Clinical Results of the Wear Performance of Cross-Linked Polyethylene in Total Hip Arthroplasty Prospective Randomized Trial

被引:22
作者
Ise, Kentaro [1 ]
Kawanabe, Keiichi [1 ]
Tamura, Jiro [1 ]
Akiyama, Haruhiko [1 ]
Goto, Koji [1 ]
Nakamura, Takashi [1 ]
机构
[1] Kyoto Univ, Dept Orthoped Surg, Sakyo Ku, Kyoto 6068507, Japan
关键词
wear; cross-linked polyethylene; total hip arthroplasty; clinical result; prospective randomized trial; FOLLOW-UP; FEMORAL-HEAD; TOTAL JOINT; PENETRATION; OSTEOLYSIS; ALUMINA; SURFACE;
D O I
10.1016/j.arth.2009.05.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To investigate the clinical results of cross-linked polyethylene (CLPE) and to compare the CLPE wear against zirconia and stainless steel heads, we studied the radiographic wear after a minimum 3-year follow-up in total hip arthroplasty (THA). Ninety-four hips were randomly implanted with a 22.225-mm head cemented THA-the group of non-CLPE against zirconia and CLPE against 2 different zirconias and stainless steel. The linear wear rate was significantly lower in the group of CLPE against zirconia (0.067, 0.059 mm/y) and against stainless steel (0.068 mm/y) compared with non-CLPE against zirconia (0.170 mm/y). in the short-term results, the wear performance of CLPE against zirconia was superior to that of non-CLPE; however, it did not show a better wear rate than CLPE against stainless steel. Furthermore, long-term investigations will be necessary for understanding CLPE wear in vivo.
引用
收藏
页码:1216 / 1220
页数:5
相关论文
共 50 条
[41]   Intermediate Results of Simultaneous Alumina-on-Alumina Bearing and Alumina-on-Highly Cross-Linked Polyethylene Bearing Total Hip Arthroplasties [J].
Kim, Young-Hoo ;
Kim, Jun-Shik ;
Choi, Yoo-Wang ;
Kwon, Oh-Ryong .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :885-891
[42]   Highly cross-linked polyethylene is the new 'gold standard' bearing material for total hip arthroplasty [J].
Medley, John B. .
BIOSURFACE AND BIOTRIBOLOGY, 2021, 7 (02) :53-59
[43]   A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty [J].
Mu, Zongyou ;
Tian, Jialiang ;
Wu, Taixiang ;
Yang, Jing ;
Pei, Fuxing .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :599-604
[44]   Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study [J].
Tsukamoto, Manabu ;
Ohnishi, Hideo ;
Mori, Toshiharu ;
Kawasaki, Makoto ;
Uchida, Soshi ;
Sakai, Akinori .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :161-+
[45]   Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial [J].
Salemyr, Mats ;
Muren, Olle ;
Ahl, Torbjorn ;
Boden, Henrik ;
Chammout, Ghazi ;
Stark, Andre ;
Skoldenberg, Olof .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (08) :1499-1505
[46]   Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial [J].
Mats Salemyr ;
Olle Muren ;
Torbjörn Ahl ;
Henrik Bodén ;
Ghazi Chammout ;
André Stark ;
Olof Sköldenberg .
International Orthopaedics, 2015, 39 :1499-1505
[47]   Large Femoral Heads in Total Hip Arthroplasty With Vitamin E Highly Cross-Linked Polyethylene: Head Penetration Rates Compared to Highly Cross-Linked Polyethylene [J].
Nielson, Trent ;
Owens, Garrett ;
Miller, Brandon ;
Meneghini, Ethan ;
Deckard, Evan R. ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2022, 37 (07) :S685-S691
[48]   In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty [J].
Nishimura, Manase ;
Nakamura, Takuya ;
Nishida, Hideji ;
Misaki, Tomonori ;
Aikawa, Takao .
JOURNAL OF ARTHROPLASTY, 2024, 39 (12) :3092-3096
[49]   Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report [J].
Li, Chenkai ;
Zhang, Haining .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[50]   Early failure for wear after ceramic-on-highly cross-linked polyethylene total hip arthroplasty: a case report [J].
Chenkai Li ;
Haining Zhang .
BMC Musculoskeletal Disorders, 21