Validation of radiologists' findings by computer-aided detection (CAD) software in breast cancer detection with automated 3D breast ultrasound: a concept study in implementation of artificial intelligence software

被引:21
作者
van Zelst, Jan C. M. [1 ]
Tan, Tao [1 ]
Mann, Ritse M. [1 ]
Karssemeijer, Nico [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol & Nucl Med, Route 766,Geert Grootepl 10, NL-6525 GA Nijmegen, Netherlands
关键词
Breast; neoplasm; ultrasound; artificial intelligence; computer-aided detection; screening; DENSE BREASTS; SCREENING MAMMOGRAPHY; WOMEN; PERFORMANCE; US; FEATURES; RISK; CLASSIFICATION; POPULATION; LESIONS;
D O I
10.1177/0284185119858051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Computer-aided detection software for automated breast ultrasound has been shown to have potential in improving the accuracy of radiologists. Alternative ways of implementing computer-aided detection, such as independent validation or preselecting suspicious cases, might also improve radiologists' accuracy. Purpose To investigate the effect of using computer-aided detection software to improve the performance of radiologists by validating findings reported by radiologists during screening with automated breast ultrasound. Material and Methods Unilateral automated breast ultrasound exams were performed in 120 women with dense breasts that included 60 randomly selected normal exams, 30 exams with benign lesions, and 30 malignant cases (20 mammography-negative). Eight radiologists were instructed to detect breast cancer and rate lesions using BI-RADS and level-of-suspiciousness scores. Computer-aided detection software was used to check the validity of radiologists' findings. Findings found negative by computer-aided detection were not included in the readers' performance analysis; however, the nature of these findings were further analyzed. The area under the curve and the partial area under the curve for an interval in the range of 80%-100% specificity before and after validation of computer-aided detection were compared. Sensitivity was computed for all readers at a simulation of 90% specificity. Results Partial AUC improved significantly from 0.126 (95% confidence interval [CI] = 0.098-0.153) to 0.142 (95% CI = 0.115-0.169) (P = 0.037) after computer-aided detection rejected mostly benign lesions and normal tissue scored BI-RADS 3 or 4. The full areas under the curve (0.823 vs. 0.833, respectively) were not significantly different (P = 0.743). Four cancers detected by readers were completely missed by computer-aided detection and four other cancers were detected by both readers and computer-aided detection but falsely rejected due to technical limitations of our implementation of computer-aided detection validation. In this study, validation of computer-aided detection discarded 42.6% of findings that were scored BI-RADS >= 3 by the radiologists, of which 85.5% were non-malignant findings. Conclusion Validation of radiologists' findings using computer-aided detection software for automated breast ultrasound has the potential to improve the performance of radiologists. Validation of computer-aided detection might be an efficient tool for double-reading strategies by limiting the amount of discordant cases needed to be double-read.
引用
收藏
页码:312 / 320
页数:9
相关论文
共 36 条
[1]   Recall rate of screening ultrasound with automated breast volumetric scanning (ABVS) in women with dense breasts: a first quarter experience [J].
Arleo, Elizabeth Kagan ;
Saleh, Marwa ;
Ionescu, Dana ;
Drotman, Michele ;
Min, Robert J. ;
Hentel, Keith .
CLINICAL IMAGING, 2014, 38 (04) :439-444
[2]   Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Cormack, Jean B. ;
Mendelson, Ellen B. ;
Lehrer, Daniel ;
Bohm-Velez, Marcela ;
Pisano, Etta D. ;
Jong, Roberta A. ;
Evans, W. Phil ;
Morton, Marilyn J. ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Barr, Richard G. ;
Farria, Dione M. ;
Marques, Helga S. ;
Boparai, Karan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (18) :2151-2163
[3]   Operator dependence of physician-performed whole-breast US: Lesion detection and characterization [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Cormack, Jean B. ;
Mendelson, Ellen B. .
RADIOLOGY, 2006, 241 (02) :355-365
[4]   Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666 [J].
Berg, Wendie A. ;
Bandos, Andriy I. ;
Mendelson, Ellen B. ;
Lehrer, Daniel ;
Jong, Roberta A. ;
Pisano, Etta D. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2016, 108 (04)
[5]   Assessing Improvement in Detection of Breast Cancer with Three-dimensional Automated Breast US in Women with Dense Breast Tissue: The Somoinsight Study [J].
Brem, Rachel F. ;
Tabar, Laszlo ;
Duffy, Stephen W. ;
Inciardi, Marc F. ;
Guingrich, Jessica A. ;
Hashimoto, Beverly E. ;
Lander, Marla R. ;
Lapidus, Robert L. ;
Peterson, Mary Kay ;
Rapelyea, Jocelyn A. ;
Roux, Susan ;
Schilling, Kathy J. ;
Shah, Biren A. ;
Torrente, Jessica ;
Wynn, Ralph T. ;
Miller, Dave P. .
RADIOLOGY, 2015, 274 (03) :663-673
[6]   The impact of mammographic screening on breast cancer mortality in Europe: a review of observational studies [J].
Broeders, Mireille ;
Moss, Sue ;
Nystrom, Lennarth ;
Njor, Sisse ;
Jonsson, Hakan ;
Poop, Ellen ;
Massat, Nathalie ;
Duffy, Stephen ;
Lynge, Elsebeth ;
Paci, Eugenio .
JOURNAL OF MEDICAL SCREENING, 2012, 19 :14-25
[7]   Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations [J].
Choi, Woo Jung ;
Cha, Joo Hee ;
Kim, Hak Hee ;
Shin, Hee Jung ;
Kim, Hyunji ;
Chae, Eun Young ;
Hong, Min Ji .
ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (21) :9101-9105
[8]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[9]   Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts [J].
Drukker, Karen ;
Sennett, Charlene A. ;
Giger, Maryellen L. .
MEDICAL PHYSICS, 2014, 41 (01)
[10]   Influence of computer-aided detection on performance of screening mammography [J].
Fenton, Joshua J. ;
Taplin, Stephen H. ;
Carney, Patricia A. ;
Abraham, Linn ;
Sickles, Edward A. ;
D'Orsi, Carl ;
Berns, Eric A. ;
Cutter, Gary ;
Hendrick, R. Edward ;
Barlow, William E. ;
Elmore, Joann G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (14) :1399-1409