Potential of a simplified measurement scheme and device structure for a low cost label-free point-of-care capacitive biosensor

被引:51
作者
de Vasconcelos, Elder A. [2 ]
Peres, Newton G. [1 ]
Pereira, Cintya O. [1 ]
da Silva, Valdinete L. [3 ]
da Silva, Eronides F., Jr. [2 ]
Dutra, Rosa F. [1 ]
机构
[1] Univ Fed Pernambuco, PROCAPE, LAPED, BR-50100130 Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Fis, BR-50100130 Recife, PE, Brazil
[3] Univ Fed Pernambuco, Dept Engn Quim, BR-50740521 Recife, PE, Brazil
关键词
Label-free; Point-of-care; Capacitive immunosensor; Troponin; Acute myocardial infarction; Immunoglobulin; CARDIAC TROPONIN-T; QUARTZ-CRYSTAL MICROBALANCE; MYOCARDIAL-INFARCTION; IMMUNOSENSOR; SURFACE; PROTEIN; IMMOBILIZATION; TECHNOLOGIES;
D O I
10.1016/j.bios.2009.08.050
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simplified measurement scheme and device structure aiming at developing a low cost, label-free, point-of-care capacitive biosensor were investigated. The detection principle is the increase of low frequency capacitance between two planar Al electrodes observed after antibody-antigen interaction. The electrodes, deposited on oxidized Si wafers, were covered with an antibody layer, with and without using self-assembled thiol monolayer. Immunoglobulin G (IgG) and cardiac troponin T (TnT) were used as analytes to asses this proposal. The device was able to detect successfully TnT levels in the range 0.07 to 6.83 ng/mL in human serum from patients with cardiac diseases and in the range 0.01 ng/mL to 5 ng/mL for TnT in phosphate buffer saline. An equivalent circuit model able to reproduce the general behavior of experimental capacitance versus frequency curves was presented. The investigated features that have potential to reduce costs and simplify measurements were: use of single, low frequency (1 kHz) measurement signal, within the range of low cost portable capacitance meters; employment of a lower cost electrode material, aluminum, instead of gold electrodes; and use of simple and miniaturized planar two-electrodes arrangement, thus making a portable system for point-of-care applications. Published by Elsevier B.V.
引用
收藏
页码:870 / 876
页数:7
相关论文
共 19 条
[1]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[2]   Single Conducting Polymer Nanowire Chemiresistive Label-Free Immunosensor for Cancer Biomarker [J].
Bangar, Mangesh A. ;
Shirale, Dhammanand J. ;
Chen, Wilfred ;
Myung, Nosang V. ;
Mulchandani, Ashok .
ANALYTICAL CHEMISTRY, 2009, 81 (06) :2168-2175
[3]   Covalent immobilization of antibodies on finally inert support surfaces through their surface regions having the highest densities in carboxyl groups [J].
Batalla, Pilar ;
Fuentes, Manuel ;
Mateo, Cesar ;
Grazu, Valeria ;
Fernandez-Lafuente, Roberto ;
Guisan, Jose M. .
BIOMACROMOLECULES, 2008, 9 (08) :2230-2236
[4]   Looking towards label-free biomolecular interaction analysis in a high-throughput format: a review of new surface plasmon resonance technologies [J].
Boozer, Christina ;
Kim, Gibum ;
Cong, Shuxin ;
Guan, HannWen ;
Londergan, Timothy .
CURRENT OPINION IN BIOTECHNOLOGY, 2006, 17 (04) :400-405
[5]   Cardiac troponins in intensive care [J].
Collinson, P ;
Gaze, D .
CRITICAL CARE, 2005, 9 (04) :345-346
[6]   Surface plasmon resonance immunosensor for human cardiac troponin T based on self-assembled monolayer [J].
Dutra, Rosa Fireman ;
Mendes, Renata Kelly ;
da Silva, Valdinete Lins ;
Kubota, Lauro Tatsuo .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1744-1750
[7]   An SPR immunosensor for human cardiac troponin T using specific binding avidin to biotin at carboxymethyldextran-modified gold chip [J].
Dutra, Rosa Fireman ;
Kubota, Lauro Tatsuo .
CLINICA CHIMICA ACTA, 2007, 376 (1-2) :114-120
[8]   Sensitive optical biosensors for unlabeled targets: A review [J].
Fan, Xudong ;
White, Ian M. ;
Shopova, Siyka I. ;
Zhu, Hongying ;
Suter, Jonathan D. ;
Sun, Yuze .
ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) :8-26
[9]  
Janeway AC TP., 2005, Immunobiology: The immune system in health and disase
[10]  
Janshoff Andreas, 2005, V305, P47