Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty

被引:162
作者
Mont, Michael A. [1 ]
Seyler, Thorsten M. [1 ]
Ragland, Phillip S. [1 ]
Starr, Roland [1 ]
Erhart, Jochen [1 ]
Bhave, Anil [1 ]
机构
[1] Sinai Hosp, Ctr Joint Preservat & Reconstruct, Rubin Inst Adv Orthoped, Baltimore, MD 21215 USA
关键词
gait analysis; resurfacing; total hip arthroplasty; metal-on-metal;
D O I
10.1016/j.arth.2006.03.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients with standard total hip arthroplasties may have reduced hip abduction and extension moments when compared with normal nonostcoarthritic hips. In comparison, patients after resurfacing total hip arthroplasty appear to have a near-normal gait. The authors evaluated temporal-spatial parameters, hip kinematics, and kinetics in hip resurfacing patients compared with patients with unilateral osteoarthritic hips and unilateral standard total hip arthroplasties. Patients with resurfacing walked faster (average 1.26 m/s) and were comparable with normals. There were no significant differences in hip abductor and extensor moments of patients with resurfacing compared with patients in the standard hip arthroplasty group. This study showed more normal hip kinematics and functionality in resurfacing hip arthroplasty, which may be due to the large femoral head. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:100 / 108
页数:9
相关论文
共 38 条
[21]   Comparison of offset in Birmingham hip resurfacing and hybrid total hip arthroplasty [J].
Loughead, JM ;
Chesney, D ;
Holland, JP ;
McCaskie, AW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :163-166
[22]   Vertical ground reaction forces: objective measures of gait following hip arthroplasty [J].
McCrory, JL ;
White, SC ;
Lifeso, RM .
GAIT & POSTURE, 2001, 14 (02) :104-109
[23]   FRICTION AND WEAR PROPERTIES OF POLYMER, METAL, AND CERAMIC PROSTHETIC JOINT MATERIALS EVALUATED ON A MULTICHANNEL SCREENING DEVICE [J].
MCKELLOP, H ;
CLARKE, I ;
MARKOLF, K ;
AMSTUTZ, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (05) :619-653
[24]  
MESKO JW, 1994, CLIN ORTHOP RELAT R, P168
[25]  
MULLER ME, 1995, CLIN ORTHOP RELAT R, P54
[26]   Locomotor deficits before and two months after knee arthroplasty [J].
Ouellet, D ;
Moffet, H .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2002, 47 (05) :484-493
[27]  
PERRIN T, 1985, CLIN ORTHOP RELAT R, P252
[28]   Three-dimensional gait analysis in women with a total hip arthroplasty [J].
Perron, M ;
Malouin, F ;
Moffet, H ;
McFadyen, BJ .
CLINICAL BIOMECHANICS, 2000, 15 (07) :504-515
[29]   The effect of anatomical positional relationships on kinetic parameters after total hip replacement [J].
Rösler, J ;
Perka, C .
INTERNATIONAL ORTHOPAEDICS, 2000, 24 (01) :23-27
[30]   Long duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces [J].
Schmalzried, TP ;
Peters, PC ;
Maurer, BT ;
Bragdon, CR ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1996, 11 (03) :322-331