High Detection Rate of Atrial Fibrillation With Insertable Cardiac Monitor Implantation in Patients With Cryptogenic Stroke Diagnosed by Magnetic Resonance Imaging

被引:19
作者
Iwata, Tomonori [1 ]
Todo, Kenichi [2 ]
Yamagami, Hiroshi [3 ]
Morimoto, Masafumi [4 ]
Hashimoto, Tetsuya [5 ]
Doijiri, Ryosuke [6 ]
Furuya, Hiroyuki [7 ]
机构
[1] Tokai Univ, Dept Neurol, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
[2] Osaka Univ, Dept Neurol, Suita, Osaka, Japan
[3] Natl Cardiovasc & Cerebral Ctr, Dept Neurol, Suita, Osaka, Japan
[4] Yokohama Shintoshi Neurosurg Hosp, Dept Neurosurg, Yokohama, Kanagawa, Japan
[5] Saiseikai Fukuoka Gen Hosp, Dept Neurol, Fukuoka, Fukuoka, Japan
[6] Iwate Prefectural Cent Hosp, Dept Neurol, Morioka, Iwate, Japan
[7] Tokai Univ, Basic Clin Sci & Publ Hlth, Sch Med, Isehara, Kanagawa, Japan
关键词
Insertable cardiac monitor; atrial fibrillation; embolic stroke of undetermined source; cryptogenic stroke; UNDETERMINED SOURCE; EMBOLIC STROKE; POPULATION; PREVENTION;
D O I
10.1016/j.jstrokecerebrovasdis.2019.05.023
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Detection and treatment of atrial fibrillation (AF) is a major goal in preventing secondary stroke. Insertable cardiac monitors (ICMs) are available for diagnosis of arrhythmia monitoring in patients with cryptogenic stroke. Magnetic resonance imaging (MRI)-based diagnostic evaluation for acute ischemic stroke subtype classification is common in Japan and can be useful for specific diagnosis of cryptogenic stroke. Purpose: We aimed to investigate the detection rate of AF with an ICM in patients with cryptogenic stroke who were diagnosed by MRI. Methods: We performed a retrospective, multicenter, observational study. AF monitoring data of an ICM (Reveal LINQ) in patients with cryptogenic stroke were registered from 5 stroke centers in Japan between October 2016 and March 2018. ICM candidates in cryptogenic stroke were diagnosed by MRI-based evaluation and selected according to the criteria proposed by the Japan Stroke Society. Detection of AF was defined as AF for longer than 120 seconds. Results: Eighty-four consecutive patients (64 men; aged 38-90 years) underwent ICM implantation after diagnosis of cryptogenic stroke. AF was detected in 22 of 84 (26.2%) patients with an ICM during a median follow-up of 221.5 days (range: 93-365 days). The detection rate of AF within 3 months after ICM implantation was 21.4%. Conclusions: The AF detection rate with an ICM is approximately one fifth within 3 months in patients with cryptogenic stroke as diagnosed by MRI. Our data suggest that the Japanese criteria based on MRI may be useful for selecting adequate candidates for ICM implantation.
引用
收藏
页码:2569 / 2573
页数:5
相关论文
共 22 条
[1]   Current status of clinical background of patients with atrial fibrillation in a community-based survey: The Fushimi AF Registry [J].
Akao, Masaharu ;
Chun, Yeong-Hwa ;
Wada, Hiromichi ;
Esato, Masahiro ;
Hashimoto, Tetsuo ;
Abe, Mitsuru ;
Hasegawa, Koji ;
Tsuji, Hikari ;
Furuke, Keizo .
JOURNAL OF CARDIOLOGY, 2013, 61 (3-4) :260-266
[2]   Association of Atrial Fibrillation With Cognitive Decline and Dementia Over 20 Years: The ARIC-NCS (Atherosclerosis Risk in Communities Neurocognitive Study) [J].
Chen, Lin Y. ;
Norby, Faye L. ;
Gottesman, Rebecca F. ;
Mosley, Thomas H. ;
Soliman, Elsayed Z. ;
Agarwal, Sunil K. ;
Loehr, Laura R. ;
Folsom, Aaron R. ;
Coresh, Josef ;
Alonso, Alvaro .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (06)
[3]   Cost-effectiveness of an insertable cardiac monitor to detect atrial fibrillation in patients with cryptogenic stroke [J].
Diamantopoulos, Alex ;
Sawyer, Laura M. ;
Lip, Gregory Y. H. ;
Witte, Klaus K. ;
Reynolds, Matthew R. ;
Fauchier, Laurent ;
Thijs, Vincent ;
Brown, Ben ;
Angulo, Maria E. Quiroz ;
Diener, Hans-Christoph .
INTERNATIONAL JOURNAL OF STROKE, 2016, 11 (03) :302-312
[4]   Design of Randomized, double-blind, Evaluation in secondary Stroke Prevention comparing the EfficaCy and safety of the oral Thrombin inhibitor dabigatran etexilate vs. acetylsalicylic acid in patients with Embolic Stroke of Undetermined Source (RE-SPECT ESUS) [J].
Diener, Hans-Christoph ;
Easton, J. Donald ;
Granger, Christopher B. ;
Cronin, Lisa ;
Duffy, Christine ;
Cotton, Daniel ;
Brueckmann, Martina ;
Sacco, Ralph L. .
INTERNATIONAL JOURNAL OF STROKE, 2015, 10 (08) :1309-1312
[5]   N-terminal pro-brain natriuretic peptide shows diagnostic accuracy for detecting atrial fibrillation in cryptogenic stroke patients [J].
Fonseca, Ana Catarina ;
Brito, Dulce ;
Pinho e Melo, Teresa ;
Geraldes, Ruth ;
Canhao, Patricia ;
Caplan, Louis R. ;
Ferro, Jose M. .
INTERNATIONAL JOURNAL OF STROKE, 2014, 9 (04) :419-425
[6]   Atrial fibrillation in the elderly [J].
Franken, Roberto A. ;
Rosa, Ronaldo F. ;
Santos, Silvio C. M. .
JOURNAL OF GERIATRIC CARDIOLOGY, 2012, 9 (02) :91-100
[7]   Apixaban for treatment of embolic stroke of undetermined source (ATTICUS randomized trial): Rationale and study design [J].
Geisler, Tobias ;
Poli, Sven ;
Meisner, Christoph ;
Schreieck, Juergen ;
Zuern, Christine S. ;
Naegele, Thomas ;
Brachmann, Johannes ;
Jung, Werner ;
Gahn, Georg ;
Schmid, Elisabeth ;
Baeezner, Hansjoerg ;
Keller, Timea ;
Petzold, Gabor C. ;
Schrickel, Jan-Wilko ;
Liman, Jan ;
Wachter, Rolf ;
Schoen, Frauke ;
Schabet, Martin ;
Lindner, Alfred ;
Ludolph, Albert C. ;
Kimmig, Hubert ;
Jander, Sebastian ;
Schlegel, Uwe ;
Gawaz, Meinrad ;
Ziemann, Ulf .
INTERNATIONAL JOURNAL OF STROKE, 2017, 12 (09) :985-990
[8]   Rivaroxaban for Stroke Prevention after Embolic Stroke of Undetermined Source [J].
Hart, R. G. ;
Sharma, M. ;
Mundl, H. ;
Kasner, S. E. ;
Bangdiwala, S. I. ;
Berkowitz, S. D. ;
Swaminathan, B. ;
Lavados, P. ;
Wang, Y. ;
Wang, Y. ;
Davalos, A. ;
Shamalov, N. ;
Mikulik, R. ;
Cunha, L. ;
Lindgren, A. ;
Arauz, A. ;
Lang, W. ;
Czlonkowska, A. ;
Eckstein, J. ;
Gagliardi, R. J. ;
Amarenco, P. ;
Ameriso, S. F. ;
Tatlisumak, T. ;
Veltkamp, R. ;
Hankey, G. J. ;
Toni, D. ;
Bereczki, D. ;
Uchiyama, S. ;
Ntaios, G. ;
Yoon, B. -W. ;
Brouns, R. ;
Endres, M. ;
Muir, K. W. ;
Bornstein, N. ;
Ozturk, S. ;
O'Donnell, M. J. ;
Basson, M. M. De Vries ;
Pare, G. ;
Pater, C. ;
Kirsch, B. ;
Sheridan, P. ;
Peters, G. ;
Weitz, J. I. ;
Peacock, W. F. ;
Shoamanesh, A. ;
Benavente, O. R. ;
Joyner, C. ;
Themeles, E. ;
Connolly, S. J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (23) :2191-2201
[9]   Embolic Stroke of Undetermined Source A Systematic Review and Clinical Update [J].
Hart, Robert G. ;
Catanese, Luciana ;
Perera, Kanjana S. ;
Ntaios, George ;
Connolly, Stuart J. .
STROKE, 2017, 48 (04) :867-872
[10]   Embolic strokes of undetermined source: the case for a new clinical construct [J].
Hart, Robert G. ;
Diener, Hans-Christoph ;
Coutts, Shelagh B. ;
Easton, J. Donald ;
Granger, Christopher B. ;
O'Donnell, Martini J. ;
Sacco, Ralph L. ;
Connolly, Stuart J. .
LANCET NEUROLOGY, 2014, 13 (04) :429-438