Dose to Radiosensitive Organs During Routine Chest CT: Effects of Tube Current Modulation

被引:68
作者
Angel, Erin [1 ,2 ]
Yaghmai, Nazanin [1 ,2 ]
Jude, Cecilia Matilda [1 ,2 ]
DeMarco, John J. [1 ,2 ]
Cagnon, Christopher H. [1 ,2 ]
Goldin, Jonathan G. [1 ,2 ]
McCollough, Cynthia H. [3 ]
Primak, Andrew N. [3 ]
Cody, Dianna D. [4 ]
Stevens, Donna M. [4 ]
McNitt-Gray, Michael F. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90095 USA
[3] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
[4] Univ Texas MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
关键词
CT; Monte Carlo simulation; radiation dose; tube current modulation; voxelized patient model; MONTE-CARLO SIMULATIONS; RADIATION-EXPOSURE; FEMALE BREAST; COMPUTED-TOMOGRAPHY; REDUCTION; PROTOCOL; ABDOMEN;
D O I
10.2214/AJR.09.2886
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS. Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS. The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION. The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.
引用
收藏
页码:1340 / 1345
页数:6
相关论文
共 33 条
  • [21] Radiation exposure at chest CT:: A statement of the Fleischner Society
    Mayo, JR
    Aldrich, J
    Müller, NL
    [J]. RADIOLOGY, 2003, 228 (01) : 15 - 21
  • [22] CT dose reduction and dose management tools: Overview of available options
    McCollough, Cynthia H.
    Bruesewitz, Michael R.
    Kofler, James M., Jr.
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 503 - U14
  • [23] MEDICAL RADIATION EXPOSURE IN THE US IN 2006: PRELIMINARY RESULTS
    Mettler, Fred A., Jr.
    Thorriadsen, Bruce R.
    Bhargavan, Mythreyi
    Gilley, Debbie B.
    Gray, Joel E.
    Lipoti, Jill A.
    McCrohan, John
    Yoshizurrli, Terry T.
    Mahesh, Mahadevappa
    [J]. HEALTH PHYSICS, 2008, 95 (05): : 502 - 507
  • [24] Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
    Mulkens, TH
    Bellinck, P
    Baeyaert, M
    Ghysen, D
    Van Dijck, X
    Mussen, E
    Venstermans, C
    Termote, JL
    [J]. RADIOLOGY, 2005, 237 (01) : 213 - 223
  • [25] Female breast radiation exposure during CT pulmonary angiography
    Parker, MS
    Hui, FK
    Camacho, MA
    Chung, JK
    Broga, DW
    Sethi, NN
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (05) : 1228 - 1233
  • [26] Solid cancer incidence in atomic bomb survivors: 1958-1998
    Preston, D. L.
    Ron, E.
    Tokuoka, S.
    Funamoto, S.
    Nishi, N.
    Soda, M.
    Mabuchi, K.
    Kodama, K.
    [J]. RADIATION RESEARCH, 2007, 168 (01) : 1 - 64
  • [27] Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    Rizzo, S
    Kalra, M
    Schmidt, B
    Dalal, T
    Suess, C
    Flohr, T
    Blake, M
    Saini, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 673 - 679
  • [28] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334
  • [29] Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography
    Tran, LN
    Brown, MS
    Goldin, JG
    Yan, XH
    Pais, RC
    McNitt-Gray, MF
    Gjertson, D
    Rogers, SR
    Aberle, DR
    [J]. ACADEMIC RADIOLOGY, 2004, 11 (12) : 1355 - 1360
  • [30] TURNER A, 2008, COMP ORGAN DOSE 64