :93-100
[2]   Apical loop-internal loop interactions:: A new RNA-RNA recognition motif identified through in vitro selection against RNA hairpins of the hepatitis C virus mRNA [J].
Aldaz-Carroll, L ;
Tallet, A ;
Dausse, E ;
Yurchenko, L ;
Toulmé, JJ .
BIOCHEMISTRY, 2002, 41 (18) :5883-5893
[3]   Isolation and Optimization of Murine IL-10 Receptor Blocking Oligonucleotide Aptamers Using High-throughput Sequencing [J].
Berezhnoy, Alexey ;
Stewart, C. Andrew ;
Mcnamara, James O., II ;
Thiel, William ;
Giangrande, Paloma ;
Trinchieri, Giorgio ;
Gilboa, Eli .
MOLECULAR THERAPY, 2012, 20 (06) :1242-1250
[4]   Non-SELEX selection of aptamers [J].
Berezovski, M ;
Musheev, M ;
Drabovich, A ;
Krylov, SN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (05) :1410-1411
[5]   DNA aptamers selected against the HIV-1 trans-activation-responsive RNA element form RNA-DNA kissing complexes [J].
Boiziau, C ;
Dausse, E ;
Yurchenko, L ;
Toulmé, JJ .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (18) :12730-12737
[6]   Quantitative selection of DNA aptamers through microfluidic selection and high-throughput sequencing [J].
Cho, Minseon ;
Xiao, Yi ;
Nie, Jeff ;
Stewart, Ron ;
Csordas, Andrew T. ;
Oh, Seung Soo ;
Thomson, James A. ;
Soh, H. Tom .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (35) :15373-15378
[7]  
Dausse Eric, 2005, V288, P391
[8]   HAPIscreen, a method for high-throughput aptamer identification [J].
Dausse, Eric ;
Taouji, Said ;
Evade, Laetitia ;
Di Primo, Carmelo ;
Chevet, Eric ;
Toulme, Jean-Jacques .
JOURNAL OF NANOBIOTECHNOLOGY, 2011, 9
[9]   Real time analysis of the RNAI-RNAII-Rop complex by surface plasmon resonance: from a decaying surface to a standard kinetic analysis [J].
Di Primo, Carmelo .
JOURNAL OF MOLECULAR RECOGNITION, 2008, 21 (01) :37-45
[10]   Determination of refractive index increment ratios for protein-nucleic acid complexes by surface plasmon resonance [J].
Di Primo, Carmelo ;
Lebars, Isabelle .
ANALYTICAL BIOCHEMISTRY, 2007, 368 (02) :148-155