Preparation of Au-polydopamine functionalized carbon encapsulated Fe3O4 magnetic nanocomposites and their application for ultrasensitive detection of carcinoembryonic antigen

被引:26
作者
Ji, Lei [1 ]
Yan, Tao [1 ]
Li, Yan [1 ]
Gao, Jian [1 ]
Wang, Qi [2 ]
Hu, Lihua [1 ]
Wu, Dan [1 ]
Wei, Qin [1 ]
Du, Bin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Key Lab Chem Sensing & Anal Univ Shandong, Jinan 250022, Peoples R China
[2] Univ Jinan, Sch Mat Sci & Engn, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
TUMOR-MARKER; NANOPARTICLES; CEA; IMMUNOSENSOR; POLYMERS; GRAPHENE; REMOVAL;
D O I
10.1038/srep21017
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A novel carbon encapsulated Fe3O4 nanoparticles embedded in two-dimensional (2D) porous graphitic carbon nanocomposites (Fe3O4@C@PGC nanocomposites) were synthesized by situ synthesis strategy, which provided a sensor platform owing to a large aspect ratio and porous structure. Polydopamine (PDA) were modified on the surface of Fe3O4@C@PGC nanocomposites through self- polymerization of dopamine, acting as both the reductant and template for one-step synthesis of gold nanoparticles. The prepared Au/PDA/Fe3O4@C@PGC nanocomposites show ferromagnetic features, extremely excellent electron transfer, large specific surface area and excellent dispersing property. These are conducive to the electrochemical signal output and the immobilization of antibody. In this work, a highly label- free sensitive magnetic immunosensor was developed based on Au/PDA/Fe3O4@C@PGC nanocomposites for the detection of carcino- embryonic antigen (CEA). The magnetic glassy carbon electrode was used to fix the Au/PDA/Fe3O4@C@PGC nanocomposites with the help of magnetic force. Under the optimal conditions, the immunosensor exhibited a wide linear range (0.001 ng/mL-20.0 ng/mL), a low detection limit (0.33 pg/mL), good reproducibility, selectivity and acceptable stability. The proposed sensing strategy may provide a potential application in the detection of other cancer biomarkers.
引用
收藏
页数:7
相关论文
共 22 条
[21]   Capillary electrophoresis-chemiluminescence detection for carcino-embryonic antigen based on aptamer/graphene oxide structure [J].
Zhou, Zi-Ming ;
Feng, Zhe ;
Zhou, Jun ;
Fang, Bi-Yun ;
Qi, Xiao-Xiao ;
Ma, Zhi-Ya ;
Liu, Bo ;
Zhao, Yuan-Di ;
Hu, Xue-Bin .
BIOSENSORS & BIOELECTRONICS, 2015, 64 :493-498
[22]   Carcino-embryonic antigen detection based on fluorescence resonance energy transfer between quantum dots and graphene oxide [J].
Zhou, Zi-Ming ;
Zhou, Jun ;
Chen, Jun ;
Yu, Rong-Na ;
Zhang, Ming-Zhen ;
Song, Ji-Tao ;
Zhao, Yuan-Di .
BIOSENSORS & BIOELECTRONICS, 2014, 59 :397-403