Lateral Force Calibration: Accurate Procedures for Colloidal Probe Friction Measurements in Atomic Force Microscopy

被引:23
作者
Chung, Koo-Hyun [1 ]
Pratt, Jon R. [1 ]
Reitsma, Mark G. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
SPRING CONSTANT; CANTILEVERS; ADHESION; FILMS; SHEAR; AFM;
D O I
10.1021/la902488r
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The colloidal probe technique for atomic force microscopy (AFM) has allowed the investigation of ail extensive range of surface force phenomena, including the measurement of frictional (lateral) forces between numerous materials. The quantitative accuracy of such friction measurements is often debated, in part due to a lack of confidence in existing calibration strategies. Here we compare three in situ AFM lateral force calibration techniques using it single colloidal probe, seeking to establish a foundation for quantitative measurement by linking these techniques to accurate force references available at the National Institute of Standards and Technology. We introduce a procedure for calibrating the AFM lateral force response to known electrostatic forces applied directly to the conductive colloidal probe. In it second procedure, we apply known force directly to the colloidal probe using a precalibrated piezo-resistive reference cantilever. We found agreement between these direct methods oil the order of 2% (within random uncertainty for both Measurements). In a third procedure, we performed it displacement-based calibration using the piezo-resistive reference cantilever its a stiffness reference artifact. The method demonstrated agreement on the order of 7% with the direct force methods, with the difference attributed to ail expected. systematic uncertainty, caused by in-plane deflection in the cantilever during loading. The comparison establishes the existing limits of instrument accuracy and sets down a basis for selection criteria for materials and methods in colloidal probe friction (lateral) force measurements via atomic force microscopy.
引用
收藏
页码:1386 / 1394
页数:9
相关论文
共 38 条
[1]   Lubricating properties of the initial salivary pellicle - an AFM Study [J].
Berg, ICH ;
Rutland, MW ;
Arnebrant, T .
BIOFOULING, 2003, 19 (06) :365-369
[2]   Comparison of calibration methods for atomic-force microscopy cantilevers [J].
Burnham, NA ;
Chen, X ;
Hodges, CS ;
Matei, GA ;
Thoreson, EJ ;
Roberts, CJ ;
Davies, MC ;
Tendler, SJB .
NANOTECHNOLOGY, 2003, 14 (01) :1-6
[3]   Force measurements with the atomic force microscope: Technique, interpretation and applications [J].
Butt, HJ ;
Cappella, B ;
Kappl, M .
SURFACE SCIENCE REPORTS, 2005, 59 (1-6) :1-152
[4]   Force calibration in lateral force microscopy [J].
Cain, RG ;
Biggs, S ;
Page, NW .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 227 (01) :55-65
[5]   Microscopic and macroscopic effects of surface lubricant films in granular shear [J].
Cain, RG ;
Page, NW ;
Biggs, S .
PHYSICAL REVIEW E, 2000, 62 (06) :8369-8379
[6]   Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization [J].
Cannara, Rachel J. ;
Eglin, Michael ;
Carpick, Robert W. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (05)
[7]   Interactions of hydroxyapatite surfaces:: Conditioning films of human whole saliva [J].
Cardenas, Marite ;
Valle-Delgado, Juan Jose ;
Hamit, Jildiz ;
Rutland, Mark W. ;
Arnebrant, Thomas .
LANGMUIR, 2008, 24 (14) :7262-7268
[8]   Lateral stiffness: A new nanomechanical measurement for the determination of shear strengths with friction force microscopy [J].
Carpick, RW ;
Ogletree, DF ;
Salmeron, M .
APPLIED PHYSICS LETTERS, 1997, 70 (12) :1548-1550
[9]   Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy [J].
Chung, Koo-Hyun ;
Shaw, Gordon A. ;
Pratt, Jon R. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (06)
[10]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405