Hands-free speech after surgical voice rehabilitation with a Provox® voice prosthesis:: experience with the Provox FreeHands HME tracheostoma valve® system

被引:18
|
作者
Lorenz, K. J.
Groll, K.
Ackerstaff, A. H.
Hilgers, F. J. M.
Maier, H.
机构
[1] German Armed Forces Hosp, Dept Otolaryngol Head & Neck Surg, D-89081 Ulm, Germany
[2] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Univ Amsterdam, Ctr Language & Commun, Inst Phonet Sci Amsterdam, NL-1012 WX Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, NL-1012 WX Amsterdam, Netherlands
关键词
voice prostheses; hands-free speech; tracheostoma valves; voice rehabilitation;
D O I
10.1007/s00405-006-0155-2
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Excellent results have been reported with the use of voice prostheses for the rehabilitation of laryngectomees. Patients, however, consider it a disadvantage that the tracheostoma must be closed manually for speech production. This limits their ability to simultaneously communicate by gesture or to work with both hands. An automatic tracheostoma valve helps patients overcome this problem. We describe a prospective clinical trial evaluating our experience with the Provox FreeHands HME Automatic Tracheostoma Valve((R)) system. Twenty-four laryngectomees were randomly selected from the patients who had undergone laryngectomy at the ENT Department. Immediately, after 4 weeks and 6 months later having been fitted with a Provox FreeHands HME (R), the patients were asked to complete a questionnaire in order to assess their satisfaction, voice quality, wearing comfort, fixation, potential problems, and the effectiveness of the HME cassette. In addition, we investigated relevant voice quality parameters including dynamics range, frequency range of the speaking voice, and maximum phonation time. Seven patients discontinued the study due to problems of securing the valve to the skin (four patients) or recurrent cancer (three patients). Ten of the remaining 17 patients wore the valve daily for an average of 8.4 h. A total of 88% of the patients considered it a great advantage to be able to speak without having to use their hands. With the Provox FreeHands HME (R), maximum phonation time was 8.7 (+/- 6.2) s and the dynamic range was 21.9 (+/- 5.8) decibels. The results show that the Provox FreeHands HME Automatic Tracheostoma Valve((R)) system not only allows hands-free speech but is also associated with excellent compliance and good voice rehabilitation.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 9 条