Unbiased statistical image reconstruction in low-dose CT

被引:4
作者
Hayes, John [1 ]
Zhang, Ran [1 ]
Zhang, Chengzhu [1 ]
Gomez-Cardona, Daniel [1 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
来源
MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING | 2019年 / 10948卷
关键词
Low-dose CT; quantitative accuracy; CT number bias; model based iterative reconstruction;
D O I
10.1117/12.2512848
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When x-ray exposure level is lowered in the attempt to reduce radiation dose in x-ray computed tomography (CT), noise level is elevated. While this is well known in the community, less attention has been paid to another critically important fact in low dose CT: the accuracy of CT number is also compromised. Namely, CT numbers for some organs are increased while the CT number may be decreased in some other organs. The application of denoising methods can reduce noise level, but the denoising method, generally speaking, does not reduce the CT number biases. This has been shown in systematic experimental studies using clinically available reconstruction methods such as the conventional filtered backprojection or the statistical model based image reconstruction method. Although it has been known that the bias can be eliminated in statistical reconstruction if the Poisson log-likelihood function is not approximated by its quadratic form, the computation cost is quite expensive and thus these types of methods are not used in currently available commercial CT products. In this paper, we present an innovative way to design the statistical weighting function to enable unbiased statistical reconstruction with a quadratic data fidelity term and a regularizer.
引用
收藏
页数:6
相关论文
共 7 条
  • [1] Ordered subsets algorithms for transmission tomography
    Erdogan, H
    Fessler, JA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) : 2835 - 2851
  • [2] HYBRID POISSON POLYNOMIAL OBJECTIVE FUNCTIONS FOR TOMOGRAPHIC IMAGE-RECONSTRUCTION FROM TRANSMISSION SCANS
    FESSLER, JA
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (10) : 1439 - 1450
  • [3] Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction
    Garrett, John W.
    Li, Yinsheng
    Li, Ke
    Chen, Guang-Hong
    [J]. MEDICAL PHYSICS, 2018, 45 (05) : 2009 - 2022
  • [4] Kak AvinashC., 2001, CLASSICS APPL MATH, V33
  • [5] Li Y., 2014, P SOC PHOTO-OPT INS, V9033
  • [6] Noise weighting with an exponent for transmission CT
    Zeng, Gengsheng L.
    Wang, Wenli
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (04):
  • [7] Quantitative accuracy of CT numbers: Theoretical analyses and experimental studies
    Zhang, Ran
    Cruz-Bastida, Juan P.
    Gomez-Cardona, Daniel
    Hayes, John W.
    Li, Ke
    Chen, Guang-Hong
    [J]. MEDICAL PHYSICS, 2018, 45 (10) : 4519 - 4528