A blinded assessment of video quality in wearable technology for telementoring in open surgery: the Google Glass experience

被引:39
作者
Hashimoto, Daniel A. [1 ]
Phitayakorn, Roy [1 ]
Fernandez-del Castillo, Carlos [1 ]
Meireles, Ozanan [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Surg, 55 Fruit St,GRB425, Boston, MA 02114 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2016年 / 30卷 / 01期
关键词
Telementoring; Surgical education; Wearable technology; Open surgery;
D O I
10.1007/s00464-015-4178-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The goal of telementoring is to recreate face-to-face encounters with a digital presence. Open-surgery telementoring is limited by lack of surgeon's point-of-view cameras. Google Glass is a wearable computer that looks like a pair of glasses but is equipped with wireless connectivity, a camera, and viewing screen for video conferencing. This study aimed to assess the safety of using Google Glass by assessing the video quality of a telementoring session. Methods Thirty-four (n = 34) surgeons at a single institution were surveyed and blindly compared via video captured with Google Glass versus an Apple iPhone 5 during the open cholecystectomy portion of a Whipple. Surgeons were asked to evaluate the quality of the video and its adequacy for safe use in telementoring. Results Thirty-four of 107 invited surgical attendings (32 %) responded to the anonymous survey. A total of 50 % rated the Google Glass video as fair with the other 50 % rating it as bad to poor. A total of 52.9 % of respondents rated the Apple iPhone video as good. A significantly greater proportion of respondents felt Google Glass video quality was inadequate for telementoring versus the Apple iPhone's (82.4 vs 26.5 %, p < 0.0001). Intraclass correlation coefficient was 0.924 (95 % CI 0.660-0.999, p < 0.001). Conclusion While Google Glass provides a great breadth of functionality as a wearable device with two-way communication capabilities, current hardware limitations prevent its use as a telementoring device in surgery as the video quality is inadequate for safe telementoring. As the device is still in initial phases of development, future iterations or competitor devices may provide a better telementoring application for wearable devices.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 21 条
  • [1] [Anonymous], 2003, Final report from the video quality experts group on the validation of objective models of video quality assessment
  • [2] A comprehensive review of telementoring applications in laparoscopic general surgery
    Antoniou, Stavros A.
    Antoniou, George A.
    Franzen, Jan
    Bollmann, Stefan
    Koch, Oliver O.
    Pointner, Rudolf
    Granderath, Frank A.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (08): : 2111 - 2116
  • [3] Telesurgery: Remote knowledge translation in clinical surgery
    Anvari, Mehran
    [J]. WORLD JOURNAL OF SURGERY, 2007, 31 (08) : 1545 - 1550
  • [4] Telementoring and telerobotics in urological surgery
    Challacombe B.
    Wheatstone S.
    [J]. Current Urology Reports, 2010, 11 (1) : 22 - 28
  • [5] CHANG JM, 2013, ABC NEWS
  • [6] Remote evaluation of laparoscopic performance using the global operative assessment of laparoscopic skills
    Choy, Ian
    Fecso, Andras
    Kwong, Josephine
    Jackson, Tim
    Okrainec, Allan
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (02): : 378 - 383
  • [7] Crawford Innes, 2011, J Emerg Trauma Shock, V4, P526, DOI 10.4103/0974-2700.86654
  • [8] Long distance telementoring - A novel tool for laparoscopy aboard the USS Abraham Lincoln
    Cubano, M
    Poulose, BK
    Talamini, MA
    Stewart, R
    Antosek, LE
    Lentz, R
    Nibe, R
    Kutka, MF
    Mendoza-Sagaon, M
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (07): : 673 - 678
  • [9] Engelen L, 2013, IS GOOGLE GLASS USEF
  • [10] Preferred position of visual displays relative to the eyes: a field study of visual strain and individual differences
    Jaschinski, W
    Heuer, H
    Kylian, H
    [J]. ERGONOMICS, 1998, 41 (07) : 1034 - 1049