Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography

被引:42
作者
Golparvar, M [1 ]
Naddafnia, H [1 ]
Saghaei, M [1 ]
机构
[1] Isfahan Univ Med Sci, Dept Anesthesia & Crit Care, Esfahan, Iran
关键词
D O I
10.1097/00000539-200212000-00040
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The finger plethysmographic waveform of pulse oximeters is a qualitative indicator of fingertip perfusion. This waveform has been used to assess the depth of anesthesia. Its cyclical changes associated with mechanical ventilation have also been used to detect changes in blood volume under normotensive conditions and has revealed that minimal normotensive hypovolemia can cause a significant increase in the delta-down component of this waveform. Hypovolemia may be associated with hypotension; the latter may be due to causes other than hypovolemia. Because the effects of the hypotension on plethysmographic waveform have not been evaluated, it may be difficult to detect hypovolemia in these conditions by inspecting a plethysmogram. Therefore, we performed this study to evaluate the effect of normovolemic hypotension on characteristics of plethysmographic waveform in 33 adult patients undergoing general anesthesia with controlled hypotension. The delta-down and ventilatory systolic variation components were increased significantly with decreases in systolic blood pressure. The result of this study shows that the effect of pharmacologic hypotension on the plethysmographic waveform of pulse oximeter is similar to that of minimal hypovolemia. Therefore, blood volume may be inaccurately assessed by the inspection of ventilatory-induced cyclical changes of pulse oximetric waveform in the presence of hypotension.
引用
收藏
页码:1686 / 1690
页数:5
相关论文
共 12 条
[1]  
CORIAT P, 1994, ANESTH ANALG, V78, P46
[2]  
MATTILA M, 1996, UTILIZING PULSE OXIM
[3]   The peripheral pulse wave: Information overlooked [J].
Murray, WB ;
Foster, PA .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (05) :365-377
[4]   SYSTOLIC BLOOD-PRESSURE VARIATION IS A SENSITIVE INDICATOR OF HYPOVOLEMIA IN VENTILATED DOGS SUBJECTED TO GRADED HEMORRHAGE [J].
PEREL, A ;
PIZOV, R ;
COTEV, S .
ANESTHESIOLOGY, 1987, 67 (04) :498-502
[5]  
PIZOV R, 1988, ANESTH ANALG, V67, P170
[6]  
Pizov R, 1990, J Clin Anesth, V2, P96, DOI 10.1016/0952-8180(90)90061-7
[7]   THE EFFECT OF GRADED HEMORRHAGE AND INTRAVASCULAR VOLUME REPLACEMENT ON SYSTOLIC PRESSURE VARIATION IN HUMANS DURING MECHANICAL AND SPONTANEOUS VENTILATION [J].
ROOKE, GA ;
SCHWID, HA ;
SHAPIRA, Y .
ANESTHESIA AND ANALGESIA, 1995, 80 (05) :925-932
[8]   STUDIES ON ACUTE CARDIOVASCULAR EFFECTS OF INTRAVENOUS SODIUM NITROPRUSSIDE [J].
SCHLANT, RC ;
TSAGARIS, TS ;
ROBERTSON, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1962, 9 (01) :51-+
[9]   Pulse oximetry plethysmographic waveform during changes in blood volume [J].
Shamir, M ;
Eidelman, LA ;
Floman, Y ;
Kaplan, L ;
Pizov, R .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (02) :178-181
[10]   Arterial pulse oximetry loops: A new method of monitoring vascular tone [J].
Shelley, KH ;
Murray, WB ;
Chang, D .
JOURNAL OF CLINICAL MONITORING, 1997, 13 (04) :223-228