Function and accuracy of glucose sensors beyond their stated expiry date

被引:14
作者
Chlup, Rudolf [1 ]
Jelenova, Daniela
Chlupova, Karolina
Zapletalova, Jana
Chlupova, Ludmila
Bartek, Josef
机构
[1] Palacky Univ, Fac Med, Inst Physiol, Olomouc 77900, Czech Republic
[2] Palacky Univ, Fac Med, Inst Pathophysiol, Olomouc 77900, Czech Republic
[3] Palacky Univ, Fac Med, Inst Biophys, Olomouc 77900, Czech Republic
[4] Palacky Univ, Fac Med, Inst Med Chem & Biochem, Olomouc 77900, Czech Republic
[5] Palacky Univ, Fac Med, Dept Med 2, Olomouc 77900, Czech Republic
[6] Palacky Univ, Pedag Fac, Dept Special Educ, Olomouc 77900, Czech Republic
[7] Cent Inst Diabet Gerhardt Katsch, D-2201 Karlsburg, Germany
关键词
D O I
10.1089/dia.2006.8.495
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The sensor of the Continuous Glucose Monitoring System (CGMS(TM), Medtronic Minimed, Northridge, CA) is labeled to expire 6 months following its production and to measure the glucose concentration in interstitial fluid up to 3 days after insertion. The purpose of this study was to demonstrate potential possibilities of sensors when used beyond their expiry date. Methods: Twenty sensors, each between 3 to 18 months after the expiry date, were assessed in a 7-day period after insertion. Twenty healthy volunteers 23.4 +/- 2.92 (mean +/- SD) years old were trained in handling the CGMS and the Hypoguard (Woodbridge, UK) Advance(TM) glucometer system to measure their capillary plasma glucose concentration 18 times a day. Sensor function was estimated according to the number of readings per day, the accuracy according to the mean absolute difference (MAD), and correlation coefficient (r) between glucometer and sensor resulting from paired values. Results: Uninterrupted sensor function was found in 117 of 140 sensor-days (83.6%). A reduction of readings in 23 sensor-days (16.4%) was caused by user error (5 sensor-days, 3.6%), connecting cable (7 sensor-days, 5%), sensor failure (8 sensor-days, 5.7%), or uncertain factors (3 sensor-days, 2.1%). MAD was always <28%, and r = 0.79. Conclusions: Neither the expiry date nor the 3-day period of use limits the reliable function of a CGMS sensor. Sensors were found to function as long as 18 months after the expiry date, mostly for at least 7 days. There were no serious local adverse reactions. Prolongation of shelf-life label and insertion time appears to be reasonable. Further studies are in progress.
引用
收藏
页码:495 / 504
页数:10
相关论文
共 25 条
  • [1] [Anonymous], **NON-TRADITIONAL**, DOI DOI 10.1089/15209150050214087
  • [2] Bode B W, 2000, Diabetes Technol Ther, V2 Suppl 1, pS35
  • [3] Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study
    Bode, BW
    Gross, TM
    Thornton, KR
    Mastrototaro, JJ
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1999, 46 (03) : 183 - 190
  • [4] Limitations of conventional methods of self-monitoring of blood glucose - Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes
    Boland, E
    Monsod, T
    Delucia, M
    Brandt, CA
    Fernando, S
    Tamborlane, WV
    [J]. DIABETES CARE, 2001, 24 (11) : 1858 - 1862
  • [5] BROZ J, 2002, DIABETES, V45, P480
  • [6] Buckingham B, 2004, DIABETOLOGIA, V47, pA93
  • [7] Buckingham Bruce, 2005, Diabetes Technol Ther, V7, P792, DOI 10.1089/dia.2005.7.792
  • [8] Continuous glucose monitoring a novel approach to the determination of the glycaemic index of foods (DEGIF 1) -: Determination of the glycaemic index of foods by means of the CGMS
    Chlup, R
    Jelenová, D
    Kudlová, P
    Chlupová, K
    Bartek, J
    Zapletalová, J
    Langová, K
    Chlupová, L
    [J]. EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2006, 114 (02) : 68 - 74
  • [9] Chlup R, 2005, DIABETES, V54, pA138
  • [10] Chlup Rudolf, 2005, Biomedical Papers (Olomouc), V149, P127