Clinical Results of the Wear Performance of Cross-Linked Polyethylene in Total Hip Arthroplasty Prospective Randomized Trial

被引:22
作者
Ise, Kentaro [1 ]
Kawanabe, Keiichi [1 ]
Tamura, Jiro [1 ]
Akiyama, Haruhiko [1 ]
Goto, Koji [1 ]
Nakamura, Takashi [1 ]
机构
[1] Kyoto Univ, Dept Orthoped Surg, Sakyo Ku, Kyoto 6068507, Japan
关键词
wear; cross-linked polyethylene; total hip arthroplasty; clinical result; prospective randomized trial; FOLLOW-UP; FEMORAL-HEAD; TOTAL JOINT; PENETRATION; OSTEOLYSIS; ALUMINA; SURFACE;
D O I
10.1016/j.arth.2009.05.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To investigate the clinical results of cross-linked polyethylene (CLPE) and to compare the CLPE wear against zirconia and stainless steel heads, we studied the radiographic wear after a minimum 3-year follow-up in total hip arthroplasty (THA). Ninety-four hips were randomly implanted with a 22.225-mm head cemented THA-the group of non-CLPE against zirconia and CLPE against 2 different zirconias and stainless steel. The linear wear rate was significantly lower in the group of CLPE against zirconia (0.067, 0.059 mm/y) and against stainless steel (0.068 mm/y) compared with non-CLPE against zirconia (0.170 mm/y). in the short-term results, the wear performance of CLPE against zirconia was superior to that of non-CLPE; however, it did not show a better wear rate than CLPE against stainless steel. Furthermore, long-term investigations will be necessary for understanding CLPE wear in vivo.
引用
收藏
页码:1216 / 1220
页数:5
相关论文
共 50 条
  • [21] Cross-Linked Polyethylene in Total Knee Arthroplasty
    Rodriguez, Jose A.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 31 - 34
  • [22] Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty A 10-Year Double-Blinded Randomized Controlled Trial
    Devane, Peter A.
    Horne, James Geoffrey
    Ashmore, Alexander
    Mutimer, Jonathon
    Kim, Woosung
    Stanley, James
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20) : 1703 - 1714
  • [23] Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
    Campbell, David
    Mercer, Graham
    Nilsson, Kjell-Gunnar
    Wells, Vanessa
    Field, John R.
    Callary, Stuart A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01) : 23 - 27
  • [24] Long-Term Survivorship of Total Hip Arthroplasty with Highly Cross-Linked Polyethylene for Osteonecrosis
    Hart, Adam
    Janz, Viktor
    Trousdale, Robert T.
    Sierra, Rafael J.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (17) : 1563 - 1568
  • [25] The Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Replacement Is Not Increased by Large Articulations A Randomized Controlled Trial
    Howie, Donald W.
    Holubowycz, Oksana T.
    Callary, Stuart A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (21) : 1786 - 1793
  • [26] A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners
    Engh, C. Anderson, Jr.
    Stepniewski, Adam S.
    Ginn, Stuart D.
    Beykirch, Sarah E.
    Sychterz-Terefenko, Christi J.
    Hopper, Robert H., Jr.
    Engh, Charles A.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (06) : 17 - 25
  • [27] Early failure of a highly cross-linked polyethylene inlay after total hip arthroplasty probably due to insufficient irradiation
    Wahl, Peter
    Mossu-Haas, Christine
    Dommann-Scherrer, Corina
    Wei, Kongchang
    Eschbach, Lukas
    Gehr, Peter
    Benninger, Emanuel
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (12) : 1711 - 1719
  • [28] Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners
    Hopper, RH
    Young, AM
    Orishimo, KF
    McAuley, JP
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07) : 60 - 67
  • [29] Total hip arthroplasty using highly cross-linked polyethylene in patients aged 50 years and younger
    Roedel, G. G.
    Kildow, B. J.
    Sveom, D. S.
    Garvin, K. L.
    BONE & JOINT JOURNAL, 2021, 103B (07) : 78 - 83
  • [30] Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial
    Scemama, Caroline
    Anract, Philippe
    Dumaine, Valerie
    Babinet, Antoine
    Courpied, Jean Pierre
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (06) : 1113 - 1118